1/13
Looks like no tags are added yet.
What is Reverse Transcription (RT) PCR? How does it differ form traditional PCR?
Traditional PCR is only a qualitative assay: only tells us whether the DNA fragment (or gene) is present in the sample
Reverse Transcription (RT-PCR)
Uses RNA as the starting template (e.g., mRNA or viral RNA)
RNA is reverse transcribed into complementary DNA (cDNA) with the enzyme reverse transcriptase
An RNA–DNA hybrid is formed during cDNA synthesis
Reverse transcriptase possesses RNase activity and removes RNA from the RNA–DNA hybrid
DNA polymerase generates double-stranded DNA during subsequent PCR amplification
The resulting cDNA is amplified by PCR

What are the components of a Reverse Transcription PCR (RT-PCR) reaction
oglio dT primer, random primers, or specific primers
Reverse transcriptase
DNA polymerase
What are the application of RT-PCR
Detection of RNA viruses in clinical samples
Gene expression analysis
Detection of RNA transcripts produced by gene
Compare gene expression between different tissues or experimental conditions
What are the advantages of RT-PCR
Ability to reverse RNA into cDNA by RT-PCR has advantages:
RNA is single stranded and very unstable/ prone to degradation
OH group on pentose sugar is very reactive
DNA has only H so its more stable
Reverse transcription is often the first step in qPCR which quantifies RNA transcripts in biological samples
RT-PCR has a high sensitivity
RT-PCR is very specific when gene specific primers are used in reverse transcription
RT-PCR can be completed in one working day
Quantitative data analysis done through Quantitative Real-Time PCR (QPCR)
What is the process of Quantitative Real Time PCR (QPCR) and how does it differ from traditional PCR
A sensitive method for the detection of nucleic acids
Allows quantitative data analysis
May involve Reverse Transcription (Reverse Transcription quantitative real-time PCR (RT-qPCR))
Method of choice for the quantification of mRNA
Principle:
Uses fluorescent dyes that interact with the DNA as it is amplified
Carried out in a thermal cycler that illuminates each sample with a specific wavelength of light and continuously detects the fluorescence emitted by the fluorophore interacting with the DNA
What are the advantages of qPCR over standard PCR
Ability to visualize which reactions have worked in real-time
Regular PCR/RT-PCR data constitute only a snapshot of information
regarding the quantity of a given transcript in a cell or tissue.
QPCR does not require agarose gel electrophoresis
Allows truly quantitative analysis
Discriminate between RT-PCR, qPCR, and RT-qPCR
Reverse Transcription PCR (RT-PCR)
Reverse transcribe RNA into complementary DNA using reverse transcriptase
DNA Polymerase creates double-stranded DNA during PCR amplification
Resulting cDNA is amplified by PCR
Qualitative
Used if you start w/ isolated RNA and reverse transcribe it into DNA
Quantitative Real-Time PCR (qPCR)
Method for detection of nucleic acids
Allows quantitative data analysis
Uses fluorescent dyes that interact w/ DNA
Continuously detects fluorescence emitted by fluorophore interacting w/ DNA
Used if you start your quantitative PCR w/ isolated DNA
Reverse Transcription Quantitative Real-Time PCR (RT-qPCR)
A qPCR done with RT-PCR
Used if you couple reverse transcription to quantitative PCR
Can be done One Step or Two Step
One Step: Reverse transcriptase + DNA polymerase + sequence specific primers are added in one rxn
Two Step: Reverse transcriptase utilized to generate cDNA
(Oligo (dT), random or sequence specific primers are used for
Reverse Transcription/Step 1)
• Step 2: qPCR is carried out in a separate reaction/tube in
presence of DNA polymerase and sequence specific primers
Define Ct (cycle threshold). How do you visually interpret a QPCR cycle plot? How does Ct correlate to the starting target concentration of a sample?
A threshold level of fluorescence is set above the background but still within linear amplification for all plots
The threshold cycle “Ct”- defines the cycle number at which the fluorescent signal exceeds the threshold fluorescence
Ct is inversely proportional to the starting target DNA concentration of the sample
The greater the amount of initial DNA in the sample the lower the Ct value for that sample will be
Higher starting material (DNA) = lower Ct
Takes more cycle numbers to reach threshold

What is the principle of different types of detection (dyes and fluorescent reporters)
In both (SYBR green and TaqMan) methods, fluorescence intensity increases with each PCR cycle and is proportional to the accumulation of amplified DNA (amplicon)
Results are plotted as Fluorescence Intensity vs. # of cycles
Fluorescence indicates concentration
Threshold gives information about the starting material
The higher the initial amount of template DNA, the earlier the fluorescence signal increases and reaches the detectable threshold
Compare and contrast SYBR and TaqMan method for template visualization/detection
SYBR green:
Non-specific,
The fluorophore (SYBR green) intercalates with the DS DNA
Will not light up w/ SS DNA
No need for specifically labeled target probes
* Must run melting curve analysis and maybe a gel to rule out non-specific PCR products (i.e. Primer dimers)
TaqMan:
Specific detection of the target DNA sequence
Uses oligonucleotide probe that binds the SS DNA and has a reporter fluorophore (R) covalently attached to the 5’-end, and a quencher (Q) at the 3’-end
Quencher suppresses reporter’s fluorescence when the probe is intact
Relies on the 5’–3’ exonuclease activity of Taq polymerase to produce fluorescence
During DNA amplification, Taq polymerase cleaves the bound TaqMan probe
Cleavage separates R and Q will become physically separated, preventing further quenching and resulting in increased fluorescence
What is the purpose of using Melt Curve analysis and what is its principle
Used to assess the specificity and identity of qPCR amplification products when using SYBR green
SYBR intercalates ANY DS DNA during qPCR
Different PCR products have characteristic melting temperatures (Tm), depending primarily on their length and base composition (GC content).
Melting curve analysis is performed after the amplification cycles have been completed.
The temperature is gradually increased, causing double-stranded DNA (dsDNA) to denature into single strands.
As SYBR Green binds primarily to dsDNA, fluorescence decreases as DNA dissociates.
A sharp decrease in fluorescence occurs around the melting temperature (Tm) of each DNA product
Green dot line is Fluorescence (%)

How do you interpret the results of a Melt Curve Analysis
Each peak in the derivative melting curve corresponds to a DNA population melting over a particular temperature range
A single, sharp melting peak generally indicates one predominant amplification product.
Additional peaks may indicate non-specific amplification products or primer dimers.
Troubleshooting primer dimers
Decrease primer concentration
Increase the annealing temperature
Agarose gel electrophoresis can be used to further validate the size and specificity of PCR products
How can QPCR be quantified
Using absolute quantification (standard curve), Relative quantification, or ΔΔCt method
When do you use standard curve (absolute quantification) or relative quantification or ΔΔCt
Both convert Ct values into DNA concentration
Absolute quantification (standard curve)
Used when precise quantification of the initial DNA template concentration is required
A standard curve is generated by plotting the Ct values obtained from serial dilutions of DNA templates with known concentrations
Relative quantification
More commonly used approach
How mRNA amount changed when a sample is treated
Doesn’t get exact DNA concentration
The relative expression of the gene of interest (GOI) in an unknown sample is compared with its expression level in a control sample
Differences in Ct values between the unknown and control samples are used to calculate fold changes in gene expression relative to the control
ΔΔCt (2-ΔΔCt) method
An approach to calculate the relative fold change in gene expression between treated and untreated (control) samples using qPCR
Step 1: Calculate ∆Ct for each sample
Determine the difference between the Ct value of the gene of interest (GOI) and the housekeeping (reference) gene: ∆Ct = Ct (GOI) – Ct (reference)
Calculate this value for both treated and untreated samples
Step 2: Calculate ∆∆Ct
Determine the difference between the ∆Ct values of the treated and untreated samples: ∆∆Ct = ∆Ct (treated) – ∆Ct (untreated control)
Step 3: Calculate relative gene expression
Raise 2 to the power of minus ∆∆Ct to obtain the relative fold change in gene expression: Fold change= 2–∆∆Ct
Assumes amplification efficiency is 100%