1/65
The concepts for test 3
laminar, separated, turbulent, eddy currents
four basic types of airflow
leeward side
Air is sucked away from this side, creating negative pressure.
Bernoulli effect
In this effect, an increase in the velocity of a fluid decreases its static pressure. Because of this phenomenon, there is negative pressure at the constriction of a venturi tube.
Bernoulli effect
This effect can be made even stronger by designing roof openings to be like full venturi tubes.
stack effect
can exhaust air from a building by the action of natural convection. It will only exhaust air only if the indoor temperature difference between two vertical openings is greater than the outdoor temperature difference between the same two openings.
stack effect
The advantage of this effect over the Bernoulli effect is that is does not depend on wind.
stack effect
This effect causes the lower part of a building with an atrium to have a negative pressure and the upper part to have a positive pressure.
pressure distribution around the building; direction of air entering windows; size, location, and details of windows; interior partitioning details; site conditions
these factors determine pattern of airflow throughout a building
east-west
In most climates, the need for summer shade and winter sun calls for a building orientation with the long axis in this direction.
cross ventilation
This is very effective because air is both pushed and pulled through the building by a positive pressure on the windward side and a negative pressure on the leeward side.
fin walls
These can greatly increase the ventilation through windows on the same side of a building by changing the pressure distribution.
roof vents
These are typically used to lower attic temperatures . If, however, local winds are high enough, and the ventilator is large enough or high enough on the roof, these devices can also be used to ventilate habitable spaces.
single-loaded corridor
This is an alternative to the double-loaded corridor is the open single-loaded corridor, since it permits permits full cross ventilation.
clerestory windows
Single-story buildings can improve on the double-loaded corridor by using these instead of transoms.
night-flush
High openings are important for this kind of cooling where air must pass over the structure of the building.
passive cooling
this kind of cooling uses natural forces, energies, and heat sinks
hybrid
these systems use large pumps or fans that use significant amounts of energy
comfort ventilation
air passing over the skin creates a physiological cooling effect by evaporating moisture from the surface of the skin
night flush cooling
Cool night air can be used to flush out the heat from a building’s mass.
internal circulating fans
When indoor air temperature has risen above comfort zone, these are required to maintain comfort for additional hours (in relation to night flush cooling)
thermal mass
Critical for night flush cooling, because without it, there is no heat sink to cool the building during the day.
night vent cooling
In this strategy, thermal mass absorbs radiant heat during the day. The thickness of the material keeps the interior cool. Thermal mass releases heat at night to warm the interior.
double skin facades
also known as smart facades, can save energy and increase comfort by integrating all of the following strategies: passive solar, shading, daylighting, increased thermal resistance, natural ventilation
radiant cooling
At night, a building emits more long wave infrared radiation than it receives from the clear sky, creating a net heat flow to the sky. This type of cooling works well on clear nights byt is less efficient when humid. Clouds almost completely block the effect.
evaporative cooling
When water evaporates, it draws a large amount of sensible heat from its surroundings and converts this heat into latent heat in the form of water vapor. As sensible heat is converted to latent heat, the temperature drops but the humidity goes up. In hot and dry climates, the increase in humidity improves comfort.
direct evaporative cooling
If the water evaporates in the building or in the fresh air intake, the air will be not only cooled but also humidified.
indirect evaporative cooling
The building or indoor air is cooled by evaporation without humidifying the indoor air.
cool towers
passive evaporative coolers that act like reverse chimneys; As air enters the top of the tower, it is cooled, becomes denser, and sinks.
earth cooling
As soil depth increases, temperature fluctuations diminish due to the earth’s slow heating and cooling. This strategy is impractical unless the temperature difference is sufficiently large.
direct earth coupling
This occurs when earth-sheltered buildings have uninsulated walls in direct contact with the ground.
indirect earth coupling
For cooling, air is drawn through buried tubes, and the earth acts as a heat sink. To improve cooling performance, the surrounding soil can be cooled; shading from trees helps, as sunlight heats the soil.
solar chimney
Increases ventilation by enhancing the stack effect when the sun shines, especially on windless days; The sun heats air, increasing its buoyancy- warm air rises and exhausts out on the top, pulling cool air in at lower levels.
solar chimneys
In winter, these act as active solar space heaters.
roof integrated chimney
Use a raised roof plan or clerestory to create the solar-heated exhaust zone. (A type of solar chimney)
double roof
In hot climates, a structure located just above the roof shades the roof and allows warm air buildup between the roof and structure to escape. Incorporating this, separated by an air cavity, and extending the roofline to shade exterior walls will reduce cooling requirements.
shade
In climates with very hot summers and mild winters, this is more desirable than solar access.
2:1
For effective urban canyon shading, a height to width ratio of ____ or higher is generally recommended for maximizing street-level shade.
arcades and colonnades
When protection from rain as well as sun is desirable, these two things are frequently used.
south
When a choice of sites is available, this slope is still the best for most building types. In winter, it is the warmest for two reasons: it receives the most solar energy because it most directly faces the sun, and it experiences the least shading because objects cast their shortest shadows on these slopes.
north
This slope is the shadiest and coldest, while the hilltop is the windiest location.
cold
For this climate, South slopes maximize solar collection and are shielded from cold northern winds. Avoid the windy hill-tops and low-lying areas that collect pools of cold air.
hot and dry
For this climate, build in low-lying areas that collect cool air. If winters are very cold, build on the bottom of the south slope. If winters are mild, build on the north or east slope, but in all cases avoid the west slope.
hot and humid
For this climate, maximize natural ventilation by building on hilltops but avoid the west side of hilltops because of the hot afternoon sun.
solar window
The part of the sky dome through which useful solar energy passes: it includes the timer period during which more than 80 percent of the winter solar radiation is available.
south
Trees on this side of a building are problematic, because they can shade active solar, PV arrays, and block desirable daylight in the summer.
deciduous
These trees still block 30-60% of winter sun even without leaves.
solar-access boundary
When designing only one building on a site, solar access is best achieved by working with this.
shadow patterns
When designing a complex of buildings or a whole development, these are often useful for achieving solar access to all of the buildings. They are a composite of all shadows cast during winter hours when access to the sun is most valuable. (9 a.m. to 3 p.m.)
east-west
These streets provide the best orientation for the heating, cooling, and lighting needs of all building types.
north-south
With conventional development, these streets promote neither solar access in winter nor shading on east or west facades in summer.
uneven setbacks
Although lots facing east–west streets have the greatest potential for good solar access and shading, these benefits are not guaranteed. For example, _________ __________ can significantly reduce both winter sun and summer shading.
deep lots
These are better than shallow lots on east-west streets
solar zoning
This controls the shadows cast by a building on neighboring properties by defining the buildable volume on a site.
bulk-plane method
In this method, a plane slopes up from the north property line.
solar-envelope method
This method has the potential for not only ensuring high quality solar access, but also generating attractive architecture.
infiltration
This can cause over 50% of heat loss in older buildings on windy, open sites.
columns
Buildings raised on these create very windy conditions at grade level and are recommended only for climates without cold winters.
high-rise buildings
Even without underpasses, these often create such high winds at grade level that entrance doors are prevented from closing. This occurs because much of the wind hitting the facade of the building is deflected downward.
northern
To design a community or even a small development, it would be advantageous to place the higher buildings on this end. Not only will this arrangement block some of the cold northern wind, but it will also provide better access to the winter sun.
shadow
The higher the windbreak, the longer the ________.
ten
To get the full benefit of height, the width of the windbreak should be at least this many times the height.
pool of water
By placing this upwind or building downward from an existing lake, the air can be cooled by evaporation before entering a building. This strategy works best in hot and dry climates but can also be used in moderately humid areas.
transmission, infiltration, ventilation
Heat is lost from a building by these three methods:
thermal conductivity
This is a material’s ability to conduct heat, meaning how easily heat passes through it.
conductivity
This is a property of a single material, while the heat flow coefficient is the reciprocal of total resistance for a whole assembly like a wall or window.
albedo
the measure of a surface’s reflectivity of solar radiation