Vocabulary practice flashcards covering therapeutic ultrasound physics and application, phonophoresis protocols, compression garments, intermittent pneumatic compression pumps, and electromagnetic modality physical laws based on PTA Procedures I lecture content.
Ultrasound (US)
Inaudible, acoustic mechanical vibrations of high frequency (>20,000 Hz) that produce both thermal (heating) and non-thermal (cavitation and micromassage) physiological effects when absorbed in body tissues.
Piezoelectric Effect
The conversion of mechanical energy into electrical energy mediated through the deformation of a crystal.
Reverse Piezoelectric Effect
The application of an electrical voltage to a crystal within an ultrasound transducer, causing alternating expansion and contraction at up to 1,000,000 times per second to produce high-frequency mechanical sound waves.
Effective Radiating Area (ERA)
The surface area of the transducer soundhead that transmits acoustic energy from the crystal to the tissue; it is always smaller than the total surface area of the transducer faceplate.
Beam Divergence
The spreading out of the ultrasound beam as it travels away from the transducer, which is greater with smaller transducer surface areas and lower frequencies (1 MHz).
Attenuation
The progressive decrease in ultrasound energy as the sound wave travels through tissues, caused by absorption, reflection, and refraction.
Acoustic Reflection and Refraction
Reflection occurs when ultrasound energy bounces back at tissue interfaces of differing acoustic impedance (such as 20–30% reflecting off bone), while refraction is the bending or deflection of the energy wave based on changes in velocity and wavelength across boundaries.
Coupling Medium Transmission Hierarchy
The relative transmission efficiency of ultrasound energy through various agents: Gel pad (109%), Standard US gel (100%), Glove with degassed water (79%), Glove with tap water (66%), Glove with gel (50%), Degassed water (33%), Tap water (31%), and Condom with gel (23%).
Tissue Absorption Hierarchy for Ultrasound
The specific percentage ranking of energy absorption related to collagen content: Bone (96%), Cartilage (68%), Tendon/Ligament/Joint Capsule (59%), Skin (39%), Blood vessels (32%), Skeletal muscle (24%), Nerve (18%), Fat (13%), and Blood (3%).
1 MHz Frequency
A low-frequency ultrasound setting with greater beam divergence that undergoes less superficial absorption and penetrates deeper tissues between >3 cm and up to 6 cm (e.g., soleus, piriformis, hamstrings).
3 MHz Frequency
A high-frequency ultrasound setting with less beam divergence that is rapidly absorbed in superficial tissues up to 2–3 cm deep (e.g., epicondyles, plantar fascia, patellar tendon), requiring a lower intensity.
Duty Cycle
The ratio of 'on' time to total time during an ultrasound cycle (expressed as a percentage), determining whether heating occurs or if heat dissipates during the rest periods.
Continuous Ultrasound (100% Duty Cycle)
An uninterrupted ultrasound delivery mode used for chronic conditions to produce thermal effects such as increased tissue temperature (1–4∘C), increased collagen extensibility, and reduced joint stiffness.
Pulsed Ultrasound (10% or 20% Duty Cycle)
An interrupted ultrasound delivery mode with rest intervals that yield no measurable heating, utilized during acute stages of healing to stimulate tissue repair via non-thermal mechanisms.
Ultrasound Intensity
The magnitude of energy delivered per unit area, measured in watts per square centimeter (w/cm2), typically ranging from 0.25–3.0 w/cm2 (2.0–3.0 w/cm2 marked in red), which governs energy dose but not depth of penetration.
Cavitation
The formation, expansion, and contraction of gas-filled bubbles within tissue fluids under ultrasound-induced pressure variations; can be stable or unstable (microexplosions causing tissue damage, more prevalent at 1 MHz).
Micromassage
The slight mechanical deformation of cell membranes caused by pressure fluctuations and cavitation from sound waves, which alters cell membrane permeability and accelerates tissue healing.
Ultrasound Application Velocity and Treatment Size
The soundhead must be moved continuously in circular or longitudinal paths at approximately 4 cm/s; treatment area should not exceed 4× the ERA (ideally 1.5–2× the ERA for 8–10 minutes).
Ultrasound Discontinuation Criteria
Ultrasound should be discontinued if there is complete symptom relief, if no positive results are observed within 3–4 treatments, or after reaching a total maximum course of 12–15 treatments.
Phonophoresis
The use of therapeutic ultrasound to drive prescribed transdermal medications (such as dexamethasone, hydrocortisone, or lidocaine) across cell membranes and into target tissues via radiation pressure and acoustic streaming.
Pure Method (Phonophoresis)
A phonophoresis technique in which the prescribed medication cream (e.g., hydrocortisone) serves as the sole transmission couplant between the applicator and the skin.
Smear Method (Phonophoresis)
A phonophoresis application technique where the medication is first spread and rubbed directly onto the patient's skin, followed by standard ultrasound transmission gel applied over top.
Centrifuged Method (Phonophoresis)
The most common phonophoresis technique, wherein the pharmacy pre-mixes the prescribed medication cream with ultrasound transmission gel to form a single uniform coupling medium.
Phonophoresis Treatment Parameters
Ultrasound delivery with intensity kept low at <0.5 w/cm2 (due to enhanced penetration with medications), pulsed mode (20% for acute, 50% for subacute), and duration between 5–10 minutes.
Graduated Compression
An external elastic force that provides highest pressure at the distal extremity (ankle) and progressively lower pressure proximally toward the calf and thigh to promote venous return.
TED Hose Pressure Gradient
Anti-embolism stockings designed for non-ambulatory hospital patients with a graduated pressure profile of 18 mmHg at the ankle, 14 mmHg at the popliteal space, 10 mmHg at the lower thigh, and 8 mmHg at the upper thigh.
Varicose Veins vs. Spider Veins
Varicose veins are enlarged, twisted, and stretched veins caused by valve damage and increased retrograde pressure; spider veins are small, superficial, knotted, bluish vessels visible on the skin surface.
Compression Garment Class: Mild Vascular (18–25 mmHg)
The lowest durable medical equipment pressure rating, prescribed for mild vascular conditions such as mild dependent edema or orthostatic hypotension.
Compression Garment Class: Moderate Vascular (25/30–40 mmHg)
A therapeutic compression level indicated for moderate clinical manifestations, including moderate lymphedema, varicose veins, and venous stasis ulcers.
Compression Garment Class: Severe Vascular (40–50 mmHg)
A high-pressure compression garment class indicated for severe conditions such as advanced intractable lymphedema or severe refractory orthostatic hypotension.
Circumferential Compression Measurement Protocol
Limb measurements taken early in the morning when swelling is lowest, with the limb elevated; circumferential points are measured using manufacturer paper tape every 1 inch or 1.5 inches from distal to proximal.
Intermittent Vasopneumatic Compression Device
A pneumatic unit connected to a single- or multi-compartment inflatable sleeve to deliver sequential distal-to-proximal external pressure for treating non-orthopedic chronic and acute edema or venous insufficiency.
Vasopneumatic Compression Pressure Parameters
Inflation pressure must never exceed the patient's diastolic blood pressure; typical safe ranges are 40–60 mmHg for upper extremities and 80–90 mmHg for lower extremities.
Vasopneumatic Compression Duty Cycle
A preset 3:1 ratio of inflation to deflation time, consisting of 45 seconds on (inflation) followed by 15 seconds off (deflation).
Transudate vs. Exudate Edema
Transudate edema is clear, watery, low-protein swelling containing electrolytes (mild edema); Exudate edema is milky, high in plasma proteins, pus-containing, mildly odorous, and prone to infection (extreme edema).
Lymphatic vs. Venous Edema
Lymphatic edema is stagnant, protein-rich tissue fluid caused by impaired lymphatic drainage (prone to infection); venous edema results from increased capillary filtration pressure due to venous obstruction or incompetent valves.
Rate of Edema Scale
A clinical grading scale scored from 0 to +4, where 0 indicates no edema, +1 indicates barely noticeable swelling, and +4 indicates extreme swelling where the body part is 1.5× its normal size.
Electromagnetic Radiation (ER)
Energy composed of perpendicular, oscillating electric and magnetic fields that travel together through space in a straight line at the speed of light until interacting with biological tissue.
Law of Grotthus-Draper
A physical law stating that only electromagnetic radiations that are actually absorbed by biological tissues can produce physical and secondary therapeutic effects.
Arndt-Schultz Principle
A biological principle stating that therapeutic effects occur only if a sufficient threshold of energy is absorbed: insufficient energy produces no response, whereas excessive energy can cause tissue damage or inhibit repair.
Inverse Square Law
A physical law establishing that the intensity of radiation reaching a target surface is inversely proportional to the square of the distance from the source: Intensity∝Distance21.
Cosine Law
A principle stating that radiant energy absorption is maximal when the energy beam strikes perpendicular (90∘ angle) to the target surface; deviation away from 90∘ causes reflection and proportional loss of absorbed energy.
Bunsen-Roscoe Law of Reciprocity
A photochemical law expressing total delivered energy (dosage) as the product of radiation intensity (power) and exposure duration: E=I×T.