Essential vocabulary, fundamental laws, components, and concepts extracted from Power Plant and Industrial Engineering refresher modules.
Higher Heating Value (HHV)
The total heat released by the complete combustion of a unit of fuel when the water vapor produced during combustion is fully condensed to liquid.
Orsat Apparatus
A laboratory equipment used to analyze the volumetric composition of flue gases, specifically measuring CO2, O2, and CO.
Spinning Reserve
Unused generating backup capacity that is kept running, fully synchronized with the electrical grid, and ready to meet immediate load increases or compensate for sudden generation loss.
Load Factor
The ratio of the average load to the maximum demand over a specified operating period in power plant economics.
Exergy
The portion of energy that can be completely converted into useful work when brought to thermodynamic equilibrium with a reference environment.
Fourier's Law
A fundamental conduction law stating that conductive heat flux through a material is directly proportional to the negative temperature gradient.
Newton's Law of Cooling
The convective heat transfer law stating that the rate of heat loss from a body is directly proportional to the temperature difference between the surface and the surrounding fluid.
Biot Number
A dimensionless ratio comparing internal conduction resistance within a solid to the external convection resistance at its surface.
Dirichlet Condition
A boundary condition in thermal analysis that prescribes a constant surface temperature.
Cetane Number
A rating scale that quantifies the ignition quality and delay period of a diesel fuel upon injection.
Octane Number
A rating value indicating the anti-knock capability and resistance to premature detonation of a spark-ignition engine fuel.
Black Start
The process of restoring an electric power station to operation without relying on an external transmission network or electrical power supply.
Exhaust Gas Recirculation (EGR)
An engine emissions control technique that routes a portion of the exhaust gas back into the intake air to reduce peak combustion temperatures and minimize NOx emissions.
Megohmmeter (Megger)
An instrument designed to measure exceptionally high electrical insulation resistance of generator windings and electrical cables.
Economizer
A feedwater-heating auxiliary device that extracts residual heat from hot boiler flue gases before they exit to the stack.
Superheater
A tubular boiler component that increases steam temperature above its saturation temperature at constant pressure.
Fusible Plug
A safety relief device designed with a low-melting-point core that melts to prevent the furnace from overheating when boiler water drops below safe levels.
Run-of-River Plant
A hydroelectric power installation that produces electricity using the natural upstream flow of a river without having a storage reservoir.
Torricelli's Theorem
The fluid dynamics principle relating the flow velocity of a liquid issuing through an orifice directly to the liquid head above the opening (v=2gh).
Betz's Limit
The theoretical maximum aerodynamic efficiency for any wind turbine rotor, set at approximately 59.3%.
SCRAM
The rapid emergency shutdown of a nuclear fission reactor accomplished by the immediate full insertion of control rods.
Hoop Stress
The circumferential tensile stress generated perpendicular to the axis and radius in a thin-walled pipe or cylindrical shell by internal fluid pressure.
Hydrodynamic Lubrication
A lubrication regime in which moving surfaces are completely separated by a continuous, pressurized fluid lubricant film, preventing metal-to-metal contact.
Ringelmann Chart
A standard visual scale used to measure and classify the apparent density and opacity of smoke emissions from stacks.
Certificate of Non-Coverage (CNC)
A document issued by the DENR-EMB certifying that a proposed project is outside the scope of the Environmental Impact Statement (EIS) system and does not require an Environmental Compliance Certificate.
Lockout/Tagout (LOTO)
An industrial safety procedure that ensures machinery is completely de-energized, isolated from energy sources, and locked prior to servicing or maintenance.
Cavitation
The formation and rapid collapse of vapor bubbles in a liquid when local pressure drops below vapor pressure, causing pitting, noise, and erosion in pumps.
Net Positive Suction Head (NPSH)
The total energy head above the liquid vapor pressure required at pump suction to prevent vaporization and cavitation.
Cooling Range
The temperature difference between the hot water entering a cooling tower and the cold water leaving it.
Approach Temperature
The temperature difference between the cooled water leaving a cooling tower and the wet-bulb temperature of the ambient entering air.
Number of Transfer Units (NTU)
A dimensionless parameter that characterizes the thermal size and heat transfer capacity of a heat exchanger relative to the minimum heat capacity rate (NTU=CminUA).
Thermostatic Expansion Valve (TXV)
An automatic throttling device that meters refrigerant flow to the evaporator while maintaining a constant superheat at the evaporator outlet across varying loads.
Cooling Load Temperature Difference (CLTD)
An equivalent temperature difference value used in building cooling load calculations to account for both thermal mass delay and radiative solar effects through walls and roofs.
Respiration Load
The internal heat generation occurring in cold storage resulting from the ongoing metabolic activity of stored fresh fruits and vegetables.
Sensible Heat Factor (SHF)
The ratio of the sensible heat load to the total cooling load (the sum of sensible and latent heat loads) of a space.
Sling Psychrometer
A handheld psychrometric instrument consisting of a dry-bulb and a wetted-wick thermometer whirled in the air to measure dry-bulb and wet-bulb temperatures.
Equal Friction Method
A duct design sizing procedure that sizes air ducts based on maintaining a constant frictional pressure drop per unit length throughout the distribution system.
HEPA Filter
High-Efficiency Particulate Air filter designed to capture very fine sub-micron airborne particles, commonly required in clean rooms and sterile environments.
Phosgene
A highly toxic, poisonous gas (COCl2) formed when chlorinated fluorocarbon refrigerants (Freon) are exposed to high temperatures or open flames.