New cards

What does a Generator (Dynamo) do? (Energy wise)

Converts mechanical to electrical energy (electricity)

2
New cards

What does a basic electric motor do? (Energy wise)

Converts electrical energy into mechanical energy

3
New cards

These devices both contain basically the same components and operate on the same basic principles, but in reverse

Generator (Dynamo) & Basic Electric Motor

4
New cards

What are the two main components of motors and generators?

Conductor, Field Magnet

5
New cards

How does a generator work?

Source of energy moves a coil of wire (conductor/armature) near a stationary magnetic field and electricity is induced in the coil of wire

6
New cards

What law do generators work according to?

Faraday's Law

7
New cards

What type of current do generators produce?

Alternating current

8
New cards

What is one full rotation (360 degrees) of the armature called?

One cycle

9
New cards

How many cycles per second is produced of alternating current in the United States?

60 cycles/second or 60 Hz

10
New cards

With single-phase equipment, how many times does a sine wave drop to zero during one cycle?

Two times

60 cycles × 2 = 120

11
New cards

With single-phase equipment only ____x per second no X-rays are being produced

120x

12
New cards

Alternating current generators use a pair of what?

Slip Rings

13
New cards

Direct current generators use what?

Commutator ring

14
New cards

What are the 2 types of electrical motors?

  1. Direct current

  2. Alternating current motors (synchronous motors, induction motors)


15
New cards

Synchronous motors characteristics

  • Conducting coils turn at same speed as generator armature (60 Hz)

  • Timing device for steady speed (when needed)

  • Relatively weak


16
New cards

Induction Motors characteristics

  • Several pairs of electrogmagnets (stator)

  • Strong magnetic field

  • Increases power of motor

  • Runs at ANY desired speed

  • Located just OUTSIDE vacuum tube


17
New cards

2 parts of an x-ray induction motor

Rotor, Stator (electromagnets)

18
New cards

What type of induction do transformers use?

Mutual induction

19
New cards

Mutual induction definition

Electrical fields interacting with one another without contact

20
New cards

What type of current do transformers have to have to work?

Alternating current

21
New cards

Air Core Transformer

A simple arrangement of two coils of wire in close proximity

<p>A simple arrangement of two coils of wire in close proximity</p>
22
New cards

Open Core Transformer

  • Increased magnetic strength

  • More efficient than air core

  • Magnetic field loss at ends


<ul><li><p>Increased magnetic strength</p></li><li><p class="has-focus">More efficient than air core </p></li><li><p class="has-focus">Magnetic field loss at ends </p></li></ul><p></p>
23
New cards

Closed Core Transformer

  • Loss at ends minimized

  • Increased field strength

  • More expensive


<ul><li><p>Loss at ends minimized</p></li><li><p class="has-focus">Increased field strength </p></li><li><p class="has-focus">More expensive</p></li></ul><p></p>
24
New cards

Shell Type Transformer

  • Converged both inside and outside lines of force through iron core

  • Insulated wiring and wrapping of primary and secondary coils

  • Minimizes distance between coils and maximizes the couple effectiveness of induction

  • Most expensive, most advanced, most efficient

  • Used in x-ray generators


<ul><li><p>Converged both inside and outside lines of force through iron core</p></li><li><p class="has-focus">Insulated wiring and wrapping of primary and secondary coils </p></li><li><p class="has-focus">Minimizes distance between coils and maximizes the couple effectiveness of induction </p></li><li><p class="has-focus">Most expensive, most advanced, most efficient</p></li><li><p class="has-focus">Used in x-ray generators</p></li></ul><p></p>
25
New cards

X-ray generators most commonly use…

Laminated core, shell type transformers

26
New cards

Autotransformer

  • Self induction

  • Variable transformer

  • Has only one winding

  • Works according to Lenz's Law

  • Acts as step up or step down by varying # of turns that are “tapped”

  • Always placed between AC source and primary sude

  • Not suitable for high voltage transformers in x-ray machines

  • Suitable for controlling voltage on low-voltage side of x-ray circuit


<ul><li><p>Self induction</p></li><li><p class="has-focus">Variable transformer </p></li><li><p class="has-focus">Has only one winding</p></li><li><p class="has-focus">Works according to Lenz's Law</p></li><li><p class="has-focus">Acts as step up or step down by varying # of turns that are “tapped” </p></li><li><p class="has-focus">Always placed between AC source and primary sude </p></li><li><p class="has-focus">Not suitable for high voltage transformers in x-ray machines</p></li><li><p class="has-focus">Suitable for controlling voltage on low-voltage side of x-ray circuit</p></li></ul><p></p>
27
New cards

A rheostat (choke coil) also operates on the principle of self-induction and is a ________ resistor used to regulate filament current

Variable resistor

28
New cards

Variable resistor can also be called…

Rheostat, Potentiometer

29
New cards

What law's principles does self-induction operate by?

Ohm's Law

30
New cards

3 important transformers in an x-ray circuit

  1. Autotransformer

  2. High voltage step-up transformer

  3. Filament step down transformer (includes rheostat)


31
New cards

In terms of the x-ray circuit what is the autotransformer used for?

To select correct voltages to be sent to the high voltage transformer

32
New cards

In terms of the x-ray circuit, what is the high voltage step-up transformer used for?

To raise the incoming-line voltage to the kilo voltage range necessary for x-ray production

33
New cards

In terms of the x-ray circuit, what is the filament step-down transformer used for? What is the rheostat used for?

SDT: To decrease the incoming line voltage to the 5-15 volt and 3-5 amperage range used to heat the x-ray tube filament

Rhesotat: used to change the voltage or current values found in the filament circuit; regulates filament current

34
New cards

The number of turns of a wire in a primary coil is designed to be _________ from the number of turns in the secondary coil

Different

35
New cards

If the voltage is increased from primary to secondary coil, what type of transformer is it?

Step-up transformer

36
New cards

If the voltage is decreased from the primary to secondary coil, what type of transformer is it?

Step-down transformer

37
New cards

If the number of turns on the primary side is less than the numbers on the secondary side the voltage goes…

Up

38
New cards

If there are 10 turns of the secondary coil for every one turn of the primary coil, then the voltage generated in the secondary circuit will be…

10 times the voltage of the primary circuit

39
New cards

Why do we need to use alternating current for the process of mutual induction?

Constantly expanding and contracting magnetic lines of force induced in the primary coil provide the relative motion within the secondary coil necessary to induce current flow in the second coil

40
New cards

To induce a flow of current using a magnetic field, the magnetic field cannot be constant but must be…

Changing (motion)

41
New cards

What is the efficiency of a transformer?

95% efficient (5% power lost)

42
New cards

3 causes of power (heat) loss in a transformer

  1. I²R Loss (Copper loss)

  2. Hysteresis (lagging loss)

  3. Eddy Current (Eddies)


43
New cards

What causes I²R loss in a transformer?

Caused by inherent resistance to current flow found in all conductors (length, diameter, temperature, type)

44
New cards

How to minimize I²R loss in a transformer?

Use low-resistance wire (ex: large diameter copper)

Use high voltage and low amperage

45
New cards

How does hysteresis loss happen in transformers?

Changing alternating current continually magnetizes, demagnetizes, and re-magnetizes the core material which leaves some dipoles in original orientation (lagging)

46
New cards

Where does hysteresis loss in a transformer occur?

The core material

47
New cards

How can hysteresis loss be minimized in a transformer?

By using a core material such as silicon iron

48
New cards

What causes eddy current to occur in transformers?

Current opposing the magnetic field that induced them, creating a loss of transformer efficiency

49
New cards

Where does eddy current occur in transformers?

In the core

50
New cards

Eddy current is formed according to what law?

Lenz's law

51
New cards

How do you avoid eddy current in transformers?

Laminate the core to reduce the strength of eddies

52
New cards

Rectification

  • Creates one-way street

  • Permits electron flow in one direction

  • Alternating current converted to direct current

  • Solid-state diodes, SCRs, PNP junctions

  • Made of semi-conductive materials

  • Located on high-voltage side of circuit


53
New cards

By simply having a smaller surface area, the e- are more likely to jump the gap one way but less likely in the other direction due to larger surface area, creating a…

One-way street

<p>One-way street</p>
54
New cards

The 2 types of rectifiers

  1. Vacuum-tube rectifiers

  2. Solid-state semiconductor diodes


55
New cards

Vacuum-tube rectifiers are…

No longer used

56
New cards

Solid-state semiconductor diodes characteristics

  • Commonly used today

  • Numerous types but all operate in same manner


57
New cards

The terms rectifiers and solid-state diodes are…

Interchangeable

58
New cards

Examples of solid-state semiconductor diodes

P-N Junctions Semiconductors

Thyristor or silicon-controlled rectifier (SCRs) -more complex, useful for high-speed switching of primary voltage x-ray circuit

59
New cards

N-Type

  • Loosely bound e- that move freely between atoms conduction bands

  • Extra electron is available

  • Ex: arsenic covalent bonds with silicon


60
New cards

P-Type

  • e- traps made up of positively charged “holes” (P holes)

  • Attracts and hold e-

  • Leaves a need for additional e- hole

  • Ex: Gallium


61
New cards

What are N-Type and P-Type affected by?

Slight amounts of impurities that change their conduction properties

62
New cards

2 types of rectification

1. Half-Wave rectification

  1. Full-wave rectification


63
New cards

Half-wave rectification characteristics

  • At least 1 rectifier needed

  • On anode end of circuit

  • Only half of incoming alternating current is converted to pulsating direct current


64
New cards

In early days, what was half-wave rectification called?

Self-rectification

65
New cards

Full-wave rectification characteristics

  • Converts the opposing half of incoming electron flow so that electrons are always flowing in the same direction

  • At least 4 rectifiers bridged together

  • Used in modern x-ray equipment

  • Double efficiency = significant increase in power output capabilities

  • Ability to use higher mA and kVp settings


66
New cards

SCR is the GE trade name for….

A specific type of thyristor