Define conductor
A metallic conduit which allows electrons to flow
Define insulator
Covering of the conductor to impede the flow of electrons
What is the difference between direct current (DC) and alternating current (AC)?
Direct current is the flow of electrons in one direction
Alternating current is the flow of electrons that reverses its direction at regularly recurring intervals
Define hertz
A measure of frequency per second, specifically for alternating current
Explain the difference between a voltage, an ampere, a watt, and an ohm
Voltage is a measure of electrical pressure
Ampere is a measure of electrical current or flow rate
Ohm is a measure of electrical resistance
Watt is the measure of electrical power being used
Explain the use of a contactor and a relay
The relay controls the movement of the contact to physically open or close circuits, turning on or off power
Define a bus
A heavy duty conductor that distributes electricity to several circuits
What is the purpose of a circuit breaker?
It is a protection measure against overcurrent by popping out the circuit and shutting off power supply. Can be reused after correcting the fault.
What is the purpose of current limiters?
It is a protection measure against overcurrent by blowing the current limiter and shutting off power supply when exceeded. Must be replaced after correcting the fault.
What is the purpose of a auto-transformer?
It converts AC power from a higher voltage to a lower voltage, specifically 115 VAC to 26 VAC in the UH-60
What is the purpose of a generator?
It converts mechanical energy to electrical energy
What is the purpose of a battery?
It stores electricity chemically
What is the purpose of a converter?
It converts 115 VAC 3-phase power into 28 VDC 400 amps power
What is the priority of AC power in the UH-60?
Main generators
APU generator
External power
Explain the main generators
Two oil cooled, brushless generators mounted on the accessory modules
Driven by the main rotor above 85% in flight, and above 93-97% on the ground
115/200 VAC 3 phase 400 Hz with a capacity of 30/45 or 40/60 KVA
Explain the three position main generator switch
Forward=On=Generator energized and permits connection of AC output to the AC loads
Center=Off/Reset=De-energizes the generator and permits recycling if disconnecting from its load
Aft=Test=Permits testing of the generator AC output via the GCU, which clears the GEN FAIL cautions if it passes
Explain the functions of the Generator Control Unit (GCU)
Voltage regulation to 115/200 VAC
Over Voltage protection at 125 VAC
Under Voltage protection at 100 ± 5 Hz (85% NR)
Current limiting to protect against excessive current demands placed on the generator
Under Frequency protection at 375 ± 5 Hz (93-95% NR), but is disabled in flight by the right WOW switch
Feeder fault to disconnect the system when a short circuit is present between the generator terminals and the AC primary buses
What additional bus does the #1 generator provide power for?
AC Reference bus
Explain the main generator bearing’s limitations
Auxiliary bearing provides additional 10 flight hours after the primary bearing has failed
When the GEN BRG FAIL caution appears for more than 1 minute, make an entry on DA Form 2408-13-1 to notify maintenance
Explain the APU generator
AC power source that provides electrical power for ground operations and in-flight emergencies
Mounted to and driven by the APU accessory gearbox
115/200 VAC 3 phase 400 Hz with a capacity of 20/23.8 KVA
The APU can provide electrical power for all systems except these two simultaneously and which has priority?
Back-up hydraulic pump and Windshield anti-ice
Back-up hydraulic pump has priority
When does the APU GEN ON advisory appear?
When the APU is the sole source of AC power
Explain the external power receptacle
Permits connection of an external AC 115 VAC, 3 phase, 400 Hz power source to the helicopter during ground operations
Explain the external power monitor panel
On the right interior of the cabin below the crew-chief window
Checks for five conditions before applying external power
Over voltage
Under voltage
Over frequency
Under frequency
Proper phase rotation
Explain the #1 Junction Box
#1 Generator current transformer T13
#1 Generator line contactor K1
Current Limiters CL4,5,6
Remote circuit breaker CB404
Back-up Hydraluic pump relay K19
Auto-transformer T-12
Explain the #2 Junction Box
#2 Generator current transformer T2
#2 Generator line contactor K2
APU generator transformer T3
APU external power contactor K3
AC Bus tie contactor K4
Current limits CL1,2,3
#2 test receptacle
APU test receptacle
Explain the auto-transformers T-115 and T-12
T-115 converts 115 VAC B phase power from the #1 AC PRI BUS to 26 VAC for the AC REF BUS XFR relay K13
T-12 converts 115 VAC B phase power from the #2 AC PRI BUS to 26 VAC for back-up AC REF BUS power
T-115 is located between the main transmission and IVHMU, while T-12 is located in the #1 Junction box
What is the sole responsibility of the AC Reference Bus?
Provide stabilator position indication
What does the AC REF BUS DEGRAD advisory indicate?
One or both of the T-115 and T-12 auto transformers has failed physically or lost AC power
What is the priority of DC power?
DC converters
SLABs
Explain the DC converters
Converts 115 VAC 3 phase power to 28 VDC 400 amps
One converter has the ability to power the entire DC system
Which buses can only be powered by the DC converters?
#1 and #1 DC Primary buses
Explain the abilities of the two SLABs
Provides 24 VDC 5 amp hours power
Provides power to its respective battery utility bus when plugged in
Provides power to both sides essential and battery buses when battery switch is on
Explain the emergency power function of the batteries
Provides approximately 12 minutes of uninterrupted power to essential systems including
ICS
Transponder
#3 MFD
#2 EGI, DCU, and ADC
Radar altimeter
#1 Stabilator actuator
VOR/ILS
#1 VHF
Explain the Test position and indications of the batteries
Places approximately 4 amp load on the respective battery
BATT GOOD indicates charged and remains above 21.5 VDC
BATT LOW appears if it is initially below 21.5 VDC or falls below 20.5 VDC
BATT LOW indication will not appear with the converters on
What happens when power is lost to the DC primary buses due to a dual generator or converter failure (No AC power)?
Both engine anti-ice valves will open
What does the DC ESS BUS FAIL cautions indicate?
No power is being supplied to the DC essential bus due to the battery switch not being on, and a subsequent loss of AC power