Ultrasound, Phonophoresis, Compression, and Electromagnetic Modalities

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/42

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering therapeutic ultrasound physics and application, phonophoresis protocols, compression garments, intermittent pneumatic compression pumps, and electromagnetic modality physical laws based on PTA Procedures I lecture content.

43 Terms

1
New cards

Ultrasound (US)

Inaudible, acoustic mechanical vibrations of high frequency (>20,000 Hz>20{,}000\text{ Hz}) that produce both thermal (heating) and non-thermal (cavitation and micromassage) physiological effects when absorbed in body tissues.

2
New cards

Piezoelectric Effect

The conversion of mechanical energy into electrical energy mediated through the deformation of a crystal.

3
New cards

Reverse Piezoelectric Effect

The application of an electrical voltage to a crystal within an ultrasound transducer, causing alternating expansion and contraction at up to 1,000,000 times per second1{,}000{,}000\text{ times per second} to produce high-frequency mechanical sound waves.

4
New cards

Effective Radiating Area (ERA)

The surface area of the transducer soundhead that transmits acoustic energy from the crystal to the tissue; it is always smaller than the total surface area of the transducer faceplate.

5
New cards

Beam Divergence

The spreading out of the ultrasound beam as it travels away from the transducer, which is greater with smaller transducer surface areas and lower frequencies (1 MHz1\text{ MHz}).

6
New cards

Attenuation

The progressive decrease in ultrasound energy as the sound wave travels through tissues, caused by absorption, reflection, and refraction.

7
New cards

Acoustic Reflection and Refraction

Reflection occurs when ultrasound energy bounces back at tissue interfaces of differing acoustic impedance (such as 20–30%20\text{--}30\% reflecting off bone), while refraction is the bending or deflection of the energy wave based on changes in velocity and wavelength across boundaries.

8
New cards

Coupling Medium Transmission Hierarchy

The relative transmission efficiency of ultrasound energy through various agents: Gel pad (109%109\%), Standard US gel (100%100\%), Glove with degassed water (79%79\%), Glove with tap water (66%66\%), Glove with gel (50%50\%), Degassed water (33%33\%), Tap water (31%31\%), and Condom with gel (23%23\%).

9
New cards

Tissue Absorption Hierarchy for Ultrasound

The specific percentage ranking of energy absorption related to collagen content: Bone (96%96\%), Cartilage (68%68\%), Tendon/Ligament/Joint Capsule (59%59\%), Skin (39%39\%), Blood vessels (32%32\%), Skeletal muscle (24%24\%), Nerve (18%18\%), Fat (13%13\%), and Blood (3%3\%).

10
New cards

1 MHz1\text{ MHz} Frequency

A low-frequency ultrasound setting with greater beam divergence that undergoes less superficial absorption and penetrates deeper tissues between >3 cm>3\text{ cm} and up to 6 cm6\text{ cm} (e.g., soleus, piriformis, hamstrings).

11
New cards

3 MHz3\text{ MHz} Frequency

A high-frequency ultrasound setting with less beam divergence that is rapidly absorbed in superficial tissues up to 2–3 cm2\text{--}3\text{ cm} deep (e.g., epicondyles, plantar fascia, patellar tendon), requiring a lower intensity.

12
New cards

Duty Cycle

The ratio of 'on' time to total time during an ultrasound cycle (expressed as a percentage), determining whether heating occurs or if heat dissipates during the rest periods.

13
New cards

Continuous Ultrasound (100%100\% Duty Cycle)

An uninterrupted ultrasound delivery mode used for chronic conditions to produce thermal effects such as increased tissue temperature (1–4∘C1\text{--}4^\circ\text{C}), increased collagen extensibility, and reduced joint stiffness.

14
New cards

Pulsed Ultrasound (10%10\% or 20%20\% Duty Cycle)

An interrupted ultrasound delivery mode with rest intervals that yield no measurable heating, utilized during acute stages of healing to stimulate tissue repair via non-thermal mechanisms.

15
New cards

Ultrasound Intensity

The magnitude of energy delivered per unit area, measured in watts per square centimeter (w/cm2\text{w/cm}^2), typically ranging from 0.25–3.0 w/cm20.25\text{--}3.0\text{ w/cm}^2 (2.0–3.0 w/cm22.0\text{--}3.0\text{ w/cm}^2 marked in red), which governs energy dose but not depth of penetration.

16
New cards

Cavitation

The formation, expansion, and contraction of gas-filled bubbles within tissue fluids under ultrasound-induced pressure variations; can be stable or unstable (microexplosions causing tissue damage, more prevalent at 1 MHz1\text{ MHz}).

17
New cards

Micromassage

The slight mechanical deformation of cell membranes caused by pressure fluctuations and cavitation from sound waves, which alters cell membrane permeability and accelerates tissue healing.

18
New cards

Ultrasound Application Velocity and Treatment Size

The soundhead must be moved continuously in circular or longitudinal paths at approximately 4 cm/s4\text{ cm/s}; treatment area should not exceed 4×4\times the ERA (ideally 1.5–2×1.5\text{--}2\times the ERA for 8–10 minutes8\text{--}10\text{ minutes}).

19
New cards

Ultrasound Discontinuation Criteria

Ultrasound should be discontinued if there is complete symptom relief, if no positive results are observed within 3–43\text{--}4 treatments, or after reaching a total maximum course of 12–1512\text{--}15 treatments.

20
New cards

Phonophoresis

The use of therapeutic ultrasound to drive prescribed transdermal medications (such as dexamethasone, hydrocortisone, or lidocaine) across cell membranes and into target tissues via radiation pressure and acoustic streaming.

21
New cards

Pure Method (Phonophoresis)

A phonophoresis technique in which the prescribed medication cream (e.g., hydrocortisone) serves as the sole transmission couplant between the applicator and the skin.

22
New cards

Smear Method (Phonophoresis)

A phonophoresis application technique where the medication is first spread and rubbed directly onto the patient's skin, followed by standard ultrasound transmission gel applied over top.

23
New cards

Centrifuged Method (Phonophoresis)

The most common phonophoresis technique, wherein the pharmacy pre-mixes the prescribed medication cream with ultrasound transmission gel to form a single uniform coupling medium.

24
New cards

Phonophoresis Treatment Parameters

Ultrasound delivery with intensity kept low at <0.5 w/cm2<0.5\text{ w/cm}^2 (due to enhanced penetration with medications), pulsed mode (20%20\% for acute, 50%50\% for subacute), and duration between 5–10 minutes5\text{--}10\text{ minutes}.

25
New cards

Graduated Compression

An external elastic force that provides highest pressure at the distal extremity (ankle) and progressively lower pressure proximally toward the calf and thigh to promote venous return.

26
New cards

TED Hose Pressure Gradient

Anti-embolism stockings designed for non-ambulatory hospital patients with a graduated pressure profile of 18 mmHg18\text{ mmHg} at the ankle, 14 mmHg14\text{ mmHg} at the popliteal space, 10 mmHg10\text{ mmHg} at the lower thigh, and 8 mmHg8\text{ mmHg} at the upper thigh.

27
New cards

Varicose Veins vs. Spider Veins

Varicose veins are enlarged, twisted, and stretched veins caused by valve damage and increased retrograde pressure; spider veins are small, superficial, knotted, bluish vessels visible on the skin surface.

28
New cards

Compression Garment Class: Mild Vascular (18–25 mmHg18\text{--}25\text{ mmHg})

The lowest durable medical equipment pressure rating, prescribed for mild vascular conditions such as mild dependent edema or orthostatic hypotension.

29
New cards

Compression Garment Class: Moderate Vascular (25/30–40 mmHg25/30\text{--}40\text{ mmHg})

A therapeutic compression level indicated for moderate clinical manifestations, including moderate lymphedema, varicose veins, and venous stasis ulcers.

30
New cards

Compression Garment Class: Severe Vascular (40–50 mmHg40\text{--}50\text{ mmHg})

A high-pressure compression garment class indicated for severe conditions such as advanced intractable lymphedema or severe refractory orthostatic hypotension.

31
New cards

Circumferential Compression Measurement Protocol

Limb measurements taken early in the morning when swelling is lowest, with the limb elevated; circumferential points are measured using manufacturer paper tape every 1 inch1\text{ inch} or 1.5 inches1.5\text{ inches} from distal to proximal.

32
New cards

Intermittent Vasopneumatic Compression Device

A pneumatic unit connected to a single- or multi-compartment inflatable sleeve to deliver sequential distal-to-proximal external pressure for treating non-orthopedic chronic and acute edema or venous insufficiency.

33
New cards

Vasopneumatic Compression Pressure Parameters

Inflation pressure must never exceed the patient's diastolic blood pressure; typical safe ranges are 40–60 mmHg40\text{--}60\text{ mmHg} for upper extremities and 80–90 mmHg80\text{--}90\text{ mmHg} for lower extremities.

34
New cards

Vasopneumatic Compression Duty Cycle

A preset 3:13:1 ratio of inflation to deflation time, consisting of 45 seconds45\text{ seconds} on (inflation) followed by 15 seconds15\text{ seconds} off (deflation).

35
New cards

Transudate vs. Exudate Edema

Transudate edema is clear, watery, low-protein swelling containing electrolytes (mild edema); Exudate edema is milky, high in plasma proteins, pus-containing, mildly odorous, and prone to infection (extreme edema).

36
New cards

Lymphatic vs. Venous Edema

Lymphatic edema is stagnant, protein-rich tissue fluid caused by impaired lymphatic drainage (prone to infection); venous edema results from increased capillary filtration pressure due to venous obstruction or incompetent valves.

37
New cards

Rate of Edema Scale

A clinical grading scale scored from 00 to +4+4, where 00 indicates no edema, +1+1 indicates barely noticeable swelling, and +4+4 indicates extreme swelling where the body part is 1.5×1.5\times its normal size.

38
New cards

Electromagnetic Radiation (ER)

Energy composed of perpendicular, oscillating electric and magnetic fields that travel together through space in a straight line at the speed of light until interacting with biological tissue.

39
New cards

Law of Grotthus-Draper

A physical law stating that only electromagnetic radiations that are actually absorbed by biological tissues can produce physical and secondary therapeutic effects.

40
New cards

Arndt-Schultz Principle

A biological principle stating that therapeutic effects occur only if a sufficient threshold of energy is absorbed: insufficient energy produces no response, whereas excessive energy can cause tissue damage or inhibit repair.

41
New cards

Inverse Square Law

A physical law establishing that the intensity of radiation reaching a target surface is inversely proportional to the square of the distance from the source: Intensity∝1Distance2\text{Intensity} \propto \frac{1}{\text{Distance}^2}.

42
New cards

Cosine Law

A principle stating that radiant energy absorption is maximal when the energy beam strikes perpendicular (90∘90^\circ angle) to the target surface; deviation away from 90∘90^\circ causes reflection and proportional loss of absorbed energy.

43
New cards

Bunsen-Roscoe Law of Reciprocity