A ________ valve is typically used in speed control applications.
Needle
_________ valves are typically used for full-flow or no-flow operations and are not designed for restricting fluid flow.
Gate
Depending on the length of a rod, piston speed can be measured in _____ or _________.
fpm; ipm
Gate valves are used for applications with pressures of _______ psi to ________ psi.
2000-5000 psi
A ___________ system is typically used for applications that need to extend a heavy load but retract no load.
meter-In
Fluid flow must make two 90 degree turns to pass in one direction through a __________ valve.
globe
A double-acting cylinder can be metered by controlling piston speed on ________.
All of the above / Extending and restricting
A _________ valve has a disk that is raised or lowered over an orifice.
globe
On schematic diagrams, the bypass check valve arrow points __________ the cylinder for meter-In cylinders.
towards
A flow control valve and a check valve in reverse parallel with each other is also refereed to as a ____________.
flow control valve with a check or internal check
Ball valves can be rated as high as ________ psi.
12,000
When piston speed is too high, it can be corrected by using a ________ valve.
None of the above
__________ is the controlling of the rate of fluid flow and how the fluid flow is being accomplished.
Metering
To control the piston speed of a double-acting cylinder, a flow control valve with a check valve is used to control the flow rate at __________ of the cylinder.
the cap-end port or the rod-end port
The main variable that affects pressure differential in a hydraulic system is the _____________.
weight of the load
A meter-In system is used to control piston speed of a single-acting cylinder during __________.
extension
______________ systems are typically used in double-acting cylinders when an abrupt change from high pressure to low pressure may occur.
Meter-out
Fluid flow is usually metered in only one direction by using a flow control valve with a ______________.
check valve
Fluid flow takes a ________ turn through a flow control valve to create a pressure differential.
90 degree
A _________ cylinder uses fluid flow for extensions and a spring, gravity, or other mechanical means for retraction.
single-acting
A(n) __________ valve compensates for changes in hydraulic fluid temperature and pressure.
temperature and pressure compensated flow control
A ___________ cylinder has fluid pressure flow alternately on both sides of the cylinder to extend and retract the piston.
double-acting
Most flow control valves used in hydraulic systems are __________ valves.
needle
When calculating the piston speed of a cylinder with no load, the 2 variables that must be considered are _______ and ________.
flow rate; piston face area.
_________ is controlling of the rate of fluid flow.
Metering
A variable orifice in a flow control valve is also referred to as ________.
compensated flow control.
When a load on a double-acting cylinder remains constant, a meter-_________ systems has the most accurate speed control.
in
Some types of _____ valves have color-coded valve stems.
needle
____________ flow control valves operate by maintaining a constant pressure differential across the valve's orifice.
Pressure-compensated
A _______ valve is a two-position valve with an integral gate between the two seats of the orifice.
gate
When using meter-In flow control to control the speed of the piston during extension only, a flow control valve with check valve is placed between the DCV and the ______-end port of the cylinder.
cap
__________ is a type of flow control where a needle valve (no check) controls the flow of fluid to the reservoir in a parallel leg of the system to control the speed of an actuator.
Bleed-off
The most common method of compensating for changes in hydraulic fluid temperature is to use a flow control valve that has a(n) ________ through the path of fluid flow.
pointed bimetallic stem
The primary function of a(n) _______ valve is to control the rate of fluid flow.
flow control
If the load on a hydraulic cylinder is reduced, piston speed ________.
increases
T/F: Meter-In systems are used only for controlling piston speed.
F
T/F: Bleed-off systems are used when more flow control accuracy and less system efficiency are required.
F
T/F: To control the piston speed of a double-acting cylinder during retraction by using meter-In, a flow control valve is attached to the rod end of the cylinder.
T
T/F: Gate valves have ports that are the same size as the means of transmission.
T
T/F: Piston speed is not affected by the amount that an orifice in a flow control valve is open to allow fluid flow.
F
T/F: The metering of a double-acting and single-acting cylinder is performed differently.
T
T/F: Meter-In systems are more commonly used than meter-out systems in double-acting cylinders.
F
T/F: A variable orifice is a valve.
F
T/F: The difference between a meter-In system and a meter-out system on a double-acting cylinder is that the flow control valves must be reversed.
T
T/F: Gate valves can allow fluid flow in both directions, unless otherwise marked.
T
T/F: The greater the pressure differential across a needle valve, the less the flow rate through the valve.
F
T/F: A ball valve has a ball with an orifice through its center to allow fluid flow.
T
T/F: A bleed-off system uses a flow control valve without a check valve.
T
T/F: Gate valves are designed for low-pressure service, typically no higher than 150 psi.
F
T/F: Either port of a double-acting cylinder can function as an input or an output, depending on whether the cylinder is extending or retracting.
T
T/F: Meter-out is used in applications that require high accuracy unless pressure conditions do not allow such use.
F
T/F: Needle valves can have built-In check valves for applications that require fluid flow in the opposite direction of the needle valve's metered flow.
T
T/F: Bleed-off systems used for flow control have less efficiency than meter-In or meter-out systems.
F
T/F: Fluid flow can only be metered while using double-acting cylinder.
F
T/F: Bleed-off meters fluid flow to and from a cylinder by returning (bleeding-off) some of the hydraulic fluid to the reservoir.
T
T/F: An orifice is smaller than the inside diameter of a pipe, hose, tube, or internal passage.
T
T/F: All gate valves have a nonrising-stem design.
F
T/F: If the load on a cylinder increases, the pressure differential across the flow control valve decreases, and fluid flow out of the flow control valve also decreases.
T
T/F: Needle valves have an infinite number of positions for flow control.
T
T/F: A bleed-off system uses a flow control valve with a check valve as a bypass.
F