1/23
Vocabulary flashcards covering organic chemistry lab policies, safety rules, standard organic glassware identification, and the principles and techniques of liquid-liquid extraction.
Liquid-Liquid Extraction
A separation method (also known as solvent extraction or partitioning) used to separate compounds based on their relative solubility differences between two immiscible liquid phases.
Partition Coefficient (Keq/K)
The equilibrium ratio of the concentration of a solute in the organic solvent layer to its concentration in the aqueous solvent layer: K=Concentration of Compound in H2OConcentration of Compound in Organic.
"Like Dissolves Like"
A general chemical principle used to predict solubility, indicating that polar compounds dissolve preferentially in polar solvents (such as water) and non-polar compounds dissolve preferentially in non-polar organic solvents.
Extraction Layer Ordering Rule
The physical rule determining layer placement in a separatory funnel by density: the liquid with higher density forms the bottom layer, meaning halogenated organic solvents (e.g., methylene chloride, density 1.33g/mL) sit below water (1.000g/mL), while less dense non-halogenated solvents (e.g., diethyl ether, density 0.706g/mL) float on top.
Venting
The laboratory procedure of inverting a stoppered separatory funnel and opening the stopcock to relieve vapor pressure accumulated during vigorous shaking.
Separatory Funnel Stopper Removal
The procedural requirement of taking the stopper off the top of the separatory funnel while draining or allowing layers to settle to equalize internal and atmospheric pressure, preventing a vacuum from holding back the liquid.
Phenolphthalein Titration End Point
The point during neutralization titration with 0.10M NaOH at which the aqueous layer turns to a permanent faint pink color that does not fade within 20seconds.
Multiple Extraction Efficiency
The principle stating that performing multiple successive extractions using smaller volumes of solvent (e.g., two 50mL portions) recovers a greater total mass of solute than performing a single extraction with the entire volume (e.g., one 100mL portion).
Methylene Chloride (CH2Cl2)
A dense (1.33g/mL), volatile halogenated solvent with a low boiling point (40∘C) that causes a burning/tingling sensation upon skin contact and must always be disposed of in a halogenated waste container rather than down the sink.
Acetone
A non-halogenated organic solvent effective at dissolving organic residues when cleaning lab glassware; it must never be poured down the drain and must be placed into the dedicated non-halogenated waste container.
Crotonic Acid
An unsaturated carboxylic acid (C4H6O2) used in distribution experiments, characterized by a molar mass of 86.09g/mol and a melting point range of 70–72∘C.
Benzoic Acid
An aromatic carboxylic acid (C7H6O2) of moderate polarity with a molar mass of 122.12g/mol and a melting point range of 121–125∘C.
Solid-Liquid Extraction
A separation process in which a soluble target component is extracted from a solid matrix into a liquid solvent, commonly illustrated by brewing coffee/tea with hot water or washing soiled fabrics with detergent.
Table of Reagents (TOR)
A mandatory pre-lab notebook section recording all starting materials, products, solvents, and hood reagents needed for an experiment, including structures, molecular formulas, molecular weights, physical constants, and safety data.

Filter Flask (Suction Flask)
A thick-walled Erlenmeyer-style flask equipped with a short sidearm tubulation designed to connect to a vacuum source for vacuum filtration.

Büchner Funnel
A cylindrical porcelain funnel containing a flat perforated plate designed to support filter paper during vacuum filtration.

Three-Way Connecting Tube (Distillation Head)
A glass adapter containing three ground-glass joints, used in distillation setups to connect the distillation flask, condenser, and thermometer adapter.

Condenser
A straight glass cooling apparatus featuring an inner vapor tube surrounded by a water-cooling jacket with side hose barbs, used to condense vapors back to liquid.

Round-Bottom Flask
A spherical glass flask with a ground-glass neck designed to provide uniform heating or boiling under reduced pressure or atmospheric reflux conditions.

Neoprene Filter Adapters
Flexible, tapered rubber cones used to establish an airtight seal between a Büchner funnel stem and the neck of a vacuum filter flask.

Vacuum Takeoff Adapter
A curved glass connector with a ground-glass joint and side vacuum hose barb, positioned between a condenser and receiving flask during vacuum distillation.

Thermometer Adapter
An adapter with a ground-glass inner joint and a flexible top rubber/compression fitting designed to hold a thermometer securely at the distillation head.

Separatory Funnel
A pear-shaped piece of laboratory glassware equipped with a top ground-glass opening and a bottom stopcock, used to manipulate and partition immiscible liquid phases.

Ground Glass Stopper
A precision-ground solid glass stopper designed to fit into standardized ground-glass joint openings (such as on a separatory funnel or volumetric flask) to seal contents securely.