1/38
Vocabulary practice flashcards covering all portable safety, firefighting, oxygen, survival, and emergency equipment specifications from Middle East Airlines Cabin Crew Manual (CCM) Chapter 5.
Pre-Flight Safety Equipment Check
A mandatory check performed immediately after boarding at the beginning of the first flight, every crew takeover/aircraft change, or after the aircraft has been left unattended, ensuring all safety equipment is operational, serviceable, accessible, and stowed correctly.
Pre-Flight Discrepancy Reporting Procedure
The procedure requiring cabin crew to immediately report in person to the CCS any equipment discrepancy, unreadable expiry label, or security issue, after which the CCS informs Ground Engineering, notifies the Commander, and logs an entry in the CDL.
MEL (Minimum Equipment List)
The document held by the flight crew listing the minimum amounts of equipment considered safe for aircraft dispatch if pre-departure replacement or repair cannot be completed.
New Safety Equipment Introduction Requirements
Mandatory airline protocols requiring newly introduced equipment to be formally documented in the CCM, notified to crew and H/O Cabin Crew Training via email/memos/safety bulletins, and accompanied by full operational training.
Halon (BCF / Bromochlorodifluoromethane)
A liquefied extinguishing gas primarily used on Type B and C fires that suppresses combustion by chemically interrupting the flame chain reaction and smothering the fire.

AIR TOTAL Halon Fire Extinguisher
A Halon fire extinguisher consisting of a red cylinder, pressure gauge, carrying handle, release lever, nozzle, and safeguard lever, providing continuous agent discharge for 7seconds.

HAFEX (Halon Alternative Fire Extinguisher)
A Halon alternative extinguisher fitted with a safety pin, release lever, handle, nozzle, and bracket latch hooks, having an operating duration of approximately 9–10seconds from an optimal distance of 1.5–2meters.
PBE (Protective Breathing Equipment)
A portable breathing apparatus designed to supply a breathable atmosphere that protects crew members from smoke, carbon dioxide, toxic gases, and oxygen deficiency during firefighting.
Used PBE Post-Operation Protocol
The handling requirement to brush hair to disperse oxygen, let the hot unit cool, treat it as Dangerous Goods by placing it in a lavatory metal waste container, lock the lavatory (INOP LAV), and log it in the Cabin Defects Log.

AIR LIQUIDE PBE
A protective breathing device utilizing pressurized oxygen with an automatic impact activation system, a self-extinguishing neck seal, and an operational breathing duration of 15minutes.
AIR LIQUIDE Status Indicator
A visual serviceability check indicator on the PBE case that must be green; a red status indicates a damaged seal or oxygen leak, except after decompression when the PBE remains serviceable despite showing red.

OXYCREW & OXYCREW-CAS Smoke Hoods
Self-contained PBE units stowed above or inside the cabin attendant seat headrest with a useful life of 10years, a working duration of 15minutes, an anti-fog visor, and chemical oxygen generation initiated by exhaled carbon dioxide.
OXYCREW End of Operation Indications
Sensory indicators confirming oxygen depletion, consisting of cessation of oxygen flow sounds, rising internal temperature (reaching up to 40∘C), increased breathing resistance, and deflation of the hood.

Crash / Fire Axe
A tempered steel tool with a blade cutting edge for chopping panels/cables, a spike picking edge for punching access holes, and an insulated handle resistant to high voltages.

Fire Protective Gloves
Heavy-duty gloves providing thermal hand protection for cabin crew when handling hot surfaces, burnt wiring, or debris during an in-flight fire emergency.
Portable Oxygen Set
An emergency therapeutic oxygen unit consisting of a 310liter bottle, mask with metal fitting, and carrying strap, lasting 155minutes on Low Flow (2L/min) and 77minutes on High Flow (4L/min).
Mandatory Crew Station Oxygen Bottle
A portable oxygen cylinder maintained at each required cabin crew station charged to a minimum of 1500PSI with an attached mask for post-decompression use.
Medical Emergency Portable Oxygen Bottle Policy
Cabin oxygen bottles allocated for passenger first aid that may be used down to 500PSI; bottles dropping below 500PSI must be relocated to another approved stowage so they are not mistaken as serviceable.
Infant Oxygen Donning Protocol
The clinical procedure of administering high flow oxygen at 4LPM gently over an infant\'s face when their oxygen saturation drops below 90 measured by a pulse oximeter on the toe.

Portable Oxygen Set - Dual Outlet Type
A dual-fitting oxygen cylinder featuring a pressure gauge, ON-OFF knob, refill/relief valves, and separate continuous outlets calibrated for 2L/min (low) and 4L/min (high).

AVOX Portable Oxygen Bottle
A single-outlet portable oxygen unit equipped with an internal check valve, protective cover, and a rotary control knob calibrated for 2L/min or 4L/min delivery.
POCAs (Portable Oxygen Cylinder Assemblies)
Pre-requested passenger supplementary oxygen cylinders stored in a protective MEA Property flight case placed inside the aircraft left-hand (LH) closet, which must be discontinued once pressure drops to 100PSI.
Emergency Locator Transmitter - R406 SE
An emergency beacon that transmits distress signals for 50hours on civil (121.5MHz) and military (243MHz) frequencies, and for the initial 24hours on satellite (406.025MHz).
R406 SE Rotary Switch Settings
A four-position base switch comprising XMT (active distress broadcast), OFF (storage/transport), ARM (water-immersion sensor monitoring), and TEST (maintenance use only).

ELT RESCU406 SG
A buoyant, dual-frequency, water-activated survival beacon with GPS transmitting on 121.5MHz and COSPAS-SARSAT 406.040MHz for a minimum operational period of 48hours.
RESCU406 SG Activation Light Signals
The status indicator light that blinks amber every 2seconds for up to 3minutes, switches to green once GPS coordinates are acquired, and reverts to amber after 4hours of operation.
Pre-Flight Lifejacket Inspection Standard
The mandatory pre-flight sampling check requiring cabin crew to physically verify the integrity and seal of 10% of total aircraft lifejackets or 5 lifejackets in their assigned area, whichever number is greater.

Universal Life Jacket
A single-buoyancy chamber life vest equipped with a waist harness, oral inflation tube, manual CO2 cylinder with red toggle, vest locator light, and whistle, adapted for adults, children, and infants.
Infant Universal Life Vest Fitting
The fitting configuration where the lower preserver strap is passed through the infant\'s legs, routed around the back and over the left shoulder, using a primary buckle with a snap strap acting as secondary security.
Portable Flashlight
An explosion-proof, waterproof emergency light located at each cabin jump seat, featuring automatic ON/OFF magnetic retention bracket switching, a blinking red status LED, and a tamper shield.
Flashlight SOS-Signal
The standard emergency light sequence emitted by flashing three short signals (S), three long signals (O), and three short signals (S).

Megaphone - Non-LED Type
A battery-powered passenger address device verified during pre-flight checks by depressing the push-to-talk button to hear an audible click.

Megaphone - LED Type
A battery-powered megaphone equipped with a removable alarm siren pin, volume knob, and a handle that emits a green LED flash and speaker chirp when squeezed during pre-flight checks.
Slide Raft Signal Flares
Day/night pyrotechnic signals that discharge smoke during daylight or red flame at night, which eject an end plug after 2seconds and must always be fired downwind from the raft.

Signaling Mirror
An emergency visual signaling device aimed by sighting search aircraft through a center hole and tilting the mirror until the reflected light spot aligns with the target.
Sea Dye Marker
A survival pouch filled with highly visible bright dye, attached to the slide raft and immersed in sea water during daytime only on the up-wind side.

Demonstration Kit
A pre-flight briefing pouch containing an aircraft-specific safety card, demonstration life vest, demonstration oxygen mask, and demonstration seat belt.

Manual Release Tool (MRT)
A double-ended metal tool featuring a pointed end to manually open PSU oxygen compartments and medical panel covers, and a flat end to pull down door stoppers during mask verification.
Spare Safety Instructions Cards Provision
The requirement to carry a minimum of 25 spare safety briefing cards, stowed at the last business class row LHS on A320/A321 NEO aircraft and in the first LHS overhead compartment on A330 aircraft.