Medical Radiation Science: Physics, Dosimetry, Detection, and Radiation Protection

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/80

flashcard set

Earn XP

Description and Tags

Practice vocabulary flashcards covering medical radiation physics, biological effects of radiation, digital image formation, detector operations, diagnostic accuracy statistics, radiation therapy modalities, and radiation protection principles.

81 Terms

1
New cards

Linear Energy Transfer (LET)

The amount of energy deposited by ionizing radiation per unit distance along its travel path (keV/μm\text{keV}/\mu\text{m}); higher LET radiation produces denser ionization tracks and greater biological damage.

2
New cards

Relative Biological Effectiveness (RBE)

A measure of the biological effectiveness of a test radiation relative to 250 kVp250\,\text{kVp} x-rays, calculated as the ratio of the dose of 250 kVp250\,\text{kVp} x-rays to the dose of test radiation required to produce the same biological end point (RBE=Dose250 kVpDosetest\text{RBE} = \frac{\text{Dose}_{250\,\text{kVp}}}{\text{Dose}_{\text{test}}}).

3
New cards

Fractionation

The delivery of a total radiation dose divided into multiple discrete increments separated by time intervals (such as 24 hours24\,\text{hours}) at the same dose rate, which spares healthy tissues by allowing repair and repopulation between sessions.

4
New cards

Protraction

The continuous delivery of a radiation dose over an extended duration at a reduced dose rate, which decreases biological effect compared to acute delivery by allowing ongoing cellular repair.

5
New cards

Oxygen Fixation Hypothesis

The radiobiological mechanism proposing that molecular oxygen reacts with radiation-induced free radicals in DNA to produce organic peroxides, permanently fixing chemical damage into an unrepairable state.

6
New cards

Deterministic Effect

A somatic radiation-induced response characterized by tissue injury whose severity increases with dose and which possesses a definite threshold dose below which the effect is not observed (e.g., epilation, erythema, sterility).

7
New cards

Stochastic Effect

A radiation-induced effect where the statistical probability of occurrence increases with dose without a threshold, while the severity of the condition is independent of the absorbed dose (e.g., carcinogenesis and hereditary mutations).

8
New cards

Background Equivalent Radiation Time (BERT)

A radiation risk communication concept that expresses the effective dose of a medical radiation procedure as the duration of natural background radiation exposure required to accumulate the same dose.

9
New cards

ICRP Radiological Protection Fundamentals

The three core principles established by the International Commission on Radiological Protection: justification (demonstrating net benefit over risk), limitation (complying with legal occupational and public dose limits), and optimisation (keeping doses As Low As Reasonably Achievable/Practicable, ALARA/ALARP).

10
New cards
<p>Identify: Components of Radiation in Diagnostic Radiography</p>

Identify: Components of Radiation in Diagnostic Radiography

The three beam components encountered in radiography: primary radiation directed from the tube focal spot through the patient, scattered radiation emerging from Compton interactions within the patient, and leakage radiation penetrating the tube housing.

11
New cards

Primary Barrier

A protective structural partition designed to attenuate the direct, unscattered primary radiation beam before it enters occupied or uncontrolled spaces.

12
New cards

Secondary Barrier

A structural partition designed to attenuate scattered radiation emitted from the patient and leakage radiation penetrating the tube housing.

13
New cards
<p>Identify: Radiation Therapy Bunker Layout</p>

Identify: Radiation Therapy Bunker Layout

A treatment vault shielding design featuring primary barriers directly in line with beam trajectories, secondary barriers for scatter and leakage, and a maze entryway that attenuates scatter before the outer entrance door.

14
New cards

Bremsstrahlung

Radiative x-ray production caused by the deceleration and deflection of a high-speed projectile electron as it passes through the strong electrostatic Coulomb field of a target nucleus, generating a continuous spectrum of photon energies.

15
New cards

Characteristic X-ray

An x-ray photon emitted at a discrete, characteristic energy when an outer-shell electron transitions into an inner-shell vacancy created by the ionization of an orbital electron.

16
New cards

Binding Energy

The energetic threshold required to completely liberate an electron from its electrostatic bond to an atomic nucleus.

17
New cards

Direct Ionisation

Ionization occurring when incident charged particles or photons directly interact with and transfer sufficient energy to eject an orbital electron from an atom.

18
New cards

Indirect Ionisation

Ionization in an absorbing medium produced by fast secondary electrons that were previously liberated by primary uncharged ionizing radiation.

19
New cards

Main Chain Scission

The radiation-induced cleavage of the primary covalent backbone of a macromolecule, breaking it into smaller fragments and resulting in a measurable decrease in solution viscosity.

20
New cards

Cross-Linking

The formation of abnormal chemical bonds or side spurs linking adjacent macromolecular chains or loops after radiation-induced ionization, resulting in an increased solution viscosity.

21
New cards

Point Lesions

Radiation-induced disruptions or alterations of individual chemical bonds within a macromolecule that can cause subtle functional impairment or cellular mutation.

22
New cards

Free Radical

An uncharged atom or molecular fragment carrying an unpaired electron in its outer valence orbital, causing high chemical reactivity, a short lifetime (∼10−5 s\sim 10^{-5}\,\text{s}), and the ability to diffuse and cause indirect biological damage.

23
New cards

Single-Target Single-Hit Model (D37D_{37})

A survival model for simple biological targets where a single ionizing hit inactivates the target; a dose equal to D37D_{37} results statistically in 37%37\% survival of the cell population.

24
New cards

Mean Lethal Dose (D0D_0)

A parameter of the multi-target single-hit cell survival curve representing the reciprocal of the slope of the exponential linear terminal portion, indicating intrinsic radiosensitivity.

25
New cards

Quasi-Threshold Dose (DqD_q)

A parameter of the multi-target single-hit cell survival curve measured at the width of the shoulder region, reflecting a cell population's capacity to accumulate and repair sublethal radiation damage.

26
New cards

Matrix Size

The total number of discrete pixel rows and columns arranged in a two-dimensional digital image array (expressed as x×yx \times y).

27
New cards

Field of View (FOV)

The physical anatomical dimension or diameter of the patient area imaged and displayed in a reconstructed digital matrix.

28
New cards

Pixel Size Formula

The mathematical relationship determining digital spatial sampling dimensions: Pixel Size (mm)=Image Size (mm)Matrix Size (pixels)\text{Pixel Size (mm)} = \frac{\text{Image Size (mm)}}{\text{Matrix Size (pixels)}}.

29
New cards

Bit Depth

The number of binary bits allocated per pixel, which determines the total available greyscale gradations or tonal levels according to the formula 2n2^n.

30
New cards

Spatial Resolution

The ability of an imaging system to distinguish two separate physical structures as distinct entities, typically quantified in line pairs per millimeter (lp/mm\text{lp/mm}).

31
New cards

Image Histogram

A statistical graphical representation displaying the frequency of occurrence of each discrete pixel brightness or greyscale value across a digital image.

32
New cards

Histogram Equalisation

A digital image processing algorithm that redistributes pixel values across the available dynamic range to maximize image contrast across diagnostically relevant tissues.

33
New cards

Compression Ratio (CR)

The ratio expressing data reduction efficiency, defined as the number of bits in the original uncompressed image file divided by the number of bits in the compressed image file (CR=N1/N2\text{CR} = N_1 / N_2).

34
New cards

Image Co-Registration

The spatial alignment and geometrical mapping of two or more medical imaging datasets acquired from different modalities, times, or patient positions to correlate functional and anatomical information.

35
New cards

Diagnostic Sensitivity

The probability that a diagnostic test correctly yields a positive finding in patients who actually have the disease (Sensitivity=TPTP+FN\text{Sensitivity} = \frac{\text{TP}}{\text{TP} + \text{FN}}).

36
New cards

Diagnostic Specificity

The probability that a diagnostic test correctly yields a negative finding in patients who do not have the disease (Specificity=TNTN+FP\text{Specificity} = \frac{\text{TN}}{\text{TN} + \text{FP}}).

37
New cards

Diagnostic Accuracy

The fraction of all diagnostic classifications (both positive and negative) that are correct relative to the total number of tested patients (Accuracy=TP+TNTP+FP+TN+FN\text{Accuracy} = \frac{\text{TP} + \text{TN}}{\text{TP} + \text{FP} + \text{TN} + \text{FN}}).

38
New cards

Positive Predictive Value (PPV)

The probability that a patient who receives a positive diagnostic test result truly has the underlying disease (PPV=TPTP+FP\text{PPV} = \frac{\text{TP}}{\text{TP} + \text{FP}}).

39
New cards

Negative Predictive Value (NPV)

The probability that a patient who receives a negative diagnostic test result is truly free of the disease (NPV=TNTN+FN\text{NPV} = \frac{\text{TN}}{\text{TN} + \text{FN}}).

40
New cards

Band Gap

The forbidden energetic zone separating the valence band from the conduction band in a solid, governing electrical conductivity and optical excitation properties.

41
New cards

Scintillator

A luminescent material that absorbs ionizing radiation energy and de-excites by emitting optical light photons in the visible or ultraviolet spectrum.

42
New cards

Trap State

A metastable defect energy level located within the band gap of an insulator or semiconductor that immobilizes radiation-excited electrons until thermal or optical energy is applied to release them.

43
New cards

Detector Dead Time

The minimum duration required by a detection system following an event to reset and restore operating conditions, during which subsequent arriving photons cannot be registered.

44
New cards

Energy Resolution (FWHM)

The ability of a radiation detector to discriminate between photons of different energies, quantitatively expressed as the Full Width at Half Maximum (FWHM) of the characteristic photopeak divided by the central photopeak energy.

45
New cards
<p>Identify: Thin-Film Transistor (TFT) Flat-Panel Detector Array</p>

Identify: Thin-Film Transistor (TFT) Flat-Panel Detector Array

An active matrix readout board for digital radiography consisting of individual detector elements (pixels) containing a thin-film transistor (TFT) switch, a storage capacitor, and a sensing area addressed by gate lines and data lines.

46
New cards

Fill Factor

The percentage of a detector element's surface area that is actively sensitive to x-ray or light signal relative to its total structural area (Fill Factor=Sensitive AreaTotal Del Area×100%\text{Fill Factor} = \frac{\text{Sensitive Area}}{\text{Total Del Area}} \times 100\%).

47
New cards

Direct Digital Radiography

A digital radiography system using a photoconductor (typically amorphous selenium, a-Se) that directly converts absorbed x-ray photons into electron-hole pairs collected by an electric field onto a TFT array.

48
New cards

Indirect Digital Radiography

A digital radiography system employing a scintillator (e.g., CsI:Tl or Gd2O2S:Tb\text{Gd}_2\text{O}_2\text{S}:\text{Tb}) to convert x-rays into visible light, which is subsequently converted into an electrical charge by an amorphous silicon (a-Si) photodiode array.

49
New cards

Structured Scintillator

A scintillation crystal grown in needle-like columnar structures (such as CsI:Tl) oriented perpendicularly to the detector plane, reducing lateral light dispersion and improving spatial resolution.

50
New cards

Penumbra

The geometric unsharpness or partial shadow at the border of an x-ray image resulting from the finite, non-point dimensions of the focal spot (Penumbra=Focal Spot×OIDSOD\text{Penumbra} = \text{Focal Spot} \times \frac{\text{OID}}{\text{SOD}}).

51
New cards

Radiographic Grid Ratio

The ratio of the vertical height of lead attenuating strips (hh) to the width of the radiolucent interspace material (DD) separating them (r=hDr = \frac{h}{D}), defining scatter cleanup efficiency.

52
New cards

Collimation

The restriction of the primary radiation beam dimensions using lead shutters or diaphragms to confine the exposed field strictly to the anatomical region of interest, reducing patient dose and scatter.

53
New cards

Radiopharmaceutical

A diagnostic or therapeutic compound consisting of a radionuclide chemically bound to a pharmaceutical carrier molecule targeted to specific physiological pathways in vivo.

54
New cards

Photomultiplier Tube (PMT)

An electro-optical vacuum tube that converts scintillation light into photoelectrons at a photocathode and multiplies them across sequential dynodes via secondary emission, producing a measurable output pulse.

55
New cards
<p>Identify: Nuclear Medicine Collimator Septa</p>

Identify: Nuclear Medicine Collimator Septa

A perforated lead multichannel collimator placed in front of an Anger camera scintillation crystal, where lead septa absorb off-axis photons to project a geometric image of gamma-emitting radioactive sources without optical lenses.

56
New cards

Pulse Height Analyzer (PHA)

An electronic sorting circuit in gamma cameras and scintillation detectors that establishes an energy window to reject Compton-scattered photons and accept only primary unscattered photopeak events.

57
New cards

Physiological Gating

The synchronization of nuclear medicine image acquisition or radiation therapy beam delivery with periodic physiological signals (such as an electrocardiogram R-wave or respiratory cycle) to eliminate motion artifacts.

58
New cards

Absolute Calibration

The standardized calibration procedure of measuring the output of a radiation therapy machine using a calibrated reference ionisation chamber positioned under defined reference conditions inside a water phantom.

59
New cards
<p>Identify: Percentage Depth Dose (PDD) Curve</p>

Identify: Percentage Depth Dose (PDD) Curve

A central-axis depth-dose profile showing dose build-up from zero depth to a maximum (Dmax⁡=100%D_{\max} = 100\%) followed by an exponential attenuation drop-off with increasing depth in tissue.

60
New cards
<p>Identify: Medical Linear Accelerator (Linac)</p>

Identify: Medical Linear Accelerator (Linac)

A radiation therapy machine comprising a stand, rotating gantry, electron gun, radiofrequency accelerating waveguide, bending magnet, target, and collimation system centered on an isocenter.

61
New cards

Gross Tumour Volume (GTV)

The demonstrable palpable or visibly imaged macroscopic extent and location of a malignant growth in radiation therapy planning.

62
New cards

Clinical Target Volume (CTV)

The anatomical tissue volume containing the GTV plus an expanded margin addressing subclinical microscopic malignant disease spread.

63
New cards

Planning Tumour Volume (PTV)

A geometric safety expansion encompassing the CTV and internal organ variations to account for daily patient positioning inaccuracies and mechanical machine tolerances.

64
New cards

Organs at Risk (OAR)

Non-target healthy anatomical structures whose radiation sensitivity significantly constrains radiation dose prescription and beam design during treatment planning.

65
New cards

Intensity Modulated Radiation Therapy (IMRT)

An external beam treatment delivery technique utilizing computer-controlled inverse planning to divide radiation beams into multiple non-uniform beamlets, yielding conformal dose envelopes around complex tumour geometries.

66
New cards

Volumetric Modulated Arc Therapy (VMAT)

An advanced rotational radiation delivery technique where a linac gantry rotates continuously around the patient while dynamically varying multileaf collimator apertures, dose rate, and rotational speed.

67
New cards
<p>Identify: Proton Bragg Peak Depth-Dose Profile</p>

Identify: Proton Bragg Peak Depth-Dose Profile

The characteristic physical depth-dose curve of heavy charged particle beams displaying low entrance dose, a sharp localized ionization peak (Bragg peak) near the end of range, and zero exit dose beyond.

68
New cards

Brachytherapy

A radiotherapy modality involving the direct interstitial, intracavitary, or surface placement of sealed radioactive sources (e.g., 192Ir^{192}\text{Ir}, 125I^{125}\text{I}, 103Pd^{103}\text{Pd}) within or adjacent to a tumour.

69
New cards

Electron Beam Therapy

Megavoltage radiation therapy using relativistic electron beams (6–20 MeV6\text{--}20\,\text{MeV}) characterized by a high surface dose, a therapeutic plateau, and a sharp distal dose falloff that spares deeper normal tissues.

70
New cards
<p>Identify: Thermoluminescent Dosimeter (TLD)</p>

Identify: Thermoluminescent Dosimeter (TLD)

A passive radiation monitoring badge incorporating crystalline phosphors that store absorbed radiation energy within electron trap states, releasing light during thermal readout.

71
New cards

Ionisation Chamber

A gas-filled radiation detector operated at moderate voltages (50–300 V50\text{--}300\,\text{V}) where an electric field collects all primary ion pairs without gas multiplication, producing a current directly proportional to exposure rate.

72
New cards
<p>Identify: Townsend Avalanche in Gas Detectors</p>

Identify: Townsend Avalanche in Gas Detectors

The cascade multiplication of charge carriers occurring when primary liberated electrons are accelerated by high electric fields to induce exponential secondary ionizations in a gas-filled detector.

73
New cards

Geiger-Müller (GM) Counter

A sensitive gas detector operated at high voltage where a single primary ionization triggers a complete Townsend discharge along the anode wire, generating uniform-amplitude electrical pulses independent of incident photon energy.

74
New cards

Electronic Equilibrium

The physical condition within an irradiated volume of interest where the number, kinetic energy, and species of secondary electrons entering the volume equals those exiting it.

75
New cards

Absorbed Dose (DD)

The fundamental physical quantity defined as the mean energy (ΔE\Delta E) imparted by ionizing radiation to an absorbing material of mass (Δm\Delta m), expressed in Gray (1 Gy=1 J/kg1\,\text{Gy} = 1\,\text{J/kg}).

76
New cards

KERMA (Kinetic Energy Released per unit MAss)

The sum of the initial kinetic energies of all charged ionizing particles liberated by uncharged ionizing radiation (such as x-rays or gamma rays) per unit mass of a medium (J/kg\text{J/kg} or Gy\text{Gy}).

77
New cards

CEMA (Converted Energy per unit MAss)

The dosimetric quantity representing the electronic energy imparted by directly ionizing charged particles to matter per unit mass (J/kg\text{J/kg} or Gy\text{Gy}).

78
New cards

Radiation Weighting Factor (wRw_R)

A dimensionless modifying factor chosen by the ICRP to account for the relative biological effectiveness of different radiation types (wR=1w_R = 1 for photons and electrons, 22 for protons, 2020 for alpha particles).

79
New cards

Tissue Weighting Factor (wTw_T)

A dimensionless multiplier reflecting the proportional sensitivity of a specific human organ or tissue to stochastic radiation detriment relative to uniform whole-body irradiation, normalized such that ∑wT=1.00\sum w_T = 1.00.

80
New cards

Equivalent Dose (HH)

The radiation quantity calculated as the product of the average absorbed dose in a tissue (DT,RD_{T,R}) and the radiation weighting factor (wRw_R), summed over all radiation types (HT=∑RwR×DT,RH_T = \sum_R w_R \times D_{T,R}), expressed in Sieverts (Sv\text{Sv}).

81
New cards

Effective Dose (EE)

The comprehensive dosimetric risk quantity defined as the tissue-weighted sum of equivalent doses across all irradiated organs (E=∑TwT×HTE = \sum_T w_T \times H_T), expressed in Sieverts (Sv\text{Sv}), representing overall stochastic health risk.