Scanning Electron Microscopy and Energy Dispersive X-Ray Spectroscopy

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/24

flashcard set

Earn XP

Description and Tags

Comprehensive review flashcards covering SEM instrumentation, interaction volumes, electron signals (SE and BSE), lens aberrations, and EDS quantitative elemental analysis.

25 Terms

1
New cards

The average distance an electron travels between scattering events in a specimen is known as the __________.

mean free path (λ\lambda)

2
New cards

A collision in which a beam electron transfers energy to an atom and causes it to become ionized is termed an __________ collision.

inelastic

3
New cards

The pear-shaped zone inside a sample representing where the electron beam scatters and loses energy is the __________.

interaction volume (IV)

4
New cards

In the Kanaya-Okayama range equation R=(0.0276)(A)(E1.67)Z0.89ρR = \frac{(0.0276)(A)(E^{1.67})}{Z^{0.89}\rho}, increasing the beam accelerating voltage (EE) causes the penetration depth to __________.

increase

5
New cards

The ratio of emitted secondary electron current to incident primary beam current is designated as the __________ (δ\delta).

secondary electron yield

6
New cards

Because backscattered electron yield (η\eta) increases with atomic number (ZZ), regions with a higher ZZ appear __________ in BSE imaging.

brighter

7
New cards

Secondary electrons provide surface topographic information because only SEs generated within an escape depth of less than __________ can escape.

50 eV50\,\text{eV}

8
New cards

In an SEM, magnification (Magnification=LmonitorLspecimen\text{Magnification} = \frac{L_{\text{monitor}}}{L_{\text{specimen}}}) is increased by __________ the scan area on the sample.

shrinking

9
New cards

The relative difference in signal intensity that defines image contrast (CC) is given by the formula C=__________C = \_\_\_\_\_\_\_\_\_\_.

I2−I1I1=ΔII1\frac{I_2 - I_1}{I_1} = \frac{\Delta I}{I_1}

10
New cards

According to the Rayleigh criterion, the diffraction-limited resolution is given by ρd=0.61⋅λα\rho_d = 0.61 \cdot \frac{\lambda}{\alpha}, where α\alpha represents the __________.

convergence angle

11
New cards

Overvoltage (U=E0EcU = \frac{E_0}{E_c}) must be at least U≥1U \ge 1 to excite characteristic X-rays, with an optimal range of __________ for strong peaks.

2–52\text{--}5

12
New cards

Of the three secondary electron classifications, __________ electrons provide the highest spatial resolution because they are generated right at the beam impact point.

SE1

13
New cards

Secondary electrons generated when backscattered electrons collide with the microscope chamber walls are designated as __________ electrons.

SE3

14
New cards

X-rays exhibit a much larger escape depth than electrons because X-rays are uncharged __________ that interact much more weakly with matter.

photons

15
New cards

In the SEM column, the electron source is demagnified into a smaller spot primarily by the __________ lens.

condenser

16
New cards

The smallest, sharpest possible spot size achievable in the presence of chromatic aberration is termed the __________.

disc of least confusion

17
New cards

Astigmatism elongates the electron probe into an ellipse and streaks the image, but it can be corrected using electromagnetic coils known as a __________.

stigmator

18
New cards

Continuum background X-rays originate deeper than characteristic X-rays because continuum emissions continue until electron energy reaches E→0E \rightarrow 0, whereas characteristic X-rays require E>__________E > \_\_\_\_\_\_\_\_\_\_.

EcE_c (critical excitation energy)

19
New cards

The characteristic X-ray range (RxR_x) setting the EDS spatial resolution is calculated as Rx=0.064ρ(__________)R_x = \frac{0.064}{\rho}(\_\_\_\_\_\_\_\_\_\_).

E01.68−Ec1.68E_0^{1.68} - E_c^{1.68}

20
New cards

In the characteristic X-ray yield expression NA=(nA⋅t)⋅σA⋅ωA⋅η⋅NeN_A = (n_A \cdot t) \cdot \sigma_A \cdot \omega_A \cdot \eta \cdot N_e, the term ωA\omega_A represents the __________.

fluorescence yield

21
New cards

Castaing's similar-standard method determines elemental concentration by assuming that the __________ in the NAN_A yield equation are equal for both the unknown and the standard.

proportionality constants

22
New cards

When ordering quantitative EDS methods from lowest to highest accuracy, the order is: standardless quantification < __________ < fully standardized quantitative analysis.

similar standard

23
New cards

In quantitative EDS matrix corrections, ZAF accounts for atomic number effects (ZZ), X-ray absorption (AA), and __________ (FF).

secondary fluorescence

24
New cards

To determine true net characteristic peak intensities in an EDS spectrum, __________ must be performed to eliminate the underlying continuum.

background subtraction

25
New cards
<p>In the provided SEM diagram, label 4 indicates the BSE detector positioned above the specimen, while label 5 indicates the __________ detector.</p>

In the provided SEM diagram, label 4 indicates the BSE detector positioned above the specimen, while label 5 indicates the __________ detector.

secondary electron (SE)