Electrical Module 6 Test

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/27

encourage image

There's no tags or description

Looks like no tags are added yet.

28 Terms

1
New cards

What is the maximum weight allowed by the NEC when ceiling fans are mounted directly to an approved, unmarked outlet box?

35 pounds

2
New cards

Square metal boxes are available in sizes of

4‑11/16"

3
New cards

A box installed under a roofed open porch is considered a

Damp location.

4
New cards

A single‑gang outlet box used for surface mounting on concrete or block construction is called a(n)

Handy box.

5
New cards

Octagon and round boxes are used mostly for

Wall‑mounted and ceiling‑mounted lighting fixtures.

6
New cards

How many conductors must be deducted for each strap‑mounted device in a device box?

2 conductors

7
New cards

When sizing outlet boxes, deduct ______ conductors for each switch.

2 conductors.

8
New cards

Each conductor originating outside the box and terminating inside counts as

1 conductor.

9
New cards

A conductor under 12" (300 mm) long running through a box counts as

1 conductor.

10
New cards

If there are four equipment grounding conductors in a box, you must deduct ______ conductor(s).

1 conductor

11
New cards

The capacity of an outlet box can be increased by using

Extension rings.

12
New cards

An extension ring is used to increase the

Depth of the box.

13
New cards

Box installations are covered in

NEC Sections 314.15 – 314.30

14
New cards

All boxes must be sized, installed, and supported to meet current

NEC requirements

15
New cards

Blank covers are used when boxes serve as

Junction boxes.

16
New cards

If the largest trade diameter of a raceway entering a pull box is 3", and it is a straight pull, the minimum box size is

24 inches

17
New cards

The depth of a pull box with conduit entering at right angles

Must be sufficient for proper installation of locknuts and bushings

18
New cards

A(n) ______ is an enclosure used to facilitate cable installation in long runs.

Pull box.

19
New cards

For a straight pull, the minimum box length must be at least ______ times the largest raceway diameter.

8 times.

20
New cards

The minimum length for a junction box with two 3" conduits and one 4" conduit entering each side (angle pull) is

30 inches total.

21
New cards

______ means constructed or protected so that exposure to beating rain will not allow water entry.

Raintight.

22
New cards

A box designed to withstand an internal explosion without causing an external one is

Explosion‑proof.

23
New cards

A box constructed so moisture will not enter under test conditions is

Watertight.

24
New cards

A box protected so that weather exposure will not interfere with operation is

Weatherproof

25
New cards

A(n) ______ is a metallic or nonmetallic box installed in a wiring system from which current is taken to supply a device.

Outlet box

26
New cards

A(n) ______ is an enclosure where raceways or cables enter and conductors may be spliced.

Junction box.

27
New cards

A(n) ______ is a device used to physically connect conduit or cable to an outlet box or enclosure.

Connector

28
New cards

What is the maximum distance between receptacles along the floor line in any wall space?

12 feet