1
New cards

Building Envelope

The physical separator between the climate-controlled indoor living space and the unconditioned outdoor environment

2
New cards

Four Control Layers

1. Water control layer

2. Air control layer

3. Vapor control layer

4. Thermal control layer

3
New cards

Water Control Layer

Protects the structure against liquid water from rain, wind-driven rain, melting ice, and capillary action

4
New cards

Air Control Layer

Prevents air leakage caused by pressure differentials (wind, stack effect, and exhaust fans) through gaps, seams, and penetrations

5
New cards

Vapor Control Layer

Controls vapor drive (perm ratings)

6
New cards

Vapor Drive

The natural diffusion of water vapor moving directly through porous solid building materials from areas of higher humidity toward lower humidity

7
New cards

Perm Ratings

Materials are rated by how easily water vapor passes through them

8
New cards

Class I Vapor Barrier

Impermeable (≤0.1 perm)-Eg. Polyethylene, glass, foil-faced polyiso insulation

9
New cards

Class II Vapor Retarder

Semi-impermeable (0.1 to 1 perm)

-Eg. Extruded Polystyrene

10
New cards

Class III Vapor Retarder

Semi-permeable (1.0 to 10.0 perm)

-Eg. OSB Sheathing, Felt paper, Expanded Polystyrene)

11
New cards

Vapor Permeable

Vapor open (>10 perms)

- Eg. Spun housewrap, 1/2" interior drywall

12
New cards

Thermal Control Layer

Controls conductive heat loss in winter and heat gain in summer (measured by R-value); keeps internal wall surfaces warm above the dew point to prevent condensation

13
New cards

Vapor Diffusion alone:

Over a single heating season, water vapor diffusing through a solid 4ft x 8ft sheet of interior drywall transfers only 1/3 of a quart of water into the wall cavity

14
New cards

Air Leakage through a hole

Over a single heating season, a small 1in x 1in square hole in the drywall air barrier allows moving air to carry up to 30 quarts of water directly into the wall cavity

15
New cards

Winter Vapor Drive

Indoor air is warm and humidified; vapor drive pushes moisture from the inside toward the outside

16
New cards

Summer Vapor Drive

Outdoor air is hot and humid, while indoor air is cooled by air conditioning; vapor drive reverses, pushing moisture from the outside toward the inside

17
New cards

The "Double Vapor Barrier" Trap

Placing a vapor barrier on both sides of an enclosure traps moisture inside the wall indefinitedly, leading to structural rot and mold

18
New cards

Cold Climate Strategy

Modern high-performance walls use a vapor-permeable housewrap on the exterior so the wall can dry outward in winter, combined with continuous exterior rigid foam insulation to keep the OSB sheathing warm above the dew point, preventing condensation entirely

19
New cards

Interior Finish

1/2" Gypsum Drywall with latex paint

20
New cards

Interior Air/Vapor Retarder

Kraft-facing or smart vapor retarder membrane

21
New cards

Stud Cavity Insulation

Fiberglass batts, cellulose, or mineral wool

22
New cards

Structural Sheathing

7/16" OSB or Plywood sheathing

23
New cards

Continuous Exterior Insulation

Rigid foam board (XPS or Mineral Wool) to prevent thermal bridging and elevate sheathing temperature

24
New cards

Water-Resistive Barrier (WRB)

Taped housewrap (Vapor permeable, water tight)

25
New cards

Air Gap/Rainscreen

Furring strip gap allowing water to drain and air to dry the siding

26
New cards

Exterior Cladding (8th step)

Siding (Vinyl, Fiber-Cement, Wood, or Stucco)

27
New cards

Perm

A metric measuring a material's capacity to allow water vapor to pass through it

28
New cards

Thermal Bridging

Heat loss that occurs directly through conductive framing members (like wood or steel studs) that break insulation continuity

29
New cards

Ice and Water Shield

A self-adhering membrane installed along lower roof eaves in cold climates to protect against leaks caused by ice dams

30
New cards

1 inch

The gutter slope standard requires ____ for every 16 feet of run toward downspouts for gravity drainage

31
New cards

Bilco Door

A steel bulkhead assembly that provides direct exterior access to a home's basement

32
New cards

Drip Edge Flashing

Metal flashing installed at roof eaves and rakes to direct water into gutters and clear of the fascia board

33
New cards

Solar Heat Gain Coefficient

The fraction of solar radiation admitted through a window unit, directly impacting summer cooling loads

34
New cards

1/3 quart

How much moisture leaks through from diffusion according to the 30 quart rule

35
New cards

30 quarts

How much moisture leaks through from air leakage through a 1x1 inch hole

36
New cards

6 inches

Minimum clearance required between the ground and the bottom of wood, hardboard, or plywood panel siding to prevent moisture rot?

37
New cards

4

Minimum recommended roof slope for standard 3-tab asphalt shingles

38
New cards

U-factor

Measures the rate at which the unit conducts a non-solar heat flow

39
New cards

44"

Maximum sill height above floor

40
New cards

5.7ft^2

Minimum net clear opening area