Presentations 23-30

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/65

flashcard set

Earn XP

Description and Tags

The concepts for test 3

66 Terms

1
New cards

laminar, separated, turbulent, eddy currents

four basic types of airflow

2
New cards

leeward side

Air is sucked away from this side, creating negative pressure.

3
New cards

Bernoulli effect

In this effect, an increase in the velocity of a fluid decreases its static pressure. Because of this phenomenon, there is negative pressure at the constriction of a venturi tube.

4
New cards

Bernoulli effect

This effect can be made even stronger by designing roof openings to be like full venturi tubes.

5
New cards

stack effect

can exhaust air from a building by the action of natural convection. It will only exhaust air only if the indoor temperature difference between two vertical openings is greater than the outdoor temperature difference between the same two openings.

6
New cards

stack effect

The advantage of this effect over the Bernoulli effect is that is does not depend on wind.

7
New cards

stack effect

This effect causes the lower part of a building with an atrium to have a negative pressure and the upper part to have a positive pressure.

8
New cards

pressure distribution around the building; direction of air entering windows; size, location, and details of windows; interior partitioning details; site conditions

these factors determine pattern of airflow throughout a building

9
New cards

east-west

In most climates, the need for summer shade and winter sun calls for a building orientation with the long axis in this direction.

10
New cards

cross ventilation

This is very effective because air is both pushed and pulled through the building by a positive pressure on the windward side and a negative pressure on the leeward side.

11
New cards

fin walls

These can greatly increase the ventilation through windows on the same side of a building by changing the pressure distribution.

12
New cards

roof vents

These are typically used to lower attic temperatures . If, however, local winds are high enough, and the ventilator is large enough or high enough on the roof, these devices can also be used to ventilate habitable spaces.

13
New cards

single-loaded corridor

This is an alternative to the double-loaded corridor is the open single-loaded corridor, since it permits permits full cross ventilation.

14
New cards

clerestory windows

Single-story buildings can improve on the double-loaded corridor by using these instead of transoms.

15
New cards

night-flush

High openings are important for this kind of cooling where air must pass over the structure of the building.

16
New cards

passive cooling

this kind of cooling uses natural forces, energies, and heat sinks

17
New cards

hybrid

these systems use large pumps or fans that use significant amounts of energy

18
New cards

comfort ventilation

air passing over the skin creates a physiological cooling effect by evaporating moisture from the surface of the skin

19
New cards

night flush cooling

Cool night air can be used to flush out the heat from a building’s mass.

20
New cards

internal circulating fans

When indoor air temperature has risen above comfort zone, these are required to maintain comfort for additional hours (in relation to night flush cooling)

21
New cards

thermal mass

Critical for night flush cooling, because without it, there is no heat sink to cool the building during the day.

22
New cards

night vent cooling

In this strategy, thermal mass absorbs radiant heat during the day. The thickness of the material keeps the interior cool. Thermal mass releases heat at night to warm the interior.

23
New cards

double skin facades

also known as smart facades, can save energy and increase comfort by integrating all of the following strategies: passive solar, shading, daylighting, increased thermal resistance, natural ventilation

24
New cards

radiant cooling

At night, a building emits more long wave infrared radiation than it receives from the clear sky, creating a net heat flow to the sky. This type of cooling works well on clear nights byt is less efficient when humid. Clouds almost completely block the effect.

25
New cards

evaporative cooling

When water evaporates, it draws a large amount of sensible heat from its surroundings and converts this heat into latent heat in the form of water vapor. As sensible heat is converted to latent heat, the temperature drops but the humidity goes up. In hot and dry climates, the increase in humidity improves comfort.

26
New cards

direct evaporative cooling

If the water evaporates in the building or in the fresh air intake, the air will be not only cooled but also humidified.

27
New cards

indirect evaporative cooling

The building or indoor air is cooled by evaporation without humidifying the indoor air.

28
New cards

cool towers

passive evaporative coolers that act like reverse chimneys; As air enters the top of the tower, it is cooled, becomes denser, and sinks.

29
New cards

earth cooling

As soil depth increases, temperature fluctuations diminish due to the earth’s slow heating and cooling. This strategy is impractical unless the temperature difference is sufficiently large.

30
New cards

direct earth coupling

This occurs when earth-sheltered buildings have uninsulated walls in direct contact with the ground.

31
New cards

indirect earth coupling

For cooling, air is drawn through buried tubes, and the earth acts as a heat sink. To improve cooling performance, the surrounding soil can be cooled; shading from trees helps, as sunlight heats the soil.

32
New cards

solar chimney

Increases ventilation by enhancing the stack effect when the sun shines, especially on windless days; The sun heats air, increasing its buoyancy- warm air rises and exhausts out on the top, pulling cool air in at lower levels.

33
New cards

solar chimneys

In winter, these act as active solar space heaters.

34
New cards

roof integrated chimney

Use a raised roof plan or clerestory to create the solar-heated exhaust zone. (A type of solar chimney)

35
New cards

double roof

In hot climates, a structure located just above the roof shades the roof and allows warm air buildup between the roof and structure to escape. Incorporating this, separated by an air cavity, and extending the roofline to shade exterior walls will reduce cooling requirements.

36
New cards

shade

In climates with very hot summers and mild winters, this is more desirable than solar access.

37
New cards

2:1

For effective urban canyon shading, a height to width ratio of ____ or higher is generally recommended for maximizing street-level shade.

38
New cards

arcades and colonnades

When protection from rain as well as sun is desirable, these two things are frequently used.

39
New cards

south

When a choice of sites is available, this slope is still the best for most building types. In winter, it is the warmest for two reasons: it receives the most solar energy because it most directly faces the sun, and it experiences the least shading because objects cast their shortest shadows on these slopes.

40
New cards

north

This slope is the shadiest and coldest, while the hilltop is the windiest location.

41
New cards

cold

For this climate, South slopes maximize solar collection and are shielded from cold northern winds. Avoid the windy hill-tops and low-lying areas that collect pools of cold air.

42
New cards

hot and dry

For this climate, build in low-lying areas that collect cool air. If winters are very cold, build on the bottom of the south slope. If winters are mild, build on the north or east slope, but in all cases avoid the west slope.

43
New cards

hot and humid

For this climate, maximize natural ventilation by building on hilltops but avoid the west side of hilltops because of the hot afternoon sun.

44
New cards

solar window

The part of the sky dome through which useful solar energy passes: it includes the timer period during which more than 80 percent of the winter solar radiation is available.

45
New cards

south

Trees on this side of a building are problematic, because they can shade active solar, PV arrays, and block desirable daylight in the summer.

46
New cards

deciduous

These trees still block 30-60% of winter sun even without leaves.

47
New cards

solar-access boundary

When designing only one building on a site, solar access is best achieved by working with this.

48
New cards

shadow patterns

When designing a complex of buildings or a whole development, these are often useful for achieving solar access to all of the buildings. They are a composite of all shadows cast during winter hours when access to the sun is most valuable. (9 a.m. to 3 p.m.)

49
New cards

east-west

These streets provide the best orientation for the heating, cooling, and lighting needs of all building types.

50
New cards

north-south

With conventional development, these streets promote neither solar access in winter nor shading on east or west facades in summer.

51
New cards

uneven setbacks

Although lots facing east–west streets have the greatest potential for good solar access and shading, these benefits are not guaranteed. For example, _________ __________ can significantly reduce both winter sun and summer shading.

52
New cards

deep lots

These are better than shallow lots on east-west streets

53
New cards

solar zoning

This controls the shadows cast by a building on neighboring properties by defining the buildable volume on a site.

54
New cards

bulk-plane method

In this method, a plane slopes up from the north property line.

55
New cards

solar-envelope method

This method has the potential for not only ensuring high quality solar access, but also generating attractive architecture.

56
New cards

infiltration

This can cause over 50% of heat loss in older buildings on windy, open sites.

57
New cards

columns

Buildings raised on these create very windy conditions at grade level and are recommended only for climates without cold winters.

58
New cards

high-rise buildings

Even without underpasses, these often create such high winds at grade level that entrance doors are prevented from closing. This occurs because much of the wind hitting the facade of the building is deflected downward.

59
New cards

northern

To design a community or even a small development, it would be advantageous to place the higher buildings on this end. Not only will this arrangement block some of the cold northern wind, but it will also provide better access to the winter sun.

60
New cards

shadow

The higher the windbreak, the longer the ________.

61
New cards

ten

To get the full benefit of height, the width of the windbreak should be at least this many times the height.

62
New cards

pool of water

By placing this upwind or building downward from an existing lake, the air can be cooled by evaporation before entering a building. This strategy works best in hot and dry climates but can also be used in moderately humid areas.

63
New cards

transmission, infiltration, ventilation

Heat is lost from a building by these three methods:

64
New cards

thermal conductivity

This is a material’s ability to conduct heat, meaning how easily heat passes through it.

65
New cards

conductivity

This is a property of a single material, while the heat flow coefficient is the reciprocal of total resistance for a whole assembly like a wall or window.

66
New cards

albedo

the measure of a surface’s reflectivity of solar radiation