1/109
Looks like no tags are added yet.
Location of heart
mediastinum between 2nd and 5th intercostal space
Heart relation to midline
Left of midline
Base and apex location
Base: Posterior surface toward right shoulder
Apex: Inferior pointing towards left hip
Pericardium
Double walled fibro sac encasing heart
Pericardium functions
protects
anchors
ensures heart does not over fill with blood
Parts of pericardium
fibrous pericardium
serous pericardium
parietal pericardium
visceral pericardium or epicardium
Fibrous pericardium
Superficial
Parietal pericardium
lines internal surface of pericardium
Visceral pericardium/epicardium
lines surface of heart
Serous pericardium
Deep double layer
Pericardial cavity
fluid filled cavity separating layers
Pericardium from superficial to deep
fibrous pericardium
parietal pericardium
pericardial cavity
epicardium
serous pericardium
Heart wall (superficial to deep)
Epicardium: visceral layer
Myocardium: cardiac muscle layer that is bulk of heart
Endocardium: endothelial layer of myocardium
Interatrial septum
Separates atria internally
coronary sulcus
atrioventricular groove (junctions between atrium and ventricle)
interventricular septum
Separates ventricles internally
Anterior and posterior interventricular sulci
Mark position of interventricular septum externally
Auricle function
Increases atrial volume
Muscles of anterior and posterior walls of atrium
anterior wall: pectinate muscles
posterior wall: smooth (no muscle)
Fossa ovalis
Depression in interatrial septum that is remnant of foramen ovale
Foramen ovale
Open flap between right and left atrium that closes after fetal life
How does blood enter right atria
superior vena cava
inferior vena cava
coronary sinus
How does blood enter left atria
4 great pulmonary veins
Walls of ventricle vs atrium
Ventricle walls are thicker
Ventricular wall components
Trabeculae muscles
papillary muscles (project to cavity)
Valves
AV valves (tri and bi cuspid)
AL valves (pulmonary sl and aortic sl)
heart valve function
Ensure unidirectional flow through heart
AV valve vs SL valve function
AV valves prevents backflow during contraction
SL valves prevent backflow during relaxation
Chordae tendineae
Anchor AV valve cusps to papillary muscles
coronary circulation
Blood supply to heart itself (shortest circulation)
coronary arteries location
arise from base of aorta and travel in coronary sulcus
Right coronary artery branches
Marginal artery: supplies right atrium and ventricle
Posterior interventricular artery: supplies posterior wall of ventricle
Left coronary artery branches
circumflex artery: supplies left atrium and posterior wall of left ventricle
anterior interventricular artery: supplies anterior ventricle walls and interventricular septum
Cardiac vein function
collect blood from capillary beds of myocardium
Coronary sinus function
Empties directly into right atrium
Cardiac veins making up coronary sinus (location)
Great cardiac vein (anterior interventricular sulcus)
Middle cardiac vein (posterior interventricular sulcus)
Small cardiac vein (right inferior margin)
Homeostatic imbalances of heart
Angina pectoris
Myocardial infraction
Angina pectoris
Thoracic pain caused by lack of blood delivery to myocardium (cells are weakened)
Myocardial infraction
Heart attack caused by prolonged coronary blockage
myocardial infraction cell repair
Dead cells are repaired with noncontractile scar tissue
Two conditions of weakend heart
incompetent valve
Valvular stenosis
Incompetent valve
Blood backflows so heart repumps same blood over and over
Valvular stenosis
Stiff flaps constrict opening so heart must work harder (generate more force) to pump blood
Right side of heart circulation
Pulmonary circuit
vessels carry deoxygenated blood to lungs to pick up O2 and return
short low pressure circulation
left side of heart circulation
Systemic circulation
oxygenated blood flows to all bodily tissues and returns deoxygenated
long and high pressure circulation
Cardiac muscle cell physical description
striated
short
fat
branched and interconnected
T tubules of cardiac muscle
Wider but less numerous
SR of cardiac muscle vs skeletal muscle
Less complex SR in cardiac muscle
Mitochondria of cardiac muscle
Large and numerous
intercalated discs
Junctions between cardiac cells that anchor them to one another
Functional syncytium
Myocardium acts as single unit during relaxation and contraction
myocytes
cardiac muscle cell
gap junctions and desmosomes function
gap junctions: electrically connect myocytes
desmosomes: ensure myocytes do not pull apart
two functional types of myocytes
autorhythmic: 1% of muscle cells that can spontaneously depolarize
contractile muscle cells: 99% of muscle cells responsible for pumping activity
Autorhythmic cell facts
pacemaker of heart
initiates depolarization/action potential of entire heart without nervous system
Autorhythmic cell refractory period
250ms
Action potential of pacemaker (autorhythmic cells) cellular steps
1) Pacemaker potential: K+ channels close and Na+ channels open to make membrane potential less negative
2) Depolarization: When threshold is reached action potential begins and Ca2+ channels open
3) Repolarization: Ca2+ channels close and K+ channels open to allow reestablishment of pacemaker potential voltage
Action potential of pacemaker (autorhythmic cells) graph
Pacemaker potential: resting potential -60mV to -40mV (never flat line)
Depolarization: -40mV to 10+mV
Repolarization: +10mV back to -60mV
Action potential of contractile muscle cells cellular activity
Depolarization occurs when Na+ channels open and positive feedback loop leads to more channels opening and less negative membrane potential
Plateau occurs when Ca2+ channels open after Na+ channels close but ca2+ diffuses slowly
Repolarization: Ca2+ channels close and K+ channels open to allow reestablishment of resting voltage
Action potential of contractile muscle cells graph
Depolarization: resting potential -90mV spikes 30mV
Plateau: Ca2+ holds membrane potential slightly above 0mV
Depolarization: return to -90mV
tension development
Occurs during plateau when influx of Ca2+ ions enter cells allowing for contraction
pacemaker potential
unstable resting potential of pacemaker/autorhythmic cells
Difference between depolarization phase of pacemaker vs contractile muscle cells
Rising depolarization of pacemaker is due to Ca2+ influx
Rising depolarization of contractile cells is Na+ influx
Sequence of excitation within gross heart anatomy
Sinoatrial (SA) node: generates impulse
Atrioventricular (AV) node: receives impulse (pause for 0.1s)
Atrioventricular (AV) bundle: connects atria to ventricles
Bundle branches (right and left): send impulse through interventricular septum
Subendocardial conducting network (Pinkinje fibers): depolarize contractile cells of ventricles
SA node composition
pacemaker/autorhythmic cells
SA and AV node locations
SA node: right atrial wall under entrance of superior vena cava
AV node: inferior interatrial septum, above tricuspid valve
SA node impulse generation rate
75impulses/min
AV node depolarization in absence of SA node
50depolarization/min
Result of defects in intrinsic conduction system
Arrythmias
Fibrillation
Tachycardia
Bradycardia
Arrythmias
Any irregular heart rhythm due to uncoordinated atrial and ventricular contraction
Fibrillation
fast irregular contractions that quiver instead of pump
tachycardia and bradycardia
tachycardia: Heart rate over 100bpm
bradycardia: heart rate under 60bpm
ANS relation to heart
Controls heart rate
Where do cardiac centers originate
medulla oblongata containing cardioacceleratory ceneter and cardioinhibitory center
Heart rate increase pathway
Cardioaccelerator center → sympathetic nervous system (thoracic spinal cord) → SA and AV nodes
Heart rate decrease pathway
Cardioinhibitory center → parasympathetic nervous system (vagus nerve) → SA and AV nodes
EKG (Electrocardiogram) function
reading of all action potentials generated by nodal and contractile cells at a given time
Three waves of EKG and fucntion
P wave: depolarization of SA node (atrial contraction)
QRS complex: depolarization of ventricles (ventricular contraction)
T wave: repolarization of ventricles (relaxation of ventricles)
Three waves of EKG time
P wave: 0.2s
QRS complex: 0.2s - 0.4s
T wave: 0.5s-0.6s
(0.4-0.5s is S-T segment
EKG intervals and segments
P-Q interval: start of atrial depolarization to start of ventricular depolarization
Q-T interval: start of ventricular depolarization to start of repolarization
S-T: segment: entire ventricular myocardium depolarized (cells in plateau)
EKG relation to sequence of excitation of heart
1) P wave is sinoatrial (SA) node activating atrial depolarization
2) Delay between P wave and QRS is due to 0.1s delay of AV node receiving impulse
3) QRS complex is ventricular depolarization starting at apex and atrial repolarization
4) S-T segment is plateau phase of ventricle
5) T wave is repolarization starting at apex
6) Complete repolarization ends T wave
Enlarged R wave indication
Enlarged Ventricles
Elevated or depressed S-T segment indication
cardiac ischemia - reduced oxygenated blood to heart
Prolonged Q-T interval indication
Repolarization abnormality that increases risk of ventricular arrythmia
Q wave indication
Myocardial infraction
First and second sound of heart
First sound: Closing of AV valves beginning systole
Second sound: Closing of SL valves beginning diastole
Heart murmurs
Abnormal heart sounds linked to valve problems
Parts of cardiac cycle
Systole: contraction
Diastole: relaxation
Time for cardiac cycle
0.8s
cardiac cycle time intervals
Atrial systole 0.1s
Ventricular systole 0.3s
Heart relaxation 0.4s
Blood flow during diastole and systole
Diastole: Atrial and ventricular filling (blood in)
Systole: Atrial and ventricular contraction (blood out)
Valves during diastole and systole
Diastole: AV valves open and SL valves closed
Systole: AV valves closed and SL valves open
cardiac cycle phases
1) ventricular filling
2) Atrial contraction
3) isovolumetric contraction
4) ventricular ejection
5) isovolumetric relaxation
ventricular filling Atrium, Ventricles, and valves
Atrium: relaxed
ventricles: relaxed
AV valves open
SL valves closed
ventricular filling blood flow
IVC and SVC → RA
Pulmonary veins → LA
Atria → ventricles
Atrial systole Atria, ventricles, Valves
Atria: contracted (depolarized)
Ventricles: relaxed
Valves: AV valves open, SL valves closed
Atrial systole blood flow
RA → RV
LA → LV
Atrial systole on EKG
P wave (Atrial depolarization)
EDV and ESV ventricular volume
EDV: max ventricular blood volume
ESV: Least ventricular blood volume
ventricular systole Atria, ventricles, pressure
Atria: relaxed and less pressure
Ventricles: contracted and more pressure