1/59
What is an auxiliary system?
a septic system meant to serve a portion of a residence or adjoining facility
What is the difference between black water and gray water?
Black water comes into contact with excrement/organic matter while gray water doesn’t
What is a percolation rate?
The amount of time, in minutes/inch, necessary for water to seep into saturated soil at a constant rate
Connection should be made to a sewer system if it is available within what distance?
200 feet
A septic system is required for facilities that have occupants for how many hours a day?
2 hours a day
A facility must pretreat waste if the TSS and BOD5 exceeds what limit?
200 mg/L
For sites less than 3 acres, what is the max perc rate to be considered for a conventional system?
90
For sites over 3 acres, what is the max perc rate to be considered for a conventional system?
120
What is the range for DPH septic tanks?
1,000 - 10,000 gallons
What is the minimum retention time for a septic tank?
24 hours
Septic tank setback for wells, springs, sink holes
50 feet
Septic tank setback for bodies of water
25 feet
Septic tank setback from property lines
10 feet
Septic tank setback for swimming pools, foundations
10 feet
Septic tank set back from pressure water supply lines
10 feet
Septic tank setback for drainage ditches, embankments
15 feet
Drain field setback for wells, springs
100 feet
According to an MOA with EPD, if a spring is not used for its water, how far away does the drain field have to be?
50 feet
Drain field setback for water supply lines
10 feet
Drain field setback for property lines
5 feet
Drain field setback for pools, drainage ditches
15 feet
Drain field setback for bodies of water
50 feet
Given it has no garbage grinder, a 1000 gallon tank is suitable for what size house?
a house with 1-4 bedrooms
How many additional gallons are added for each bedroom over 4?
250 gallons
If a facility has a garbage grinder, what does the septic tank capacity increase by?
50%
What should you do if a water supply line comes within 10 feet of the absorption field?
Encase the water line and install it at least 12 inches over the top of the aggregate for the absorption lines
What is the minimum requirement for liquid depth in a septic tank?
36 inches
What is the minimum amount of freeboard necessary in a septic tank?
9 inches
The 1st compartment in a compartmented septic tank must be what capacity?
2/3 of the total capacity
How much soil cover should be over a septic tank?
minimum of 6 inches
When are risers necessary for a septic tank?
When the soil cover exceeds 12 inches
What is the minimum thickness for a concrete septic tank?
2½ inches for the sides and bottom, 3½ inches for the top
Each septic tank shall be marked with what and where?
A stamp with the manufacturer and capacity to the right of the outlet, 6 inches from top of the tank
What side of the tank does your filter go?
outlet
Riser walls have a minimum thickness of what?
2 inches
In a concrete distribution box, the inlet should be how much higher than the outlet?
2-3 inches
In a plastic distribution box, the inlet should be how much higher than the outlet?
1.5 inches
In what situations are dosing tanks used?
Where it is necessary to elevate the wastewater for further treatment or disposal
Where intermittent dosing of treatment units or subsurface absorption fields is desired
Where pressure distribution networks are used
When there are more than 500 linear feet of absorption trench, what is required?
A dosing tank and pump
When there are more than 1000 linear feet of absorption trench, what is required?
A dosing tank and alternating pump
A pump must have what to alert the owner of a malfunctioning system?
An alarm on a separate circuit from the pump switches
Absorption fields should not be placed in areas with a slope exceeding what?
25%
How far above the water table or other impervious layer should the absorption trench be?
24 inches
What is the minimum soil cover for absorption lines?
6-12 inches
Absorption lines should be how far apart, center to center?
7 feet
If a drain field were designed to allow for a replacement field to be placed in between the original absorption lines, how far apart would the absorption lines need to be, center to center?
16 feet
What is the maximum width of an absoroption line?
36 inches
Why should trench excavation not be done while the soil is saturated?
Damage to soil structure, such as smearing and compaction
Absorption field area is determined by what?
anticipated peak daily volume of treated waste (# of bedrooms)
waste stream characteristics
soil characteristics (perc rate and depth to water table)
A concrete foundation extending how far beyond the distribution box is required?
12 inches
Beginning 2 feet from the distribution box to the beginning of the absorption line, independent sewer lines shall be installed to provide a minimum downward grade change of what from the outlet to the beginning of the absorption line?
2 inches
Coming out from a distribution box, absorption lines shall be installed level or on a uniform grade of no more than how many inches of fall for the entire length of the individual absorption line?
4 inches
The level field method may be used when the slope of the land is what?
5% or less
With the level field method, how much lower is the beginning of the absorption line from the outlet of the septic tank?
6 inches minimum
For the serial distribution method, how much lower is the first absorption line from the septic tank outlet?
4 inches minimum
An alternating absorption field system may be considered when the percolation is what?
between 60 and 90
Chamber systems may not be constructed of what material?
Metal
When is a grease trap required?
When a facility produces over 50 mg/L of grease that could be introduced into the system
Does a grease trap go before or after the septic tank?
Before
What is the minimum size of a grease trap?
125 gallons