plumbing help practice ip questions

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/77

encourage image

There's no tags or description

Looks like no tags are added yet.

78 Terms

1
New cards

You are required to use a 20 foot ladder placed up against a building that is 40' high. At what horizontal distance from the base of the building must the ladder be?

5' 4:1 rule

2
New cards

Confined spaces are hazardous environments because they usually have:

restricted access and egress

3
New cards

Scaffolding erected_______ feet above the ground must have guard rails.

10'

4
New cards

Class "A" fire extinguishers are used on and contain

Combustible materials, Water

5
New cards

When using a Hilti powder actuated fastening tool, the device fails to fire when the trigger is pulled. The first thing you should do is?

keep the tool in position and wait 30 seconds

6
New cards

How many 2" pipes does it take to equal the volume capacity of a 6" pipe?

9

7
New cards

When using oxy-fuel cutting and welding equipment, a flashback arrestor protects the operator from?

flame traveling into the hoses

8
New cards

Horizontally run ô" type M copper pipe must be supported every:

2.5 meters

9
New cards

Water that is determined to have a PH of 5.5 would be considered:

mildly acidic

10
New cards

Copper tube permitted for underground water distribution.

type k soft

11
New cards

Which is not an approved method for joining cast iron waste pipe:

welded joint

12
New cards

Dielectric unions are used to

prevent corrosion

13
New cards

When installing glass piping; if one end needs to be field cut, the ends should be joined:

bead to plain

14
New cards

Bell and spigot cast iron is installed with the:

bell upstream

15
New cards

What force would be exerted on the gate of a closed 6" gate valve if the water pressure acting on it measured 46 Psig.

1300 - area of the gate x psi

16
New cards

Asbestos cement pipe installed below a 60 mm thick concrete floor must be at least how deep?

600mm

17
New cards

What is the maximum practical lift of a shallow well jet pump?

25'

18
New cards

A backwater valve may be installed in a building drain provided that it is

normally open

19
New cards

The discharge from a sump pump shall have the following fittings installed in order, in the direction of flow:

union, check valve, shut-off valve

20
New cards

When a well pump turns on as soon as a faucet is used the most likely problem is:

water logged pressure tank

21
New cards

A 4" cast iron pipe with 1" insulation is to pass through a wall. How large a diameter hole is required to be cut?

4" pipe + pipe wall thickness ½" + 2" insulation = 6.5"

22
New cards

A gear pump is a positive displacement pump and must be installed with a:

pressure relief valve

23
New cards

What type of trap is not permitted in a drainage system:

bell trap

24
New cards

Where is the jet located in a deep well?

above the foot valve

25
New cards

How would you increase the length of flush on a flushometer?

turn regulating screw clockwise

26
New cards

Six equally spaced lav's are to be installed along a wall that is 530 cm long and will be vented with dual vents. Determine the center to center distance between vents if the fixtures are each 51 cm wide.

166cm

27
New cards

A drainage pipe suspended from a ceiling inside a building at it most upstream end is 7.5" from the ceiling to the center of the pipe. What will the measurement be from the ceiling to the center of the pipe if it travels 26 feet horizontally, has an 8 foot horizontal offset then continues another 37 feet.

25.25"

28
New cards

What is the minimum length of a trap arm?

2 pipe diameters

29
New cards

A branch with 34 fixture units discharges into a sewage sump. What is the minimum size vent required for the sump?

3"

30
New cards

What is the maximum vertical fall of a water closet trap arm?

1m

31
New cards

A building's roof measuring 90m by 50m would require how many flow controlled roof drains?

6

32
New cards

A flat roof measuring 20m by 26m with a horizontal wall on one side extended up 6m by 20m. Size the circular rain water leader if the local 15 minute rain fall intensity is 24mm.

6"

33
New cards

A laboratory sink that receives bio-hazardous waste must be installed with a:

cleanout above the flood level rim

34
New cards

The absorption rate of a septic field is determined by:

percolation test

35
New cards

Medical gas piping is most often joined by

compression joints

36
New cards

A circuit vented branch with a horizontal offset that uses two 45º fittings will require a:

additional circuit vent

37
New cards

Determine the amount of expansion that will occur when a 15m ABS pipe has a temperature change of 40ºC

54mm

38
New cards

Which backflow preventer is not a testable device?

DCAP

39
New cards

. Find the length of pipe "D" if (A=50mm, R=150mm, C=1400mm, E=30mm)

1087.2mm

40
New cards

The image above shows a 45º rolling offset. Find the length of pipe "C".

46.58"

41
New cards

A properly cut thread on black iron pipe should allow how many hand turns with a fitting?

3 1/2

42
New cards

A well with a water tight casing requires a minimum standoff distance from a septic system of:

15m

43
New cards

An air conditioner that discharges 0.05 L/s of condensate into a floor drain, would equate to how many fixture units?

2

44
New cards

An interceptor may act as a trap for a fixture provided that:

it has a 38mm water seal

45
New cards

. Underground piping installed in a dug trench should be covered with appropriate backfill to a height of:

300mm

46
New cards

Which is not a hot water heating piping system:

one pipe gravity return

47
New cards

The ideal location for a circulator pump installed in a hot water heating system is:

on the supply after the expansion tank

48
New cards

A pipe that connects at its downstream end to two or more vent pipes and at its upper end to a vent stack or stack vent is a:

branch vent

49
New cards

A horizontal cylindrical tank measuring 60cm in diameter and 150cm in length is partially filled with water to a height of 48cm. Find the volume of water

364L

50
New cards

When determining the location to install a condensing boiler what must be considered?

near a floor drain

51
New cards

The discharge piping from a service water heater's temperature and pressure relief valve must discharge within _______ of a floor drain or suitable area.

300mm

52
New cards

. Length is not a consideration when sizing this vent:

relief vent

53
New cards

A cross fitting may not be used in a DWV system except to connect:

four vents

54
New cards

A ½" extracted tee may be formed from:

3/4" Type K

55
New cards

If four shower heads are installed along a wall, what would the minimum measurement be between the two outermost heads?

2.25m

56
New cards

The minimum size for vents serving an oil interceptor are:

1 1/4"

57
New cards

A four wire zone valve is wired to

thermostat, transformer, end switches

58
New cards

Which of the following fixtures may not be indirectly connected to a drainage system:

commercial dishwasher

59
New cards

The minimum size for mobile home service connections are

4" sewer, 3/4" water

60
New cards

A pressure reducing valve must be installed if the water service pressure is above

80 psi (550 Kpa)

61
New cards

A twin tank water softener will house the brine in one tank and the other tank will house the:

zeolite

62
New cards

Where should you locate a fin tube radiator within a room?

under a window

63
New cards

Water that has a dissolved mineral content of >181 mg/L would be deemed"

very hard

64
New cards

A private water supplied cistern is fitted with a ô" make-up water pipe supplied by a municipal system. What size air gap would be required:

1 1/2"

65
New cards

If the center to center measurement of pipe "A" is 8' 6"(2590mm) dimension "B" would be:

12' 1/4" (3662mm)

66
New cards

. A ô" cold water branch with a developed length of 6.5m could supply how many public use showers?

4

67
New cards

The abbreviation NPS refers to:

pipe size

68
New cards

What is the maximum horizontal offset permitted in a 3" soil or waste stack that is serving as a wet vent?

2.5m

69
New cards

Which manufacturing method produces the strongest pipe:

extruded

70
New cards

A toilet seat used in a public washroom must be:

elongated open front type

71
New cards

the base of every soil or waste stack must have

clean out and expansion joint

72
New cards

the minimum size of a wet vent serving a water closet is

2"

73
New cards

a section of ____________ branch may be circuit vented

horizontal

74
New cards

the minimum size of a fresh air inlet for a building trap is

4"

75
New cards

the minimum size of a future vent in a basement is

1 1/2"

76
New cards

the minimum diameter of a trap on a floor drain that does not require venting is

3"

77
New cards

a yoke vent is connected to a 2" branch and a 3" vent stack, the yoke vent is sized at

1 1/2"

78
New cards

an offset relief vent is being utilized within a buildings DWV system. The base of the stack is 6" in diameter and the stack vent is 3" in size. The offset relief vent will be sized at

2"