1/32
A set of comprehensive vocabulary flashcards covering basic principles, terminology, thin layer chromatography (TLC), gas chromatography (GC), and high-performance liquid chromatography (HPLC).
Chromatography
A physical method of separation based on the difference in solubility or adsorption of a substance between a mobile phase and a stationary phase.
Chromatograph
The equipment used for separation using the technique of chromatography.
Chromatogram
The visual output of the chromatograph, typically a graph indicating the detector's response with respect to time.
Analyte
The component of the mixture which is required to be separated.
Eluent
The mobile phase of the mixture containing the analyte which enters the column.
Eluate
The mobile phase which leaves the column.
Retention Time (tR)
The characteristic time it takes for a particular analyte to pass through the system from the column inlet to the detector.
Mobile Phase
A solvent that flows through the supporting medium carrying the components of a mixture.
Stationary Phase
A layer or coating on the supporting medium that interacts with the analytes during chromatographic separation.
Supporting Medium
A solid surface on which the stationary phase is bound or coated.
Thin Layer Chromatography (TLC)
A technique used to isolate non-volatile mixtures through differential migrations across a thin layer of adsorbent (such as silica gel, aluminium oxide, or cellulose) spread over a glass, plastic, or aluminium foil sheet.
TLC Developing Chamber Setup
A sealed jar containing mobile phase, a moistened filter paper to maintain equal humidity, and a TLC plate placed with sample spots positioned above the mobile phase solvent level.
Retention Factor (Rf)
Calculated as the ratio of the distance traveled by the substance (solute) to the distance traveled by the solvent front.
Gas Chromatography (GC)
A chromatographic separation method where the sample is vaporized and injected into a column, carried by an unreactive gas mobile phase across an involatile liquid or solid stationary phase.
Gas Chromatograph Setup
An analytical system consisting of a carrier gas cylinder, flow controller, sample injection port, column oven containing the column, detector, and recorder or computer.
Carrier Gas
The mobile phase in gas chromatography, which must be chemically inert (e.g., N2, He, Ar, CO2), safe (non-inflammable), of high purity, and inexpensive.
Sample Injection Port (GC)
The hot zone of the column maintained at a temperature usually about 50∘C higher than the boiling point of the least volatile sample component, where samples are introduced using micro-syringes, gaslight syringes, or solid injection syringes.
Packed Columns (GC)
Gas chromatography columns made of stainless steel or glass, with lengths of 1.5m to 10m and internal diameters of 2mm to 4mm, packed with solid support material coated with stationary phase.
Capillary Columns (GC)
Gas chromatography columns made of fused silica with polyamide coating, having internal diameters of a few tenths of a millimeter and lengths between 25m and 60m.
Wall-Coated Open Tubular (WCOT) Column
A capillary column whose inner wall is directly coated with a liquid stationary phase.
Support-Coated Open Tubular (SCOT) Column
A capillary column whose inner wall is lined with a thin layer of support material (such as diatomaceous earth) onto which the stationary phase is adsorbed.
GC Detector
A transducer positioned at the column exit that converts physical quantities into electrical signals to quantify and identify eluting sample components.
GC Chromatogram
A visual output plotting detector response against time in seconds, showing distinct peaks corresponding to separated components in a sample mixture.
High Performance Liquid Chromatography (HPLC)
A separation technique involving the injection of a small liquid sample into a column packed with tiny particles (3 to 5μm) where components move under high pressure delivered by a pump.
HPLC System Components
An instrumental system comprising an HPLC solvent reservoir, high-pressure pump, sample injector, packed column, detector, waste container, and data acquisition computer.
HPLC Pump
A component that forces the mobile phase through the chromatograph at typical flow rates of 1 to 2mL/min and operating pressures of 6000 to 9000psi (400 to 600bar).
Solvent Degasser
An HPLC module that removes dissolved gases from the mobile phase to prevent air bubble formation, pressure fluctuations, pump malfunction, and signal noise.
Normal-Phase HPLC (NP-HPLC)
An HPLC mode using a polar stationary phase (such as silica) and a non-polar mobile phase (such as hexane or chloroform) where polar compounds are retained longer.
Reverse-Phase HPLC (RP-HPLC)
The most widely used HPLC mode, employing a non-polar stationary phase (such as C18 bonded silica) and a polar mobile phase (such as water mixed with methanol or acetonitrile) where non-polar compounds are retained longer.
Isocratic Elution
An HPLC elution mode where the mobile phase composition remains constant throughout the entire analysis.
Gradient Elution
An HPLC elution mode where the mobile phase composition gradually changes over time during the run.
Dead Time (t0)
The time required for an unretained molecule of the mobile phase to pass completely through the chromatographic column.
Liquid Chromatogram Peak Parameters
A graph displaying detector signal intensity versus time, showing dead time (t0), retention time (tR), peak height (h), and peak area (A) relative to the baseline.