1/150
Looks like no tags are added yet.
lower motor neurons primarily exit the spinal cord through
ventral nerve roots
upper extremity SSEPs transmit through which cord tract
fasciculus cuneatus
the C8 nerve roots exits the spinal cord
above the T1 vertebrae
what is the initial event that occurs when the action potential threshold of a neuron is reached
voltage gated sodium channels open
sodium-potassium pump
pumps K+ into the cell and Na+ out of the cell
tcmeps transmit primarily through which spinal cord tract
lateral corticospinal tract
what separates the motor cortex from the sensory cortex
central sulcus
the anterior communicating artery connects which arteries
left and right anterior cerebral arteries
which of the following drugs has an appreciable effect on peripheral nerve APs
none of these
which of the following is a barbiturate
methohexital
desflurane has a more rapid onset and recovery than isoflurane because
desflurane has a lower blood solubility than isoflurane
which of the following is consistent with increasing depth of anesthesia
bilateral reduction of cortical SSEPs only
which of the following can increase SSEP amplitudes
etomidate
if a sound intensity is increased from 20dB to 40dB then the sound pressure has increased by a factor of
10
in ABR stimulation, the stimulus type which causes a negative pressure resulting in a slightly earlier latency is
rarefaction
ABR condensation clicks from the transducer causes
movement of the tympanic membrane toward the cochlea
an ABR has a normal wave I and then delayed wave I-V on one side. what type of surgery is this most consistent with?
CPA tumor
where is the ABR wave V generated?
midbrain
when can the ABR no longer be successfully performed? after resection of
acoustic nerve
CNS depressants cause
minimal effects on ABRs
which of the following is most consistent with a discrete lesion of the medial geniculate body
no change in waves I-V
what montage will help you discern wave IV and V in an ABR?
Cz-contra ear
if the eighth nerve were transected, you may get
absence of waves III-V
an optimal repetition rate for ABRs is
31 Hz
what is the acceptable sweep for ABRs?
10-15mS
the most appropriate ABR interstimulus interval is
20mS
you would expect a loss of ABRs in which surgery
pontine glioma
the appropriate analysis time for ABRs is
15mS
after discharges occur after what
direct cortical stimulation
when no phase reversal is present in an anterior-posterior cortical grid recording
the maximum amplitude response is closest to the central sulcus
cranial nerve IV can be monitored using electrodes inserted into the
superior oblique
what type of electrode is recommended for monitoring the facial nerve
hook-wire
the integrity of the facial nerve in acoustic neuroma surgery is determined by
proximal CMAP
what cranial nerves should be ideally monitored for CP angle tumors
VII & VIII
muscles for monitoring facial nerve
orbicular oris/oculi
the facial nerve CMAP has a latency of approximately
7mS
the trigeminal nerve EMG response has a latency of approximately
3-5mS
cranial nerve XII can be monitored using electrodes inserted into the
tongue
what might be monitored for a jugular bulb tumor surgery
CNVII-XII
cranial nerve X can be monitored using electrodes inserted into the
vocalis muscle
of the following, the most appropriate filter, timebase and sensitivity for monitoring of cortical ischemia during a carotid surgery are
0.3-70Hz, 15mm/S, 3uV/mm
most strokes associated with carotid endarterectomy occur
after the cross clamping is released
eeg will most likely disappear at what body temperature
16 degrees C
what is the maximum time in which to expect EEG changes following cross clamping of the carotid
2 minutes
cardiac activity appears on the CSA/DSA display as
delta activity
what EEG changes would you expect after intracarotid sodium amytal
ipsilateral decrease in high frequency
according to the nurses guidelines how far do you need to be from the sterile field
18 inches
what is the maximum allowable chassis leakage current
0.1mA
what is the maximum allowable leakage current from the isolated amplifier inputs through the patient leads
10 uA
platinum electrodes are used to record epidural potentials because
other elements cause neurotoxicity when current is passed through them
impedance is
opposition to alternating current flow
the gain of a differential amplifier is defined as
output voltage divided by input voltage
the positive input of a differential amplifier is also called the
non-inverting input
the minimum required common mode rejection ratio of a differential amplifier is
10000:1
the input impedance of a differential amplifier should be
at least 100 megaohms
lowering the SSEP hicut filter from 500Hz to 200Hz may cuase the cortical peaks to
appear longer in latency
what is the required horizontal resolution of an evoked potential system
20uS per data point or less
the vertical resolution of an evoked potential system depends primarily on the
number of bits in the A/D converter
Nyquist frequency
one half the sampling rate of the evoked potential system
if the bin width of your system is 20uS, then then highest frequency signal that can be resolved is
25KHz
why do we use electrodes with the same metals
to prevent electrode polarization
the stimulation rate is determined by the
analysis time
brown-sequard
spinal cord
meniere’s disease
inner ear disturbance
a shocking sensation that occurs throughout the body during neck flexion is called
L’Hermittes sign
brown-sequard syndrome
hemi-spinal cord lesion
which of the following is most likely associated with abnormal posterior tibial SSEPs
Romberg sign
Tinel’s sign
peripheral nerve
kyphosis
concave curvature of the spine
which of the following will result in significantly elevated SSEP latencies
Charcot-marie tooth disease
Cortel-Dubousset instrumentation involves which of the following:
derotation
harrington rod instrumentation uses
hooks and a rod
for peroneal nerve stimulation, the ground should be placed
thigh
SSEP recordings are thought to be generated by which of the following sensory tracts
posterior columns and medial lemnisci
a loss of SSEP response would most likely occur ____ to the surgical site
rostral
why are SSEP and MEP used simultaneously?
spinal cord damage can occur in only one tract causing loss of MEP but not SSEP
your record a spinal potential to
establish an AP
the central conduction time for median nerve SSEP is
P14-N20
which of the following is true of transcranial magnetic stimulation
responses are sensitive to positioning of the magnetic coils
a 60Hz artifact would most likely be caused by
infusion pump
What will be the frequency of a signal if in a 30 mS sweep the interval between each cycle of the signal is 0.03 mS?
33Khz
upper motor neurons
brainstem
ipsilateral cranial nerve deficits combined with contralateral motor deficits indicate what site of lesion
brainstem
a nerve cell membrane can depolarize when
the summation of individual action potentials exceeds the membrane threshold
the innermost connective tissue membrane covering the brain
pia
which of the following can cause generalized seizure activity
enflurane
which of the following is least affected by the patient’s state of cognition
BAEP
which of the following will have the least effect on median nerve responses
atracurium
at the stage of surgical anesthesia, propofol affects the ABR by
increasing the latencies of waves I, III and V without changing their amplitudes
when used as an induction agent, which of the following drugs will have the least effect on the SSEP?
propofol
if the VIIIth were transected, you would get
loss of waves III-V
what is the minimum acceptable sweep for ABRs
10mS
of the following, the peak equivalent SPL of a click should be calibrated at
1000Hz
the most diagnostic part of the ABR is
I-V interpeak latency
which of the following are acceptable filter settings for recording ABRs
10-2500Hz
which of the following would most likely result in an increased I-III interval
vestibular schwannoma
if a sound intensity is decreased from 80dB to 60dB then the sound pressure has been decreased by a factor of
10
the use of ER insert earphones results in
separating wave I from the stimulus artifact
what montage will help you discern waves IV and V in an ABR
Cz-contra ear
the sound stimulus intensity at the tympanic membrane depends on the
acoustic coupling between the sound stimulus generator and the ear