1/52
Looks like no tags are added yet.
isotope
same Z different N
isomer
metastable state
21H
deuteron
what do unstable nuclei want binding energy to be
as negative as possible
all atoms with Z>82 are
radioactive
artificial radioactivity produced as a byproduct of
nuclear fission
decay series of natural isotopes
uranium, actinum, thorium
activity
the rate of decay
mean life is useful for
calculating radiation dose for permanent implants
alpha decay
helium, slow, travel short
beta decay
electron or positron
neutron rich nuclei decay by
beta minus emission
neutron deficient nuclei undergo
positron emission or electron capture
beta plus used to produce radionuclides for
PET
electromagnetic decay is
isomeric transition (always preceded by another, leaving nucleus in excited state)
electromagnetic decay, energy is released by
photon emission, internal conversion
predominantly an artificially produced radioactive metal with all radioactive isotopes for tracers or functional scans
technetium
cobalt 60 decay scheme (ni60 energy released in excited levels to ground state via gamma ray emission)
beta disintegration, branching
secular equilibrium
half life parent much greater than daughter
transient equilibrium
half life parent greater than or equal to daughter
interstitial
surgical placement of sources using hollow needles
intracavitary
in body cavity
intraluminal
insertion of source into lumen of tube organs
surface brachy
in molds or plaques attached to superficial regions
0.4 to 2 Gy/Hr
LDR
12 Gy/Hr +
HDR
PDR
applied at frequent intervals (HDR equipment and LDR brachy)
problem with radium sources
alpha decay to radon
Cs137 and Co60 are
radium substitutes
sources are effectively useful for about
half of their half life
historical source strength specificiation
mass, activity, mg RA equiv
tradiational source strength specification
exposure rate
presently recommended source strength specification
air kerma
value of exposure rate constant depends on
radioisotope, source encapsulation
activity of some sources can be quoted into what terms
equivalent mass of radium
point source assumption does not hold when
not a point source, not isotropic
anisotriopic isodose lines distribution, is point source approximation okay for it?
safety but not tx planning
radial dose function
accounts for changes in exposure rate by distance and scatter
air kerma strength
brachytherapy source strength (air kerma rate at point along transverse axis)
quimby system for loading patterns
uniform loading, non uniform dose
paterson parker system
uniform dose, peripheral loaded
paterson parker implants
capped planar, uncapped planar, volume
paterson parker system classically treats
cervical cancer
HDR has a greater probability for
late effects (except for cervical, oar far away, allows rectum/bladder consistency)
vaginal cylinder most common for patients with
hysterectomy (5 in 5)
seed implants for
prostate LDR
electronic brachy
mini xray sources (short distance, less shielding, skin, intracavitary)
in sealed source brachy, anisotropy is greatest for
lower energy sources
anisotropy is highest along
axis of source (where ends are sealed)
anisotropy is also dependent on
thickness of encapsulation
low dose rate brachy activity
10 mci
high dose rate brachy activity
10 ci
co60 teletherapy activity
10,000 ci