Building Envelope
The physical separator between the climate-controlled indoor living space and the unconditioned outdoor environment
Four Control Layers
1. Water control layer
2. Air control layer
3. Vapor control layer
4. Thermal control layer
Water Control Layer
Protects the structure against liquid water from rain, wind-driven rain, melting ice, and capillary action
Air Control Layer
Prevents air leakage caused by pressure differentials (wind, stack effect, and exhaust fans) through gaps, seams, and penetrations
Vapor Control Layer
Controls vapor drive (perm ratings)
Vapor Drive
The natural diffusion of water vapor moving directly through porous solid building materials from areas of higher humidity toward lower humidity
Perm Ratings
Materials are rated by how easily water vapor passes through them
Class I Vapor Barrier
Impermeable (≤0.1 perm)-Eg. Polyethylene, glass, foil-faced polyiso insulation
Class II Vapor Retarder
Semi-impermeable (0.1 to 1 perm)
-Eg. Extruded Polystyrene
Class III Vapor Retarder
Semi-permeable (1.0 to 10.0 perm)
-Eg. OSB Sheathing, Felt paper, Expanded Polystyrene)
Vapor Permeable
Vapor open (>10 perms)
- Eg. Spun housewrap, 1/2" interior drywall
Thermal Control Layer
Controls conductive heat loss in winter and heat gain in summer (measured by R-value); keeps internal wall surfaces warm above the dew point to prevent condensation
Vapor Diffusion alone:
Over a single heating season, water vapor diffusing through a solid 4ft x 8ft sheet of interior drywall transfers only 1/3 of a quart of water into the wall cavity
Air Leakage through a hole
Over a single heating season, a small 1in x 1in square hole in the drywall air barrier allows moving air to carry up to 30 quarts of water directly into the wall cavity
Winter Vapor Drive
Indoor air is warm and humidified; vapor drive pushes moisture from the inside toward the outside
Summer Vapor Drive
Outdoor air is hot and humid, while indoor air is cooled by air conditioning; vapor drive reverses, pushing moisture from the outside toward the inside
The "Double Vapor Barrier" Trap
Placing a vapor barrier on both sides of an enclosure traps moisture inside the wall indefinitedly, leading to structural rot and mold
Cold Climate Strategy
Modern high-performance walls use a vapor-permeable housewrap on the exterior so the wall can dry outward in winter, combined with continuous exterior rigid foam insulation to keep the OSB sheathing warm above the dew point, preventing condensation entirely
Interior Finish
1/2" Gypsum Drywall with latex paint
Interior Air/Vapor Retarder
Kraft-facing or smart vapor retarder membrane
Stud Cavity Insulation
Fiberglass batts, cellulose, or mineral wool
Structural Sheathing
7/16" OSB or Plywood sheathing
Continuous Exterior Insulation
Rigid foam board (XPS or Mineral Wool) to prevent thermal bridging and elevate sheathing temperature
Water-Resistive Barrier (WRB)
Taped housewrap (Vapor permeable, water tight)
Air Gap/Rainscreen
Furring strip gap allowing water to drain and air to dry the siding
Exterior Cladding (8th step)
Siding (Vinyl, Fiber-Cement, Wood, or Stucco)
Perm
A metric measuring a material's capacity to allow water vapor to pass through it
Thermal Bridging
Heat loss that occurs directly through conductive framing members (like wood or steel studs) that break insulation continuity
Ice and Water Shield
A self-adhering membrane installed along lower roof eaves in cold climates to protect against leaks caused by ice dams
1 inch
The gutter slope standard requires ____ for every 16 feet of run toward downspouts for gravity drainage
Bilco Door
A steel bulkhead assembly that provides direct exterior access to a home's basement
Drip Edge Flashing
Metal flashing installed at roof eaves and rakes to direct water into gutters and clear of the fascia board
Solar Heat Gain Coefficient
The fraction of solar radiation admitted through a window unit, directly impacting summer cooling loads
1/3 quart
How much moisture leaks through from diffusion according to the 30 quart rule
30 quarts
How much moisture leaks through from air leakage through a 1x1 inch hole
6 inches
Minimum clearance required between the ground and the bottom of wood, hardboard, or plywood panel siding to prevent moisture rot?
4
Minimum recommended roof slope for standard 3-tab asphalt shingles
U-factor
Measures the rate at which the unit conducts a non-solar heat flow
44"
Maximum sill height above floor
5.7ft^2