practice exam 1

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/150

encourage image

There's no tags or description

Looks like no tags are added yet.

151 Terms

1
New cards

lower motor neurons primarily exit the spinal cord through

ventral nerve roots

2
New cards

upper extremity SSEPs transmit through which cord tract

fasciculus cuneatus

3
New cards

the C8 nerve roots exits the spinal cord

above the T1 vertebrae

4
New cards

what is the initial event that occurs when the action potential threshold of a neuron is reached

voltage gated sodium channels open

5
New cards

sodium-potassium pump

pumps K+ into the cell and Na+ out of the cell

6
New cards

tcmeps transmit primarily through which spinal cord tract

lateral corticospinal tract

7
New cards

what separates the motor cortex from the sensory cortex

central sulcus

8
New cards

the anterior communicating artery connects which arteries

left and right anterior cerebral arteries

9
New cards

which of the following drugs has an appreciable effect on peripheral nerve APs

none of these

10
New cards

which of the following is a barbiturate

methohexital

11
New cards

desflurane has a more rapid onset and recovery than isoflurane because

desflurane has a lower blood solubility than isoflurane

12
New cards

which of the following is consistent with increasing depth of anesthesia

bilateral reduction of cortical SSEPs only

13
New cards

which of the following can increase SSEP amplitudes

etomidate

14
New cards

if a sound intensity is increased from 20dB to 40dB then the sound pressure has increased by a factor of

10

15
New cards

in ABR stimulation, the stimulus type which causes a negative pressure resulting in a slightly earlier latency is

rarefaction

16
New cards

ABR condensation clicks from the transducer causes

movement of the tympanic membrane toward the cochlea

17
New cards

an ABR has a normal wave I and then delayed wave I-V on one side. what type of surgery is this most consistent with?

CPA tumor

18
New cards

where is the ABR wave V generated?

midbrain

19
New cards

when can the ABR no longer be successfully performed? after resection of

acoustic nerve

20
New cards

CNS depressants cause

minimal effects on ABRs

21
New cards

which of the following is most consistent with a discrete lesion of the medial geniculate body

no change in waves I-V

22
New cards

what montage will help you discern wave IV and V in an ABR?

Cz-contra ear

23
New cards

if the eighth nerve were transected, you may get

absence of waves III-V

24
New cards

an optimal repetition rate for ABRs is

31 Hz

25
New cards

what is the acceptable sweep for ABRs?

10-15mS

26
New cards

the most appropriate ABR interstimulus interval is

20mS

27
New cards

you would expect a loss of ABRs in which surgery

pontine glioma

28
New cards

the appropriate analysis time for ABRs is

15mS

29
New cards

after discharges occur after what

direct cortical stimulation

30
New cards

when no phase reversal is present in an anterior-posterior cortical grid recording

the maximum amplitude response is closest to the central sulcus

31
New cards

cranial nerve IV can be monitored using electrodes inserted into the

superior oblique

32
New cards

what type of electrode is recommended for monitoring the facial nerve

hook-wire

33
New cards

the integrity of the facial nerve in acoustic neuroma surgery is determined by

proximal CMAP

34
New cards

what cranial nerves should be ideally monitored for CP angle tumors

VII & VIII

35
New cards

muscles for monitoring facial nerve

orbicular oris/oculi

36
New cards

the facial nerve CMAP has a latency of approximately

7mS

37
New cards

the trigeminal nerve EMG response has a latency of approximately

3-5mS

38
New cards

cranial nerve XII can be monitored using electrodes inserted into the

tongue

39
New cards

what might be monitored for a jugular bulb tumor surgery

CNVII-XII

40
New cards

cranial nerve X can be monitored using electrodes inserted into the

vocalis muscle

41
New cards

of the following, the most appropriate filter, timebase and sensitivity for monitoring of cortical ischemia during a carotid surgery are

0.3-70Hz, 15mm/S, 3uV/mm

42
New cards

most strokes associated with carotid endarterectomy occur

after the cross clamping is released

43
New cards

eeg will most likely disappear at what body temperature

16 degrees C

44
New cards

what is the maximum time in which to expect EEG changes following cross clamping of the carotid

2 minutes

45
New cards

cardiac activity appears on the CSA/DSA display as

delta activity

46
New cards

what EEG changes would you expect after intracarotid sodium amytal

ipsilateral decrease in high frequency

47
New cards

according to the nurses guidelines how far do you need to be from the sterile field

18 inches

48
New cards

what is the maximum allowable chassis leakage current

0.1mA

49
New cards

what is the maximum allowable leakage current from the isolated amplifier inputs through the patient leads

10 uA

50
New cards

platinum electrodes are used to record epidural potentials because

other elements cause neurotoxicity when current is passed through them

51
New cards

impedance is

opposition to alternating current flow

52
New cards

the gain of a differential amplifier is defined as

output voltage divided by input voltage

53
New cards

the positive input of a differential amplifier is also called the

non-inverting input

54
New cards

the minimum required common mode rejection ratio of a differential amplifier is

10000:1

55
New cards

the input impedance of a differential amplifier should be

at least 100 megaohms

56
New cards

lowering the SSEP hicut filter from 500Hz to 200Hz may cuase the cortical peaks to

appear longer in latency

57
New cards

what is the required horizontal resolution of an evoked potential system

20uS per data point or less

58
New cards

the vertical resolution of an evoked potential system depends primarily on the

number of bits in the A/D converter

59
New cards

Nyquist frequency

one half the sampling rate of the evoked potential system

60
New cards

if the bin width of your system is 20uS, then then highest frequency signal that can be resolved is

25KHz

61
New cards

why do we use electrodes with the same metals

to prevent electrode polarization

62
New cards

the stimulation rate is determined by the

analysis time

63
New cards

brown-sequard

spinal cord

64
New cards

meniere’s disease

inner ear disturbance

65
New cards

a shocking sensation that occurs throughout the body during neck flexion is called

L’Hermittes sign

66
New cards

brown-sequard syndrome

hemi-spinal cord lesion

67
New cards

which of the following is most likely associated with abnormal posterior tibial SSEPs

Romberg sign

68
New cards

Tinel’s sign

peripheral nerve

69
New cards

kyphosis

concave curvature of the spine

70
New cards

which of the following will result in significantly elevated SSEP latencies

Charcot-marie tooth disease

71
New cards

Cortel-Dubousset instrumentation involves which of the following:

derotation

72
New cards

harrington rod instrumentation uses

hooks and a rod

73
New cards

for peroneal nerve stimulation, the ground should be placed

thigh

74
New cards

SSEP recordings are thought to be generated by which of the following sensory tracts

posterior columns and medial lemnisci

75
New cards

a loss of SSEP response would most likely occur ____ to the surgical site

rostral

76
New cards

why are SSEP and MEP used simultaneously?

spinal cord damage can occur in only one tract causing loss of MEP but not SSEP

77
New cards

your record a spinal potential to

establish an AP

78
New cards

the central conduction time for median nerve SSEP is

P14-N20

79
New cards

which of the following is true of transcranial magnetic stimulation

responses are sensitive to positioning of the magnetic coils

80
New cards

a 60Hz artifact would most likely be caused by

infusion pump

81
New cards

What will be the frequency of a signal if in a 30 mS sweep the interval between each cycle of the signal is 0.03 mS?

33Khz

82
New cards

upper motor neurons

brainstem

83
New cards

ipsilateral cranial nerve deficits combined with contralateral motor deficits indicate what site of lesion

brainstem

84
New cards

a nerve cell membrane can depolarize when

the summation of individual action potentials exceeds the membrane threshold

85
New cards

the innermost connective tissue membrane covering the brain

pia

86
New cards

which of the following can cause generalized seizure activity

enflurane

87
New cards

which of the following is least affected by the patient’s state of cognition

BAEP

88
New cards

which of the following will have the least effect on median nerve responses

atracurium

89
New cards

at the stage of surgical anesthesia, propofol affects the ABR by

increasing the latencies of waves I, III and V without changing their amplitudes

90
New cards

when used as an induction agent, which of the following drugs will have the least effect on the SSEP?

propofol

91
New cards

if the VIIIth were transected, you would get

loss of waves III-V

92
New cards

what is the minimum acceptable sweep for ABRs

10mS

93
New cards

of the following, the peak equivalent SPL of a click should be calibrated at

1000Hz

94
New cards

the most diagnostic part of the ABR is

I-V interpeak latency

95
New cards

which of the following are acceptable filter settings for recording ABRs

10-2500Hz

96
New cards

which of the following would most likely result in an increased I-III interval

vestibular schwannoma

97
New cards

if a sound intensity is decreased from 80dB to 60dB then the sound pressure has been decreased by a factor of

10

98
New cards

the use of ER insert earphones results in

separating wave I from the stimulus artifact

99
New cards

what montage will help you discern waves IV and V in an ABR

Cz-contra ear

100
New cards

the sound stimulus intensity at the tympanic membrane depends on the

acoustic coupling between the sound stimulus generator and the ear