1/81
Comprehensive vocabulary flashcards covering Work Health and Safety (WHS) regulations, pre-operational checks, hazard controls, emergency procedures, and safe operation of Elevating Work Platforms (EWPs).
Hazard
A situation or thing that has the potential to harm a person.
Risk
The likelihood or possibility of a hazard occurring.
Duty of a Worker
The legal obligation of a worker to take care of yourself and take care of others.
WorkSafe Licence Penalties
The disciplinary actions WorkSafe can take if a worker fails to uphold duty of care, specifically to suspend or revoke your licence.
Key WHS Documents
Work Health and Safety documents that govern work practices, including Acts, regulations, standards, codes of practice, and standard operating procedures (SOP).
Employer Safety Requirements
Three mandatory duties an employer must provide: maintain a safe work environment, provide safe systems of work, and provide adequate facilities.
Post-Licence Employer Provisions
Two critical workplace supports an employer must provide to an operator after getting a licence: supervision and instruction.
Hazard Consultation Personnel
Four key parties to consult regarding site hazards: supervisors, Health and Safety Representatives (HSR/HCR), safety coordinators, and colleagues.
Timing of Control Measures
The requirement that safety control measures must be applied before work starts or as soon as a hazard becomes known.
Powerline Safe Clearance Distances
Specific clearance boundaries for electrical lines: 3Meters for up to 1302kV, 6Meters for 132–330kV, and 8Meters for +330QkV.
Electrical Spotter and Permit
Authorizations and specialized personnel required if work must be conducted closer to power lines than the standard clearance.
Visual Indicators for Powerlines
Physical markers used to make powerlines conspicuous, including tiger tails, marker balls, signs, and flags.
Powerline Contact Procedure
Emergency steps taken if an EWP contacts lines: warn others to stay away; attempt to break contact; stay in machine if safe; if forced to leave, jump clear without touching machine, land with both feet on ground and shuffle away; report incident; and have machine checked before reuse.
Wind Limit Protocol
The mandatory action to stop work and lower the platform if the wind speed exceeds rated operational limits.
Wind Information Sources
The two official places where an operator can find wind speed rating information: the data plate and the operator's manual.
Work Over Water Equipment
Special safety provisions required when operating over water, consisting of a life jacket and a rescue boat.
Communication Methods
Two-way radios and hand signals, chosen at the planning stage, inspected prior to starting, and requiring the operator to stop and clarify if an unclear signal is received.
Data Plate
A readable plate on the EWP that communicates the rated capacity (e.g., 250kg), operational standards, and emergency operating procedures.
Logbook Pre-Start Check
A mandatory review conducted during pre-start checks to confirm the machine's service history and check for any recorded faults or defects.
Defective / Out-of-Service Tag Removal
A safety tag that indicates damage (such as cracks, flaky paint, oil leaks, bent pins, or missing/loose bolts) and can only be removed once deemed safe by a competent person.
Pigstye Packing
Hardwood or steel packing arrangement used for ground stabilization, where the first layer must be placed at an angle of 90∘.
Live Load
The total combined weight of materials, tools, and people carried in the EWP platform.
Dead Load
The total weight of the EWP machine itself.
Wind Load
The maximum wind speed, measured in meters per second, that an elevated work platform can safely withstand during operation.
Dead Man Switch
A safety foot switch or control mechanism that acts as a lockout to prevent accidental movement of the EWP.
Ground Controls
Lower-level controls used for testing, maintenance, and bringing the boom to the ground during an emergency.
Raised EWP Travel Mode
The crawl or slow mode speed setting required whenever moving an EWP with the platform raised.
Tool Securing in EWP
The practice of securing tools to prevent them from jamming controls, blocking access/egress, or creating trip hazards.
Emergency Lowering Mechanisms
Backup mechanical systems, such as the hydraulic accumulator or manual bleed valve, used to lower the EWP if the motor turns off.
Crane and Rail Lifting Restrictions
Rules specifying that boom lifts cannot be used as a crane and loads cannot be attached to platform rails unless explicitly designed to do so.
EWP Shutdown Sequence
The six steps required to park and secure an EWP: lower safely, complete logbook, remove keys, secure tools/harness, ensure EWP is safe, and install boom locking pin/strap.
Trench Distance Rule
A safety requirement stating that an EWP must be set up at a distance from a trench equal to the trench's depth to prevent collapse.
Engineer's Report
A certified document consulted to confirm whether a concrete slab has the capacity to support the weight of an EWP.
Spirit Level
An instrument used by the operator to verify that the EWP is completely level before raising or operating.
Equipment Load Calculation
The mathematical calculation of remaining payload capacity: Max Load (230kg)−Personnel (80kg+90kg=170kg)=60kg available for equipment.
Operational Checks
Four critical post-start function tests performed before use: operational controls, brakes, ground controls, and steering.
Hazardous Surface Conditions
Five ground hazards that threaten EWP stability: trench covers, pit covers, backfilled ground, soft soils, and bitumen (bichement).
Exclusion Zone Breach Protocol
The required procedure when an unauthorized person enters the exclusion zone: stop work immediately, identify the person, have the spotter remove them / ask them to leave, lower to ground, and report the incident.
Hazard
A situation or thing that has the potential to harm a person.
Risk
The likelihood or possibility of a hazard occurring.
Worker Duty of Care
The legal obligation of a worker to take care of themselves and take care of others in the workplace.
WorkSafe Enforcement Action
The disciplinary action taken by the regulator to suspend or revoke a worker's licence if they fail to meet duty of care obligations.
Work Health and Safety (WHS) Primary Documents
Key regulatory frameworks governing workplace safety, comprising Acts, regulations, standards, codes of practice, and Standard Operating Procedures (SOPs).
Employer Safety Requirements
Core statutory employer obligations to maintain a safe work environment, provide safe systems of work, and provide adequate facilities.
Post-Licensing Employer Obligations
Mandatory ongoing support an employer must provide to a qualified worker, specifically supervision and instruction.
Hazard Consultation Personnel
Specific roles designated for consultation regarding workplace hazards, including supervisors, Health and Safety Representatives (HSR), safety coordinators, and colleagues.
Timing of Control Measures
The rule requiring that risk controls must be applied before work commences or as soon as a hazard becomes known.
Power Line Clearance Distances
Minimum safe approach limits for overhead electrical assets: 3m for voltages up to 132kV, 6m for voltages between 132kV and 330kV, and 8m for voltages exceeding 330kV.
Electrical Spotter and Permit
Mandatory control measures required if EWP work must be performed closer to power lines than the standard statutory clearance limits.
Power Line Visual Indicators
Warning devices used to increase the visibility of overhead electrical cables, including tiger tails, marker balls, signs, and flags.
Shuffle Technique (Power Line Contact)
An emergency egress method used if escaping an energized machine: jump clear without touching the chassis and ground simultaneously, land with both feet together, and shuffle at least 8m away.
Power Line Contact Emergency Procedure
The sequential protocol when contacting electrical lines: warn others to stay away, attempt to break contact, remain in the machine if safe, jump clear and shuffle away if forced to evacuate, report the incident, and have the machine inspected before reuse.
High Wind Operating Hazards
Risks introduced by elevated wind speeds, specifically falling objects and uncontrollable movement of the platform.
Wind Speed Information Sources
The two manufacturer-specified references for determining the maximum operational wind rating of an EWP: the data plate and the operator's manual.
Over-Water Safety Equipment
Specialized personal protective and rescue equipment mandatory when operating an EWP over water, specifically a life jacket and a dedicated rescue boat.
Pre-Movement EWP Checks
Environmental and load parameters to verify prior to driving or repositioning an EWP: the weight of the load, weather conditions, and adjacent buildings or structures.
Pre-Raising Platform Considerations
Critical safety checks required before elevating the EWP basket: access and egress paths, the safe work radius, and the weight and size of the load.
EWP Communication Methods
Agreed protocols established during the planning phase to coordinate operations, consisting of two-way radios and hand signals.
Unclear Communication Protocol
The safety directive requiring the EWP operator to halt operations immediately and clarify instructions whenever an ambiguous signal or transmission is received.
Data Plate
A permanent metal plate affixed to the EWP displaying technical specifications, standard operational limits, emergency operating procedures, and rated capacity (e.g., 250kg).
EWP Pre-Start Inspection
Daily physical inspections performed by the operator to verify safety prior to use, covering fluid levels, tire condition, tire pressure, boom, platform condition, steering teeth, data plate, and structural defects.
EWP Logbook Checks
A pre-operational documentation review verifying the service history of the machine and ensuring all previously recorded faults or defects have been rectified.
EWP Defect Indicators
Physical signs indicating structural compromise or mechanical failure, including cracks, flaky paint, oil leaks, bent pins, and loose or missing bolts.
Defective Tag Removal Rule
The regulatory requirement stipulating that an out-of-service or defect tag may only be removed once the machine is formally deemed safe by a competent person.
Pigsty Packing
A cribbing method utilizing hardwood packing or steel plates under outriggers where each alternating layer is oriented at a 90∘ angle to establish stable ground bearing.
Live Load
The variable weight supported by the platform, consisting of the combined weight of personnel, tools, and materials.
Dead Load
The static tare weight of the elevated work platform itself.
Wind Load
The lateral force exerted by the atmosphere against the EWP structure, rated by maximum permissible velocity in meters per second (m/s).
Dead Man Switch
A foot switch or safety interlock mechanism designed to lock out machine controls and prevent accidental boom or platform movement.
Ground Controls
The secondary control station situated at the base of the EWP, utilized for maintenance testing and emergency platform lowering.
Raised EWP Travel Speed
The restricted slow or crawl mode setting required whenever an EWP is driven while the boom or platform is in an elevated position.
EWP Tool Securing
The practice of tethering and securing equipment in the basket to prevent controls from jamming, keep access and egress clear, and eliminate trip and fall hazards.
Basket Tilting, Dipping, or Dropping Protocol
Emergency procedures to follow if the basket tilts, dips, or drops: stop work immediately, notify personnel on the ground, lower the platform, and inspect the machine.
Emergency Lowering Mechanisms
Auxiliary systems used to retrieve the platform if the main motor fails, specifically the hydraulic accumulator and manual bleed valve.
Crane and Rail Loading Restrictions
Operational rules prohibiting boom lifts from being used as cranes and forbidding loads from being suspended from basket guardrails unless explicitly rated and designed to do so.
EWP Shutdown Sequence
The standard procedure for decommissioning an EWP after use: lower safely, ensure the machine is safe/parked, secure tools and harness, remove keys, complete the logbook, and install the boom locking pin or strap.
Trench Setback Distance Rule
The stability guideline mandating that an EWP must be positioned away from an excavation edge at a distance at least equal to the depth of the trench.
Concrete Slab Weight Verification
The requirement to review a certified engineer's report to determine whether an elevated concrete slab can support the total weight of the machine and payload.
Hazardous Surface Conditions
Unstable ground features that threaten EWP equilibrium, including backfilled earth, soft soils, bitumen, trench covers, and pit covers.
EWP Operational Checks
Pre-work functional tests performed on active components, specifically verifying operational controls, brakes, steering, and ground controls.
Exclusion Zone Intrusion Protocol
The five-step procedure when an unauthorized person breaches the perimeter: stop work immediately, identify the person, direct the spotter to remove them or ask them to leave, lower the platform to ground, and report the incident.
Remaining Equipment Payload Calculation
The method of subtracting total personnel weight from rated capacity to find allowable tool payload: given a maximum load of 230kg and two workers weighing 80kg and 90kg (170kg total), the allowable equipment load is 230kg−170kg=60kg.