Practice vocabulary flashcards covering medical radiation physics, biological effects of radiation, digital image formation, detector operations, diagnostic accuracy statistics, radiation therapy modalities, and radiation protection principles.
Linear Energy Transfer (LET)
The amount of energy deposited by ionizing radiation per unit distance along its travel path (keV/μm); higher LET radiation produces denser ionization tracks and greater biological damage.
Relative Biological Effectiveness (RBE)
A measure of the biological effectiveness of a test radiation relative to 250kVp x-rays, calculated as the ratio of the dose of 250kVp x-rays to the dose of test radiation required to produce the same biological end point (RBE=DosetestDose250kVp).
Fractionation
The delivery of a total radiation dose divided into multiple discrete increments separated by time intervals (such as 24hours) at the same dose rate, which spares healthy tissues by allowing repair and repopulation between sessions.
Protraction
The continuous delivery of a radiation dose over an extended duration at a reduced dose rate, which decreases biological effect compared to acute delivery by allowing ongoing cellular repair.
Oxygen Fixation Hypothesis
The radiobiological mechanism proposing that molecular oxygen reacts with radiation-induced free radicals in DNA to produce organic peroxides, permanently fixing chemical damage into an unrepairable state.
Deterministic Effect
A somatic radiation-induced response characterized by tissue injury whose severity increases with dose and which possesses a definite threshold dose below which the effect is not observed (e.g., epilation, erythema, sterility).
Stochastic Effect
A radiation-induced effect where the statistical probability of occurrence increases with dose without a threshold, while the severity of the condition is independent of the absorbed dose (e.g., carcinogenesis and hereditary mutations).
Background Equivalent Radiation Time (BERT)
A radiation risk communication concept that expresses the effective dose of a medical radiation procedure as the duration of natural background radiation exposure required to accumulate the same dose.
ICRP Radiological Protection Fundamentals
The three core principles established by the International Commission on Radiological Protection: justification (demonstrating net benefit over risk), limitation (complying with legal occupational and public dose limits), and optimisation (keeping doses As Low As Reasonably Achievable/Practicable, ALARA/ALARP).

Identify: Components of Radiation in Diagnostic Radiography
The three beam components encountered in radiography: primary radiation directed from the tube focal spot through the patient, scattered radiation emerging from Compton interactions within the patient, and leakage radiation penetrating the tube housing.
Primary Barrier
A protective structural partition designed to attenuate the direct, unscattered primary radiation beam before it enters occupied or uncontrolled spaces.
Secondary Barrier
A structural partition designed to attenuate scattered radiation emitted from the patient and leakage radiation penetrating the tube housing.

Identify: Radiation Therapy Bunker Layout
A treatment vault shielding design featuring primary barriers directly in line with beam trajectories, secondary barriers for scatter and leakage, and a maze entryway that attenuates scatter before the outer entrance door.
Bremsstrahlung
Radiative x-ray production caused by the deceleration and deflection of a high-speed projectile electron as it passes through the strong electrostatic Coulomb field of a target nucleus, generating a continuous spectrum of photon energies.
Characteristic X-ray
An x-ray photon emitted at a discrete, characteristic energy when an outer-shell electron transitions into an inner-shell vacancy created by the ionization of an orbital electron.
Binding Energy
The energetic threshold required to completely liberate an electron from its electrostatic bond to an atomic nucleus.
Direct Ionisation
Ionization occurring when incident charged particles or photons directly interact with and transfer sufficient energy to eject an orbital electron from an atom.
Indirect Ionisation
Ionization in an absorbing medium produced by fast secondary electrons that were previously liberated by primary uncharged ionizing radiation.
Main Chain Scission
The radiation-induced cleavage of the primary covalent backbone of a macromolecule, breaking it into smaller fragments and resulting in a measurable decrease in solution viscosity.
Cross-Linking
The formation of abnormal chemical bonds or side spurs linking adjacent macromolecular chains or loops after radiation-induced ionization, resulting in an increased solution viscosity.
Point Lesions
Radiation-induced disruptions or alterations of individual chemical bonds within a macromolecule that can cause subtle functional impairment or cellular mutation.
Free Radical
An uncharged atom or molecular fragment carrying an unpaired electron in its outer valence orbital, causing high chemical reactivity, a short lifetime (∼10−5s), and the ability to diffuse and cause indirect biological damage.
Single-Target Single-Hit Model (D37)
A survival model for simple biological targets where a single ionizing hit inactivates the target; a dose equal to D37 results statistically in 37% survival of the cell population.
Mean Lethal Dose (D0)
A parameter of the multi-target single-hit cell survival curve representing the reciprocal of the slope of the exponential linear terminal portion, indicating intrinsic radiosensitivity.
Quasi-Threshold Dose (Dq)
A parameter of the multi-target single-hit cell survival curve measured at the width of the shoulder region, reflecting a cell population's capacity to accumulate and repair sublethal radiation damage.
Matrix Size
The total number of discrete pixel rows and columns arranged in a two-dimensional digital image array (expressed as x×y).
Field of View (FOV)
The physical anatomical dimension or diameter of the patient area imaged and displayed in a reconstructed digital matrix.
Pixel Size Formula
The mathematical relationship determining digital spatial sampling dimensions: Pixel Size (mm)=Matrix Size (pixels)Image Size (mm).
Bit Depth
The number of binary bits allocated per pixel, which determines the total available greyscale gradations or tonal levels according to the formula 2n.
Spatial Resolution
The ability of an imaging system to distinguish two separate physical structures as distinct entities, typically quantified in line pairs per millimeter (lp/mm).
Image Histogram
A statistical graphical representation displaying the frequency of occurrence of each discrete pixel brightness or greyscale value across a digital image.
Histogram Equalisation
A digital image processing algorithm that redistributes pixel values across the available dynamic range to maximize image contrast across diagnostically relevant tissues.
Compression Ratio (CR)
The ratio expressing data reduction efficiency, defined as the number of bits in the original uncompressed image file divided by the number of bits in the compressed image file (CR=N1/N2).
Image Co-Registration
The spatial alignment and geometrical mapping of two or more medical imaging datasets acquired from different modalities, times, or patient positions to correlate functional and anatomical information.
Diagnostic Sensitivity
The probability that a diagnostic test correctly yields a positive finding in patients who actually have the disease (Sensitivity=TP+FNTP).
Diagnostic Specificity
The probability that a diagnostic test correctly yields a negative finding in patients who do not have the disease (Specificity=TN+FPTN).
Diagnostic Accuracy
The fraction of all diagnostic classifications (both positive and negative) that are correct relative to the total number of tested patients (Accuracy=TP+FP+TN+FNTP+TN).
Positive Predictive Value (PPV)
The probability that a patient who receives a positive diagnostic test result truly has the underlying disease (PPV=TP+FPTP).
Negative Predictive Value (NPV)
The probability that a patient who receives a negative diagnostic test result is truly free of the disease (NPV=TN+FNTN).
Band Gap
The forbidden energetic zone separating the valence band from the conduction band in a solid, governing electrical conductivity and optical excitation properties.
Scintillator
A luminescent material that absorbs ionizing radiation energy and de-excites by emitting optical light photons in the visible or ultraviolet spectrum.
Trap State
A metastable defect energy level located within the band gap of an insulator or semiconductor that immobilizes radiation-excited electrons until thermal or optical energy is applied to release them.
Detector Dead Time
The minimum duration required by a detection system following an event to reset and restore operating conditions, during which subsequent arriving photons cannot be registered.
Energy Resolution (FWHM)
The ability of a radiation detector to discriminate between photons of different energies, quantitatively expressed as the Full Width at Half Maximum (FWHM) of the characteristic photopeak divided by the central photopeak energy.

Identify: Thin-Film Transistor (TFT) Flat-Panel Detector Array
An active matrix readout board for digital radiography consisting of individual detector elements (pixels) containing a thin-film transistor (TFT) switch, a storage capacitor, and a sensing area addressed by gate lines and data lines.
Fill Factor
The percentage of a detector element's surface area that is actively sensitive to x-ray or light signal relative to its total structural area (Fill Factor=Total Del AreaSensitive Area×100%).
Direct Digital Radiography
A digital radiography system using a photoconductor (typically amorphous selenium, a-Se) that directly converts absorbed x-ray photons into electron-hole pairs collected by an electric field onto a TFT array.
Indirect Digital Radiography
A digital radiography system employing a scintillator (e.g., CsI:Tl or Gd2O2S:Tb) to convert x-rays into visible light, which is subsequently converted into an electrical charge by an amorphous silicon (a-Si) photodiode array.
Structured Scintillator
A scintillation crystal grown in needle-like columnar structures (such as CsI:Tl) oriented perpendicularly to the detector plane, reducing lateral light dispersion and improving spatial resolution.
Penumbra
The geometric unsharpness or partial shadow at the border of an x-ray image resulting from the finite, non-point dimensions of the focal spot (Penumbra=Focal Spot×SODOID).
Radiographic Grid Ratio
The ratio of the vertical height of lead attenuating strips (h) to the width of the radiolucent interspace material (D) separating them (r=Dh), defining scatter cleanup efficiency.
Collimation
The restriction of the primary radiation beam dimensions using lead shutters or diaphragms to confine the exposed field strictly to the anatomical region of interest, reducing patient dose and scatter.
Radiopharmaceutical
A diagnostic or therapeutic compound consisting of a radionuclide chemically bound to a pharmaceutical carrier molecule targeted to specific physiological pathways in vivo.
Photomultiplier Tube (PMT)
An electro-optical vacuum tube that converts scintillation light into photoelectrons at a photocathode and multiplies them across sequential dynodes via secondary emission, producing a measurable output pulse.

Identify: Nuclear Medicine Collimator Septa
A perforated lead multichannel collimator placed in front of an Anger camera scintillation crystal, where lead septa absorb off-axis photons to project a geometric image of gamma-emitting radioactive sources without optical lenses.
Pulse Height Analyzer (PHA)
An electronic sorting circuit in gamma cameras and scintillation detectors that establishes an energy window to reject Compton-scattered photons and accept only primary unscattered photopeak events.
Physiological Gating
The synchronization of nuclear medicine image acquisition or radiation therapy beam delivery with periodic physiological signals (such as an electrocardiogram R-wave or respiratory cycle) to eliminate motion artifacts.
Absolute Calibration
The standardized calibration procedure of measuring the output of a radiation therapy machine using a calibrated reference ionisation chamber positioned under defined reference conditions inside a water phantom.

Identify: Percentage Depth Dose (PDD) Curve
A central-axis depth-dose profile showing dose build-up from zero depth to a maximum (Dmax=100%) followed by an exponential attenuation drop-off with increasing depth in tissue.

Identify: Medical Linear Accelerator (Linac)
A radiation therapy machine comprising a stand, rotating gantry, electron gun, radiofrequency accelerating waveguide, bending magnet, target, and collimation system centered on an isocenter.
Gross Tumour Volume (GTV)
The demonstrable palpable or visibly imaged macroscopic extent and location of a malignant growth in radiation therapy planning.
Clinical Target Volume (CTV)
The anatomical tissue volume containing the GTV plus an expanded margin addressing subclinical microscopic malignant disease spread.
Planning Tumour Volume (PTV)
A geometric safety expansion encompassing the CTV and internal organ variations to account for daily patient positioning inaccuracies and mechanical machine tolerances.
Organs at Risk (OAR)
Non-target healthy anatomical structures whose radiation sensitivity significantly constrains radiation dose prescription and beam design during treatment planning.
Intensity Modulated Radiation Therapy (IMRT)
An external beam treatment delivery technique utilizing computer-controlled inverse planning to divide radiation beams into multiple non-uniform beamlets, yielding conformal dose envelopes around complex tumour geometries.
Volumetric Modulated Arc Therapy (VMAT)
An advanced rotational radiation delivery technique where a linac gantry rotates continuously around the patient while dynamically varying multileaf collimator apertures, dose rate, and rotational speed.

Identify: Proton Bragg Peak Depth-Dose Profile
The characteristic physical depth-dose curve of heavy charged particle beams displaying low entrance dose, a sharp localized ionization peak (Bragg peak) near the end of range, and zero exit dose beyond.
Brachytherapy
A radiotherapy modality involving the direct interstitial, intracavitary, or surface placement of sealed radioactive sources (e.g., 192Ir, 125I, 103Pd) within or adjacent to a tumour.
Electron Beam Therapy
Megavoltage radiation therapy using relativistic electron beams (6–20MeV) characterized by a high surface dose, a therapeutic plateau, and a sharp distal dose falloff that spares deeper normal tissues.

Identify: Thermoluminescent Dosimeter (TLD)
A passive radiation monitoring badge incorporating crystalline phosphors that store absorbed radiation energy within electron trap states, releasing light during thermal readout.
Ionisation Chamber
A gas-filled radiation detector operated at moderate voltages (50–300V) where an electric field collects all primary ion pairs without gas multiplication, producing a current directly proportional to exposure rate.

Identify: Townsend Avalanche in Gas Detectors
The cascade multiplication of charge carriers occurring when primary liberated electrons are accelerated by high electric fields to induce exponential secondary ionizations in a gas-filled detector.
Geiger-Müller (GM) Counter
A sensitive gas detector operated at high voltage where a single primary ionization triggers a complete Townsend discharge along the anode wire, generating uniform-amplitude electrical pulses independent of incident photon energy.
Electronic Equilibrium
The physical condition within an irradiated volume of interest where the number, kinetic energy, and species of secondary electrons entering the volume equals those exiting it.
Absorbed Dose (D)
The fundamental physical quantity defined as the mean energy (ΔE) imparted by ionizing radiation to an absorbing material of mass (Δm), expressed in Gray (1Gy=1J/kg).
KERMA (Kinetic Energy Released per unit MAss)
The sum of the initial kinetic energies of all charged ionizing particles liberated by uncharged ionizing radiation (such as x-rays or gamma rays) per unit mass of a medium (J/kg or Gy).
CEMA (Converted Energy per unit MAss)
The dosimetric quantity representing the electronic energy imparted by directly ionizing charged particles to matter per unit mass (J/kg or Gy).
Radiation Weighting Factor (wR)
A dimensionless modifying factor chosen by the ICRP to account for the relative biological effectiveness of different radiation types (wR=1 for photons and electrons, 2 for protons, 20 for alpha particles).
Tissue Weighting Factor (wT)
A dimensionless multiplier reflecting the proportional sensitivity of a specific human organ or tissue to stochastic radiation detriment relative to uniform whole-body irradiation, normalized such that ∑wT=1.00.
Equivalent Dose (H)
The radiation quantity calculated as the product of the average absorbed dose in a tissue (DT,R) and the radiation weighting factor (wR), summed over all radiation types (HT=∑RwR×DT,R), expressed in Sieverts (Sv).
Effective Dose (E)
The comprehensive dosimetric risk quantity defined as the tissue-weighted sum of equivalent doses across all irradiated organs (E=∑TwT×HT), expressed in Sieverts (Sv), representing overall stochastic health risk.