Precision vs. accuracy (and how to report measurements)
Precision: How close a series of replicate measurements are to each other
Accuracy: how close a measured value is to the true or accepted value
How to report measurements:
(best estimate) ± (uncertainty) (units)
OR (average) ± (standard deviation)
Difference between random error (uncertainty) and systematic error
Random error
happens because of uncontrollable variables like environmental fluctuations and natural variations when estimating the last digit of an instrument reading
Can either skew the data too high OR too low past the true value (reduces precision)
mitigated by replication of trials
Systematic error
A consistent and repeatable deviation between an observed measurement and the true value
Caused by flaws in an instrument, experimental setup, consistently reading a meniscus from above, etc.
Skews measurements in one consistent direction, reducing accuracy
Mitigated through refined technique
How is relative uncertainty (relative standard deviation) calculated
(standard deviation) / measured value
How is relative error (percent error) calculated?
((measured - actual) / actual) x 100%
Possible sources of error in 102L experiments (THR, COL, RTK1-2, EQB, ST1-3)
THR (thermochemistry/calorimetry)
Systematic: heat loss from heat escaping to the surroundings (from imperfect styrofoam cup insulation)
Solid NaOH absorbing moisture (hygroscopic)
Random: fluctuations in temperature prove readings or slight variations in manual timing when adding reactants
COL (colligative properties/freezing point depression)
systematic: supercooling of the solvent or solution before freezing actually starts (distorting the freezing point pleateu)
incomplete dissolution of the solute before freezing point depression measurements
Random: minor fluctuations in digital temperature sensor readings
RK1-2 (Chemical kinetics - rates and rate laws)
Systematic: time delay between mixing reagents and starting spectrophotometer data collection
Random: minor instrumental drift in detector readings or slight variations in initial pipetting volumes
EQB (equilibrium)
systematic: fingerprints, smudges, or scratches on cuvettes increasing measured absorbance
Random: slight meniscus (curved part of where you read measurements) variations in the dilution preparation
ST1-3 (seawater titrations)
Systematic: air bubbles trapped in burette tip that flush out in titration
consistently reading above or below burette meniscus
overshooting titration equivalence point
Random: natural fluctuation in estimating last decimal place on burette when titrating