1/70
segemntal pressures of lower end and upper extremities
segmental pressure testing - lower extremities capabilities and limitations
presence/absence of disease
approx. level and severity
not exact location or stenosis vs occlusion
incompressible vessels. often seen in diabetics and end stage renal disease. pressures will be inaccurately high
medial calcinosis
pts with — cannot have segmental pressure testing
dialysis fistula, stents, DVT, or hx of lymphedema
— = must consult vascular surgeon before proceeding
any surgical modifications
techniques for systolic pressure testing
pt must be in basal state (resting for at least 20 minutes)
pt must be supine (no hydrostatic pressure)
— = 2 thighs, calf, ankle
4 cuff method
— = 1 large thigh, calf, ankle
3 cuff method
— brachial cuffs
bilateral
width of cuff = — diameter of limb
1.2x greater than
if cuff is too wide =
falsely low pressure
if cuff is too narrow =
falsely high pressure
obtaining systolic pressure:
use CW doppler to locate arterial pulse distally (ex-PTA or DPA)
inflate cuff to suprasystolic pressure (30 higher than last audible signal)
slowly deflate
record pressure when pulsation returns
pressures must be taken —
distal to proximal (ankle > calf > thigh)
use — of 2 ankle pressures on each leg to complete rest of study
higher
we are going to take pressures of the — at the level of the each ankle
PTA and DPA
interpretation of the segmental pressure
calculate ankle/brachial index (ABI)
ABI =
ankle pressure divided by HIGHEST brachial pressure
normal ankle pressures should be about — as the brachial
the same
in presence of arterial disease =
pressure drops
ankle < brachial indicates there is a disease. ABI would be —
<1.0
ankle > brachial would give an ABI of >1.0 =
no disease proximally
ABI > — indicates the vessels are likely incompressible = NOT accurate
1.3
ABI ± 1.0 =
normal
ankle > brachial = ABI — 1.0
>
ankle < brachial = ABI — 1.0
<
normal ABI
1.0
WNL/ minimal disease ABI
0.9-1.0
mild disease ABI
0.8-0.9
moderate disease (claudication) ABI
0.5-0.8
severe disease (rest pain) ABI
<0.5
pressures — abnormally distal to disease
DROP
compare thigh pressure to —
highest brachial
normal thigh pressure for 3 cuff method:
thigh should be same or higher than brachial
normal thigh pressure for 4 cuff method
high thigh should be 30 or more higher than highest brachial
look for drops of — or more between consecutive vertical levels
30
— difference between levels is NORMAL
<30
— drop means disease between those level
30 or more
an — in pressure is not significant !!!
increase
arterial obstructive disease will always — the pressures distally
decrease
— is when the thigh pressure is not 30 higher than the highest brachial pressure unilaterally
iliofemoral disease
— is when the thigh pressure is not 30 higher than the highest brachial pressure bilaterally
aortaliliac disease
purpose of exercise testing
produces physiologic stress on circulation and reproduces ischemia
exercise testing allows to distinguish between —
true and pseudo claudication
exercise testing contraindications :
difficulty walking or breathing, severe HTN, cardiac
exercise testing technique
constant load treadmill (unchanging)
<12% grade elevation and 1.5 mph for a max of 5 min
leave ankle cuffs on. after exercise, repeat ankle pressures
normal exercise testing
no change or increase in ankle pressures
abnormal exercise testing
decrease in ankle pressure
if exercise testing is abnormal then you have to
repeat ankle pressures every 2 minutes until they return to resting
if abnormal ankle pressures return to normal <6 min =
single level disease
if abnormal ankle pressures return to normal >6 min =
multilevel disease
for pts that cannot do treadmill
reactive hypermia
purpose of reactive hyperemia
produces ischemia and distal vasodilation. cutting off the flow forces the body to vasodilate. then when the cuff is released we see how the hypermia (increase in flow) reacts = how quickly it gets down
reactive hyperemia technique
inflate thigh cuff to suprasystolic pressures 3-5 min
release cuff adn record ankle pressures
normal reactive hyperemia test
transient drop in pressure that returns to resting within 1 minute (<34%)
abnormal reactive hyperemia testing
big drop in pressure
<50% drop in reactive hyperemia test =
single level disease
>50% drop in reactive hyperemia test =
multilevel disease
hyperemia is prolonged in the —
obstructed limb
segmental pressure testing - upper extremities technique
brachial cuff (obtain brachial pressure using brachial at antecubital fossa)
forearm cuff (obtain radial and ulnar pressure from same cuff)
same principles as legs
segmental pressures upper extremities interpretation
compare both brachial to each other
normally they should be within 20mmHg of each other. if greater than 20 diff, proximal disease on arm with lower pressure
look for drops of 20 or more between consecutive verticle levels
20 or more drop means disease between those levels. always compare up. radial to brachial. ulnar to brachial
arterial obstructive disease will — the pressures. disease is — to the lower pressure
decrease; proximal
pupose of the allen test
evaluate patency of the palmar arch
— of the population has an incomplete palmar arch. may be used to confirm usability of radial artery in possible surgical modifications (harvesting or hemodialysis access graft)
50%
allen test technique
apply pressure to radial artery to occlude it
make fist. hand will turn pale as blood id drained from hand
open hand maintaining pressure on artery
standard interpretation of the allen test
color returns to normal
modified interpretation of the allen test
PPG waveforms are maintained throughout compression
which of the following vessels is most likely to have disease with a right brachial pressure of 110 and left brachial pressure of 142
brachiocephalic
what is the purpose of exercise testing
stress the circulation
calculate the ABI of an ankle pressure of 88 mmHg and highest brachial of 132mmHg
0.6
which of the following would be the expected ankle pressure in a normal patient with a brachial pressure of 120mmHg
120
what would be the significance of bilateral ankle pressures of 240 in a patient with a systolic pressure of 110
medial calcinosis