RTH 1035 Modules 5 & 6: Physical Properties, Diagnostic Tests, and Patient Monitoring

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/41

flashcard set

Earn XP

Description and Tags

Comprehensive vocabulary flashcards covering the physical principles of oximetry, spectrophotometry, lung mechanics, and thoracic diagnostic imaging modalities from RTH 1035 Modules 5 and 6.

42 Terms

1
New cards

Spectrophotometry

The procedure for measuring the color or concentration of a solution by determining the amount of light absorbed in the ultraviolet, infrared, or visible light spectrum, based on the principle that every chemical substance possesses a unique pattern of light absorption.

2
New cards

Lambert-Beer Law

A fundamental physical law stating that the pattern of light absorption of a substance varies predictably with the amount and concentration of that substance present in a sample.

3
New cards

Absorption Spectrum

The characteristic and specific pattern of light absorption exhibited by an individual chemical substance across varying wavelengths of light.

4
New cards
<p>Isobestic Point</p>

Isobestic Point

A specific wavelength on a light absorption spectrum at which two or more distinct chemical species or forms of hemoglobin exhibit identical light absorbance coefficients.

5
New cards

Carboxyhemoglobin (HbCO\text{HbCO})

A stable complex of carbon monoxide and hemoglobin formed when colorless, odorless, and tasteless carbon monoxide (CO\text{CO}) gas binds to hemoglobin with 200–250×200\text{--}250\times the affinity of oxygen, competitively displacing oxygen and impairing tissue oxygen delivery.

6
New cards

Methemoglobin (metHb\text{metHb})

An altered form of hemoglobin produced by the oxidation of ferrous iron (Fe2+\text{Fe}^{2+}) to the ferric state (Fe3+\text{Fe}^{3+}), which increases the oxygen affinity of remaining binding sites and prevents effective release of oxygen to systemic tissues; commonly induced by topical anesthetics or inhaled nitric oxide.

7
New cards

Hemoximetry (Co-Oximetry)

An invasive laboratory analytic procedure requiring a whole blood sample that transmits four or more wavelengths of light through the specimen and a reference solution to calculate the exact concentrations of deoxygenated hemoglobin, oxyhemoglobin, carboxyhemoglobin, and methemoglobin, providing the most accurate measurement of arterial oxygen saturation (SaO2S_a\text{O}_2).

8
New cards

Photoplethysmography

An optical monitoring method that uses light transmission to detect minute cyclic changes in vascular volume produced by pulsatile arterial blood flow, used in combination with spectrophotometry in pulse oximetry.

9
New cards

Pulse Oximetry (SpO2S_p\text{O}_2)

A non-invasive clinical monitoring technology that estimates arterial oxyhemoglobin saturation by comparing absorbance across two distinct wavelengths of light—red (660 nm660\,\text{nm}) and infrared (940 nm940\,\text{nm})—with an expected accuracy of within ±4%\pm 4\% under normoxic conditions.

10
New cards

Pulse Oximetry Wavelengths (660 nm vs. 940 nm)

Pulse oximeters transmit two specific light wavelengths: Red light (660 nm), which is absorbed more by deoxygenated/reduced hemoglobin (dHb), and Infrared light (940 nm), which is absorbed more by oxyhemoglobin (HbO₂)

11
New cards

Pulse Oximetry Clinical Limitations

Reading accuracy (±4%) drops significantly when SpO₂ < 80%, or in the presence of low peripheral perfusion, hypothermia, motion artifacts, dark nail polish, ambient light interference, dyshemoglobins (HbCO/metHb), or dark skin pigmentation due to epidermal melanin light scattering.

12
New cards

Occult Hypoxemia

A severe arterial oxygen desaturation detectable via arterial blood gas analysis (SaO2S_a\text{O}_2) that remains undetected by standard pulse oximetry (SpO2S_p\text{O}_2); documented in medical studies to occur at three times higher frequency in Black patients due to epidermal melanin scattering infrared light.

13
New cards

Venous Oximetry (SvO2S_v\text{O}_2)

The measurement of mixed venous oxygen saturation (normal baseline ≈75%\approx 75\%) via an indwelling fiberoptic catheter placed in the pulmonary artery or vena cava using reflectance spectrophotometry to assess the adequacy of global cardiac output and systemic oxygen delivery.

14
New cards

Tissue Oximetry (StO2S_t\text{O}_2)

A non-invasive monitoring modality utilizing near-infrared spectroscopy (NIRS) across multiple wavelengths to continuously evaluate regional microvascular hemoglobin oxygen saturation in peripheral skeletal muscle or cerebral tissue.

15
New cards

Doppler Effect

The perceived change in frequency or wavelength of emitted waves occurring whenever there is relative motion between the wave-emitting source and an observer, causing wavelengths to shorten as the source approaches and lengthen as it recedes.

16
New cards

Hooke's Law

The principle of mechanical elasticity stating that the restoring tension generated within a stretched or compressed elastic structure is directly proportional to the magnitude of physical deformation imposed upon it.

17
New cards

Hooke's Law & Elastic Limit

  • Hooke's Law states that the tension developed when an elastic structure is stretched is directly proportional to the degree of deformation produced. The elastic limit is the threshold where added force causes permanent structural distortion and stretching is no longer proportional.


18
New cards

Elastic Limit

The upper threshold of mechanical stress beyond which an elastic structure ceases to obey Hooke's Law, resulting in permanent, non-reversible distortion or material failure.

19
New cards

Elasticity (Elastance)

The intrinsic physical tendency and property of an object or anatomical tissue to oppose expansion or deformation and return to its original resting dimensions once applied external forces are removed.

20
New cards

Lung Compliance

The measure of distensibility of the lungs and chest wall, functioning as the mathematical reciprocal of elastance, represented by the ratio Compliance=ΔVΔP\text{Compliance} = \frac{\Delta V}{\Delta P} and measured in mL/cmH2O\text{mL/cmH}_2\text{O}.

21
New cards

Attenuation (Radiography)

The degree to which the primary x-ray beam is scattered or absorbed as it passes through anatomical structures of differing physical densities before striking the detector.

22
New cards

Radiolucent

A radiographic term designating tissues or substances of low physical density (such as air in healthy lungs or the gastric bubble) that absorb negligible amounts of x-rays, allowing radiation to pass through and darken the image receptor to appear black.

23
New cards
<p>Radiopaque</p>

Radiopaque

A radiographic description for structures possessing high physical density or atomic weight (such as cortical bone or surgical metallic clips) that absorb a high fraction of incident x-rays, casting a pale gray or solid white silhouette.

24
New cards

The 4 Basic Chest X-Ray Densities

Air (Lungs, Trachea): Black (Radiolucent)

Fat (Subcutaneous tissue): Dark Gray

Soft Tissue/Water (Heart, Diaphragm): Medium Gray

Bone: White (Radiopaque) (Metal/Medical devices appear bright white)

25
New cards

Contrasting Densities & Silhouette Sign

Anatomical borders (such as the heart outline) are visible on a CXR only when placed next to a tissue of a different density (e.g., soft tissue heart surrounded by air-filled lungs). Loss of a normal border occurs when adjacent lung tissue fills with fluid or consolidation (silhouette sign)

26
New cards

Chest Radiograph Projections (PA vs. AP)

Posterior-Anterior (PA) is the standard upright view where X-rays travel back-to-front, minimizing cardiac silhouette magnification. Anterior-Posterior (AP) is typically a portable/supine bedside view where X-rays travel front-to-back, causing artificial enlargement of the heart outline.

27
New cards

Endotracheal Tube (ETT) Placement Verification

Correct ETT tip position on a chest radiograph is 3–5 cm3\text{--}5\,\text{cm} above the carina (or at the level of the T4–T5 thoracic vertebrae) to ensure equal bilateral lung ventilation and avoid accidental right mainstem intubation.

28
New cards

X-Ray Radiation Safety (ALARA)

Clinicians must keep radiation exposure As Low As Reasonably Achievable (ALARA) by minimizing repeat exposures, placing lead aprons or thyroid shields when appropriate, and maintaining a distance of at least 2 meters2\,\text{meters} (6 feet6\,\text{feet}) from the X-ray source during exposure7.

29
New cards

Picture Archiving and Communication System (PACS)

A specialized computerized medical imaging informatics network that digitally stores, organizes, transmits, and displays radiological studies, enabling image enhancement and side-by-side serial comparisons.

30
New cards

Computed Tomography (CT)

A diagnostic imaging technique that rotates an x-ray tube and opposite detector array rapidly inside a circular gantry around a supine patient to acquire multiple cross-sectional volumetric slices (1–5 mm1\text{--}5\,\text{mm} slice thickness).

31
New cards
<p>Computed Tomography Angiography (CTA)</p>

Computed Tomography Angiography (CTA)

A rapid CT imaging protocol that utilizes intravenous injection of iodinated radiopaque contrast dye at high rates to visualize pulmonary arterial vasculature and identify vascular filling defects like pulmonary emboli.

32
New cards

High-Resolution Computed Tomography (HRCT)

A dedicated thoracic computed tomography protocol that acquires ultra-thin cross-sectional slices (≈1 mm\approx 1\,\text{mm}) to maximize anatomical detail when evaluating the pulmonary interstitium, parenchyma, and small airways.

33
New cards

Magnetic Resonance Imaging (MRI)

A non-ionizing diagnostic imaging modality that places the patient in a powerful static magnetic field and transmits radiofrequency pulses to perturb hydrogen protons, capturing the emitted radio wave signals as protons relax back to alignment.

34
New cards

MRI Safety & Contraindications

Uses strong magnetic fields and radiofrequency pulses without ionizing radiation. Strictly contraindicated in patients or staff with cardiac pacemakers, ferromagnetic vascular clips, or metallic implants due to dangerous projectile risks and equipment dysfunction

35
New cards

Piezoelectric Effect

The physical process within an ultrasound transducer whereby applied electrical currents cause piezoelectric crystals to vibrate and generate high-frequency sound waves, and conversely, returning mechanical sound waves compress the crystals to generate measurable electrical voltages.

36
New cards

Acoustic Impedance

The resistance encountered by ultrasound waves propagating through a biological medium; discrepancies in acoustic impedance at tissue boundaries dictate the proportion of sound energy reflected back as an echo versus transmitted forward.

37
New cards
<p>A-Lines (Ultrasound)</p>

A-Lines (Ultrasound)

Repetitive, horizontal, equidistant hyperechoic reverberation lines appearing deep to the pleural line, representing a normal reverberation artifact of aerated, non-consolidated lung tissue.

38
New cards

B-Lines (Ultrasound)

Vertical, well-defined, hyperechoic 'comet-tail' ultrasound artifacts arising directly from the pleural line that travel down to the edge of the screen without fading, signifying extravascular lung fluid, pulmonary edema, or interstitial thickening.

39
New cards

Lung Sliding

The dynamic back-and-forth glistening movement between the visceral and parietal pleura during normal tidal respiration, commonly likened to 'ants on a log,' which effectively rules out a pneumothorax at the site of examination.

40
New cards

Ventilation-Perfusion (V/Q) Scan

A two-phase nuclear diagnostic study employing inhaled radioactive gas (xenon-133\text{xenon-133} or technetium-99m\text{technetium-99m}) and intravenous radioisotope-tagged macroaggregated albumin to map and compare regional gas distribution and pulmonary arterial blood perfusion.

41
New cards

Positron Emission Tomography (PET)

A functional nuclear medicine imaging technique that detects dual coincident annihilation gamma rays generated when positrons emitted by a radiotracer like fluorodeoxyglucose (FDG\text{FDG}) collide with surrounding electrons, highlighting hypermetabolic tissue such as active neoplasms.

42
New cards
<p>Electrical Impedance Tomography (EIT)</p>

Electrical Impedance Tomography (EIT)

A non-invasive, radiation-free bedside imaging system utilizing a 16-electrode belt placed between the 4th and 5th intercostal spaces that applies alternating high-frequency microcurrents to continuously record thoracic bioelectrical impedance variations and dynamically display regional lung ventilation.