1/17
Looks like no tags are added yet.
APU – Maximum Altitude
Altitude | Visual memory | APU load |
|---|---|---|
10,000 ft | ✈ + 🌬 + ⚡ | Bleed + Electrical — Inflight |
15,000 ft | 🛬 + 🌬 + ⚡ | Bleed + Electrical — Ground |
17,000 ft | 🌬 only | Bleed only |
41,000 ft | ⚡only | Electrical only |
Memory:
10 = 2 felgaw→ 15 = 2 ard
17 = Bleed → 41 = Electrical.

APU – Limitations
Ground air connected + Isolation Valve ✅OPEN | APU Bleed CLOSED❌ |
ENG 1 Bleed Valve ✅OPEN | APU Bleed CLOSED❌ |
Isolation valve ✅ + ENG 2 Bleed Valve ✅OPEN | APU Bleed CLOSED❌ |
Engine start | APU Bleed may be OPEN✅, but engine power Must be IDLE |
3 consecutive aborted starts | Wait 15 minutes for cooling🥶🧊 |
Before using APU as bleed source | Run for 2 full minutes for stabilization😑 |
Memory flow:
3 conditions → CLOSED
Engine start → OPEN allowed, IDLE only
3 aborted starts → 15 min cooling
Before bleed use → 2 min stabilization

APU Operation
Honeywell Allied Signal 131-9 (B)
Self-contained gas turbine engine installed inside a fireproof compartment in ac tail.
Supplies
1. Bleed Air 🌬
Engine starting.
on ground: Both air conditioning packs
in flight: One pack
2. APU Electrical Generator ⚡
Provides auxiliary AC powers→both Transfer Buses on ground or in flight.
APU Starter Generator – AMM
Altitude | Maximum output |
|---|---|
Sea level – 32,000 ft | 90 kVA |
32,000 – 41,000 ft | 66 kVA |
As Altitude⬆→Output⬇: 90 → 66 kVA.
APU EGT (Exhaust Gas Temperature)
Range: 0–1→100°C
Starter Duty Cycle
Max. ON time: 120 sec.
APU Normal Start – Starter Duty Cycle
Starter ON time | 120 sec (2 min) per attempt |
Consecutive aborted starts | Maximum 3 attempts |
Cooling / OFF time | 15 min after 3 consecutive aborted starts |
Memory: 2 min per attempt → 3 aborted starts → 15 min cooling.
APU Shutdown
APU switch OFF → APU continues 60 seconds→ 🔄auto. shuts down
This provides an automatic 60-second cooling period.
APU Starting Power
Electrical power for APU starting comes from:
External power generator available: AC Transfer Bus 1.
No external power generator: A/C battery.
APU Bleed Air switch Should OFF Prior to APU Start
Battery Switch – OFF
on ground or in flight:→ ❌Power to ECU (Electronic Control Unit) lost → APU🔄Automatic shuts down.
APU EGT Indicators→Remains powered for 5 minutes after
🔄Automatic APU Shutdown Faults
Caused by Any of these indicators:
LOW OIL PRESSURE
OVERSPEED
FAULT
After selecting APU switch OFF:
If a light is illuminated→extinguishes after 5 minutes.
due to:
loss to Electronic Control Unit (ECU)
Shutdown Sequence
As APU speed ⬇decreases sufficiently:
Fuel valve❌closes
Inlet door ❌closes
Fuel valve failure to close → FAULT light illuminates after 30sec.
. Automatic shutdown → EGT remains 5 min → Speed decreases → Fuel valve + inlet door close → If fuel valve fails, FAULT after 30 sec.
APU Fuel Feed – Normal Operation
1. Normal Fuel Supply depends on AC fuel pump operation:
✅: Fuel supplied from Left side of fuel manifold.
❌: APU is suction-fed from Main Tank 1.
2. Center Tank Fuel – Before T/O
if Fuel> 453 kg → Turn LEFT CTR pump ON→Prevent fuel imbalance
3. Extended APU Operation on Ground
if needed on ground & a/c buses are powered by AC→ Position an AC-powered fuel pump ON
Purpose: Extend service life of APU FCU (Fuel Control Unit).
Memory links:
AC pumps ON → Left fuel manifold.
AC pumps OFF → Suction from Main Tank 1.
CTR > 453 kg → Left CTR pump ON.
Extended ground operation → AC fuel pump ON → Protect FCU.
Battery-Only Electrical Power
→ APU operation is required to restore electrical power.
Start attempts are NOT recommended above 25,000’
Memory: All generators OFF → Battery only → Start APU
(avoid attempts above 25,000 ft).
ECU (Electronic Control Unit) – Automatic Shutdown Protection
when it detects:
High oil temperature
Overspeed
Low oil pressure
EGT exceedance
APU Fire
Fuel Control Unit failure
Other system faults monitored by ECU
Memory grouping:
Engine protection: High oil temp, Overspeed, Low oil pressure, EGT exceedance.
Fire protection: APU Fire.
System protection: FCU failure + other ECU-monitored faults.
APU Operation – Electrical Requirements
All 3 conditions must be met:
APU FIRE switch on (Overheat/Fire Panel) → IN ✅
APU Fire Control Handle (on APU Grnd Cntrl Panel) → IN ✅
Battery switch → ON ✅
Memory: 2 Fire IN + Battery ON.
APU 🔄️Automatic Load Shedding
3 shedding cases / priorities:
1. During Engine Start: Electrical load shed first ⚡
→ Priority for Bleed Air 🌬
2. All Other phases (not during start): Bleed Air shed first 🌬
→ Priority for Electrical Power ⚡
3. Electrical Load Shedding (Ground or Inflight)
Quick Memory
START → Save Bleed Air.
OTHER PHASES → Save Electrical Power.
Electrical shedding → Check Electrical Chapter.
Cockpit Pre-flight Procedures (OM-A Ch.14)
AC unit connected: Start APU 10 minutes before ETD.
NO AC unit available: Start APU before passenger boarding.
Parking Phase – Save APU Lifetime
- GPU (Ground Power Unit) connected to a/c + APU no longer needed: → Shut down APU after 5 minutes
Supplementary Electrical Power Down
- After APU GEN OFF BUS light extinguishes: → Wait approximately 2 min before switching BATTERY OFF.
Situation | Timing |
|---|---|
AC unit available → Before ETD | 10 min |
No AC unit → Before boarding | Before pax boarding |
GPU connected + APU no longer needed | 5 min |
GEN OFF BUS light extinguished → BATTERY OFF | Wait 2 min |