Revised National Plumbing Code of the Philippines

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/40

flashcard set

Earn XP

Description and Tags

Comprehensive practice flashcards in fill-in-the-blank style covering the Revised National Plumbing Code of the Philippines, including historical context, administration, general principles, fixture standards, water supply sizing, and drainage regulations.

41 Terms

1
New cards

On June 18, 1955, Republic Act No. 1378, otherwise known as the "Plumbing Law of the Philippines," was signed by President __________.

Ramon Magsaysay

2
New cards

In 1902, Master Plumber __________ became the first Chief of the Division of Plumbing Construction and Inspection in the City of Manila.

John F. Hass

3
New cards

The Revised Plumbing Code of 1999 was approved on December 21, 1999, by President __________.

Joseph Ejercito Estrada

4
New cards

All plumbing plans, drawings, specifications, and bills of materials must be submitted in __________ sets with each application for a permit.

six (6)

5
New cards

A plumbing permit becomes null and void if work is not commenced within one year from the date of the permit, or if work is suspended or abandoned for a period of __________ days.

120120

6
New cards

The Administrative Authority requires that every request for inspection be filed at least __________ working days before the inspection is intended.

three (3)

7
New cards

A request for inspection of replacement equipment or fixtures must be filed with the Administrative Authority not more than __________ hours after replacement work is completed.

7272

8
New cards

An unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood-level rim of any tank, vat, or fixture is known as an __________.

Air Gap, Water Distribution

9
New cards

A length of soil or waste stack corresponding in general to a story height, but in no case less than __________ meters, within which horizontal branches connect to the stack is a branch interval.

2.432.43

10
New cards

One fixture unit is defined as equivalent to a rate of flow of __________ liters per minute.

28.328.3

11
New cards

A structure is classified as combustible construction if any part of its structural framework will ignite and burn at a temperature of __________ or less.

756^\n\circ\text{C}

12
New cards

A soldered joint is obtained by joining metal parts with metallic mixtures or alloys that melt at a temperature below 427^\n\circ\text{C} and above __________.

149^\n\circ\text{C}

13
New cards

Brazed joints are made using alloys which melt at temperatures higher than __________ but lower than the melting temperature of the parts to be joined.

449^\n\circ\text{C}

14
New cards

Horizontal drainage pipes shall be run at a uniform slope of not less than __________ toward the point of disposal.

20 mm/m or 2%20\,\text{mm/m}\text{ or }2\%

15
New cards

Vertical installation of double sanitary tees may be used only when the barrel of the fitting is at least __________ pipe sizes larger than the largest side inlet.

two (2)

16
New cards

When installed vertically, plastic pipe stacks must be supported at every __________ interval.

one- (1) meter

17
New cards

Excavation trenches must be backfilled in thin layers of __________ above the top of the pipe with clean earth.

0.3 meter0.3\,\text{meter}

18
New cards

Water closet bowls for public use must be of the __________ bowl type equipped with open-front seats.

elongated

19
New cards

No water closet or bidet shall be set closer than __________ from its center to any side wall or obstruction.

0.375 meter0.375\,\text{meter}

20
New cards

No urinal shall be set closer than __________ center to center to any similar fixture.

0.6 meter0.6\,\text{meter}

21
New cards

A finished shower receptor dam or threshold shall be not less than 51 mm51\,\text{mm} nor more than __________ in depth measured from the top of the dam to the drain.

228 mm228\,\text{mm}

22
New cards

All shower compartments, regardless of shape, must have a minimum finished interior area of __________ and be capable of encompassing a 762 mm762\,\text{mm} diameter circle.

0.6 square meter0.6\,\text{square meter}

23
New cards

In the water test of a drainage and vent system tested in sections, each section must be filled with water to not less than a __________ head of water.

3-meter3\text{-meter}

24
New cards

In an air test of a drainage and vent system, air is forced into the pipe system until there is a uniform gauge pressure of __________ or sufficient to balance a column of mercury 254 mm254\,\text{mm} in height.

34.5 kPa34.5\,\text{kPa}

25
New cards

Faucets and diverters must be connected to the distribution supplies such that the hot water supply is located at the __________ side of the combination fittings.

left

26
New cards

Where local water pressure is in excess of __________, an approved-type pressure regulator preceded by an adequately sized strainer must be installed.

551 kPa551\,\text{kPa}

27
New cards

Each pressure relief valve on a water heating system shall be set at a pressure of not more than __________.

1034 kPa1034\,\text{kPa}

28
New cards

No building water service pipe shall be less than __________ in diameter.

19 mm19\,\text{mm}

29
New cards

Horizontal drainage piping must be provided with a cleanout at its upper terminal and at every __________ length or fraction thereof.

15 meter15\,\text{meter}

30
New cards

Cleanouts in drainage piping larger than 51 mm51\,\text{mm} must have a clearance of not less than __________ in front of the cleanout.

0.45 m0.45\,\text{m}

31
New cards

The minimum diameter of any pump discharge or discharge pipe from a sump having a water closet connected thereto is __________.

50.8 mm50.8\,\text{mm}

32
New cards

Fixture outlets shall not be connected to horizontal excreta drainage piping within __________ of any vertical to horizontal change of direction of a stack containing suds-producing fixtures.

2.4 meter2.4\,\text{meter}

33
New cards

No water having a temperature above __________ shall be discharged under pressure directly into any part of a drainage system.

60∘C60^\circ\text{C}

34
New cards

Each vent opening through the roof shall terminate not less than __________ from, or at least 0.9 meter0.9\,\text{meter} above, any openable window, door opening, air intake, or vent shaft.

3 meters3\,\text{meters}

35
New cards

Each soil or waste stack extending __________ or more stories above the building drain must be served by a parallel vent stack connected with a yoke vent at every fifth floor level.

ten (10)

36
New cards

Each plumbing fixture trap, except those with special conditions, must have a water seal of not less than 51 mm51\,\text{mm} and not more than __________ deep.

102 mm102\,\text{mm}

37
New cards

The vertical distance between a fixture outlet and the trap weir must never allow the tailpiece to exceed __________ in length.

0.6 meter0.6\,\text{meter}

38
New cards

For sizing rainwater piping around Manila and its environs, a rainfall intensity of __________ per hour is normally used.

102 mm102\,\text{mm}

39
New cards

Dome-type strainers on roof drains must have a minimum total net inlet area of __________ times the area of the outlet pipe to which they connect.

one and one-half (1-1/2)

40
New cards

The maximum distance between manholes on a building sewer line shall not exceed __________.

91 meters91\,\text{meters}

41
New cards

Caulked joints in bell-and-spigot cast iron soil pipe must be filled with molten pig lead to a depth of not less than __________.

25.4 mm25.4\,\text{mm}