Chapter 3.6 Storage Devices

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/29

encourage image

There's no tags or description

Looks like no tags are added yet.

30 Terms

1
New cards

HDD Design

Data Stored magnetically, Non-Volatile, Stored on Moving Platters, Actuator Arms Move Read-Write Heads

2
New cards

HDD 3.5in Form Factor

Desktops

3
New cards

HDD 2.5in Form Factor

Laptops, Mobile Devices

4
New cards

HDD 1.8in Form Factor

Ultrabooks, Compact Devices

5
New cards

HDD 5400 RPM Performance

Laptops

6
New cards

HDD 7200 RPM Performance

Workstations

7
New cards

HDD 10-15k RPM Performance

High Performance Servers

8
New cards

HDD Industry Standard Interface

SATA

9
New cards

SATA 1.0 Performance

150 Mbps

10
New cards

SATA 2.0 Performance

300 Mbps

11
New cards

SATA 3.0 Performance

600 Mbps

12
New cards

Hot Swapping

Replacing a Drive without Powering Down the System

13
New cards

SSD Design

No Moving Parts, Electronic Storage (NAND Chips), Non-Volatile

14
New cards

SSD Performance Benefits Compared to HDD

Smaller, Faster, More Shock Resistant, and Require less Power

15
New cards

SSD Overwriting Downside

SSDs cannot overwrite data directly, They must Erase Blocks of Data at a Time, Impacting Lifespan

16
New cards

NAND (Acronym)

Not AND, Logic Gate

17
New cards

SSD Form Factors

2.5in, M.2

18
New cards

M.2 Form Factor Design

Plugs Directly to Motherboard, Defined by its Dimensions (2280 = 22mm x 80mm), Always 22mm Wide

19
New cards

M.2 Connection Interfaces

MiniSATA or NVMe

20
New cards

NVMe (Acronym)

Non-Volatile Memory Express

21
New cards

NVMe (Use Case)

Optimized Interface for M.2 SSDs, Utilizes PCIe, Increased Speed Compared to SATA

22
New cards

PCIe (Acronym)

Peripheral Component Interconnect Express

23
New cards

Storage Type Used by Flash Drives, SD Cards and Multimedia Cards

NAND Chips

24
New cards

RAID (Acronym)

Redundant Array of Independent Drives

25
New cards

RAID (Use Case)

Combining Multiple Drives to Enhance Performance, Capacity, and Redundancy. Managed by a RAID Controller Card.

26
New cards

RAID 0 Striping (Use Case)

Striped Across Mulitple Drives, for Performance, Only Used when Data Loss is Acceptable

27
New cards

RAID 1 Mirroring (Use Case)

Provides Redundancy, Capacity is halved, Creates Identical Copy of Drive

28
New cards

RAID 5 Distributed Parity (Use Case)

Striped Across All Drives, Parity Information is Distributed Across All Drives, Combination of Redundancy and Performance

29
New cards

RAID 6 Doubled Parity (Use Case)

RAID 5’s Combination of Striping and Parity, 6 Can Withstand 2 Simultaneous Drive Failures Compared to RAID 5’s 1 Failure

30
New cards

RAID 10 Stripe of Mirrors (Use Case)

Combined Striping and Mirroring, Drives are Arranged as Mirrored Pairs, Tolerates failure of 2 Drives of Different Pairs, Expensive!