1/8
Vocabulary flashcards covering the main components and operating functions of the AQUA type HW freshwater generator based on the lecture notes.
Production unit
A component built up of Titanium plates encased in a cast iron steel frame that carries out evaporation in its lower part, separation in its middle part, and condensation in its upper part.
Combined brine/air ejector
An ejector that extracts brine and non condensable gases from the process.
Ejector pump
A single-stage centrifugal pump that supplies the condenser with necessary seawater and the brine/air ejector with jet water, while providing a part of the seawater as feed water for evaporation.
Freshwater pump
A single-stage centrifugal pump that extracts the produced fresh water after condensing and pumps it to the freshwater tank.
Salinometer
A device mounted in the control panel that continuously measures the salinity of the produced freshwater, featuring an adjustable alarm set point and automatically diverting water back to the freshwater generator if salinity is too high.
Control panel
A panel containing motor starters with thermal overload relays, running lights for each pump, a salinometer, and voltage free NC / NOcontacts for remote alarm, prepared for remote start/stop of the pumps.
Lower part of the production unit plates
The section of the Titanium plates where evaporation takes place.
Middle part of the production unit plates
The section of the Titanium plates where separation takes place.
Upper part of the production unit plates
The section of the Titanium plates where condensation takes place.