what happens to electrons when we increase the KvP?

they have more energy and become faster

2
New cards

what is tube current measured in?

mA

3
New cards

what type of glass it the tube made of?

pyrex

4
New cards

what is the tube window?

thin area of glass where the x-ray photons exit

5
New cards

what is degassing?

tube is baked which expels the air out creating a vacuum

6
New cards

what are the two reasons a vacuum is needed?

unobstructed path and it slows down the burnout of the filament

7
New cards

what is in between the tube and the house and what does it do?

oil to insulate tube

8
New cards

what is the cathode assembly made up of?

filament, wire, and focusing cup

9
New cards

what is a focusing cup?

concave metal cup with a negative charge that surrounds filament to focus electrons into tight stream to anode

10
New cards

what is a focal spot?

spot on target that is being hit with electrons

11
New cards

what are the two filament sizes?

small and large to match the focal spots

12
New cards

does the focusing cup repel or attract electrons?

repel

13
New cards

what three wires are attached to the filament?

one attached to small filament, one attached to large filament, and one attached to both

14
New cards

what is the wire that is attached to both filaments called?

common wire

15
New cards

what does the common wire do?

carries high voltage to make the cathode negative and the anode positive

16
New cards

where do the wires connected to the filament come from?

filament circuit

17
New cards

what happens to the wires when you set a focal spot on the control panel?

2 of them will be activated

18
New cards

what is tube aging?

the filament getting thinner after many exposures

19
New cards

what can develop from tube aging?

tungsten deposits

20
New cards

where can tungsten deposits form?

window and walls

21
New cards

what happens to the wire when tungsten deposits are formed?

the diameter gets smaller which increases resistance and heat

22
New cards

how can we combat tube aging?

calibrate the filament current to control the amount of thermionic emission that takes place

23
New cards

what happens when deposits form on the window?

it acts as a filter that absorbs some photons and prevents them from exiting the tube (filtration)

24
New cards

what happens when deposits form on the wall?

stray electrons attract to the deposits which can puncture the tube, ruining the vacuum

25
New cards

the smaller the focal spot the ______ the image detail?

greater

26
New cards

what is the focal spot physically?

focal track

27
New cards

what is a stationary anode and who uses them?

still anode, dentistry

28
New cards

what is a rotating anode?

anode rotates

29
New cards

what kind of anode does diagnostic imaging use?

rotating

30
New cards

what are the three reasons tungsten is a good target material?

ability to conduct heat, high melting point, and high atomic number

31
New cards

what does it mean for tungsten to conduct heat well?

it spreads the heat to avoid melting the target

32
New cards

why is it good that tungsten has a high atomic number?

when electrons interact with it, high energy x-ray photons are produced

33
New cards

what does it mean to have a short exposure rating?

very high mA with a short exposure time all at once

34
New cards

what varies by each anode?

RPM, heat, and diameter

35
New cards

what does the edge of the anode look like?

angeled/bevelled

36
New cards

what is the most common target angle?

12

37
New cards

as target angle decreases, short exposure rating _______

increases

38
New cards

a large diameter anode can do what?

hold more heat

39
New cards

what is a fractional focus tube?

has a third focal spot and filament that is smaller than the small focal spot

40
New cards

why do we use rotating anodes?

better at distributing heat

41
New cards

what is the space charge effect?

space charge becomes so full of e- the repulsion puts e- back into the filament

42
New cards

what does every mA current allow for in regards to the space charge effect?

the space charge to have a maximum size cloud, beyond that e- are put back into filament

43
New cards

what does the line focus effect state?

because the target is angled down towards the IR, the effective focal spot is smaller than the actual focal spot

44
New cards

the _______ the target angle, the ________ the effective focal spot size

smaller, smaller

45
New cards

a small target angle and effective focal spot gives us what?

better image detail

46
New cards

the effective focal spot is _______ when projected towards the anode, and ________ when projected towards the cathode

smaller, larger

47
New cards

what is the space charge compensator?

keep mA constant when KvP changes

48
New cards

what does the mA control?

tube current

49
New cards

what does the Kv control?

energy of x-ray photons

50
New cards

what happens when Kvp is increases?

reduce in filament current, which reduces size of space charge, which gives us less electrons to travel from cathode to anode

51
New cards

what does pushing the button half down do?

supply current to filament and preps anode to speed

52
New cards

what does pushing the button completely down do?

take an exposure

53
New cards

what are the two filament precautions?

application of excessive current and prolonged heating from normal current (excessive rotoring)

54
New cards

describe the tube rating chart:

unique to each machine, tells us the max kv, ma, and time we can use

55
New cards

what things can happen to affect the anode?

a lot of hot exposures causing pitting on the target, or making a big exposure on a cold anode cracking it

56
New cards

what can happen with a crack in the anode?

photons can be absorbed and never leave the tube which lessens output

57
New cards

what characteristics have the best effect on tube rating?

full wave rectification, large focal spot, small target angle, fast anode rotation, and a high frequency generator

58
New cards

what is thermal capacity?

maximum number of heat units that a target can hold without melting

59
New cards

what are three ways the anode can cool off?

oil can spread heat around, cooling fan, and oil circulation around the tube

60
New cards

describe the anode cooling curve:

how many MINUTES we have to wait to max out our thermal capacity

61
New cards

what temperature does the tube housing have to be kept at?

90 degrees celsius or 200 degrees fahrenheit

62
New cards

what happens if the tube housing goes above the max temperature?

oil can boil and spill out onto patient