restrictive
Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most_________shall govern.
Section R102.1
minimum
The purpose of this code is to establish ________ requirements to safeguard the public safety, health and general welfare.
Section R101.3
IRC
Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of the IRC, the provisions of the ________ shall take precedence.
Section R102.4.2
satisfactory intent
An alternative material or method shall be approved where the proposed design is _______ and complies with _______of the provisions of the IRC.
Section R104.11
200 sq ft
Other than storm shelters, a permit is not required for one story detached accessory structures, provided that the floor area does not exceed _______ square feet
Section R 105.2
performance
Compliance with the specific ________ -based provisions of the International Codes shall be an alternative to the specific requirements of the IRC
Section R104.11
7 ft
Fences not over_______ feet high do not require permits
Section R105.2
required
A permit is not required for the replacement of branch circuit overcurrent devices(breakers) of the ________ capacity in the same location (within a panel)
Section R105.2
200 sq ft 30in
Decks not exceeding ______ square feet in area, that are not more than _______ inches above grade at any point, are not attached to a dwelling, do not require a permit.
Section R105.2
next working (to the building official)
Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the _______ _________ business day.
Section R105.2.1
180 (180 days also applies to extensions)
An application for a permit for any proposed work shall be deemed to have been abandoned ___________days after the date of filing.
Section R105.3.2
authorized
Before issuing a permit, the building official is __________ to examine or cause to be examined buildings, structures and sites for which an application has been filed.
Section R105.9
REVIEWED FOR CODE COMPLIANCE
Where the building official issues a permit, the construction documents shall be approved in writing or by a stamp that states ___________ _________ _________ ___________.
Section R106.3.1
complete occupancy
Final inspection shall be made after the permitted work is ____________ and prior to ____________.
Section R109.1.6
final
If located in a flood hazard area, the documentation of elevations required in Section R322.1.10 shall be submitted to the building official prior to the ______________ inspection
Section R109.1.6.1
Access (to)
That which enables a device, an appliance or equipment to be reached by ready access or by a means that first requires the removal or movement of a panel, door or similar obstruction.
Section R202
Attic, Habitable
A finished or unfinished habitable space within a attic
Section R202
120*F
Hot water is water at a temperature greater than ________*F
Section R202
load-bearing
A wall supporting any vertical load in addition to its own weight is a ___________-_____________ wall
Section R202
30 pounds per square foot
What is the minimum uniformly distributed live load for habitable attics and attics served with fixed stairs?
Table R301.5
7/16in 8ft
Wood structural panels with a thickness of not less than __________ inch and a span of not more than _________ feet shall be permitted for opening protection in windborne debris regions.
Section R301.2.1.2
D0, D1 and D2
The seismic provisions of the IRC apply to detached one- and two family dwellings in Seismic Design Categories _______________.
Section R301.2.2
3 ft
For dwellings with fire sprinkler systems, exterior walls with a fire separation distance less than __________ feet shall have not less than a 1 hour fire-resistance rating with exposure from the outside.
Table R302.1.(2)
2 hr fire-resistance rated
Where an automatic sprinkler system in accordance with Section P2904 is not provided, the common wall between townhouse units shall be not less than a _________-hour_________-__________-__________wall assembly.
Section R302.2.2
4 ft 4 ft
For townhouse separation, a parapet is not required where the roof sheathing is fire-retardant-treated wood for a distance of ___________feet on each side of the wall or walls and there are no penetrations in the roof within ________feet of the common walls.
Section R 302.2.4
1 hr
Dwelling units in two-family dwellings shall be separated from each other by wall and floor assemblies having not less than a ___________- hour fire-resistance rating
Section R302.3
sleeping purposes
Opening from a private garage directly into a room used for ___________ _________ shall not be permitted.
Section R302.5.1
self-latching automatic-closing device
Doors between the garage and residence shall be ___________ ____________ and shall be equipped with a self-closing or ___________-__________ ____________.
Section R302.5.1
1/2in
Garages shall be separated from residences and attics by not less than ____________-inch gypsum board or equivalent applied to the garage side.
Table R302.6
1/2
Enclosed space under stairs that is accessed by a door or access panel shall have walls, under-stairs surface and any soffits protected on the enclosed side with__________- inch gypsum board.
Section R302.7
200
Wall and ceiling finishes shall have a flame spread index of not greater than ______________.
Section R302.9.1
stories
In combustible construction, fireblocking shall be provided to cut off both vertical and horizontal concealed draft openings and to form an effective fire barrier between ___________, and between a top story and the roof space.
Section R302.11
16 in
Unsafe fiberglass batt insulation used as fireblocking shall fill the entire cross section of the wall cavity to a height of not less than _________ inches measured vertically.
Section R302.11.1.2
1,000 sq ft
In combustible construction where there is usable space both above and below the concealed space of a floor-ceiling assembly, draftstops shall be installed so that the area of the concealed space does not exceed _________ square feet.
Section R302.12
1/2in 5/8in
Floor assemblies that are not required elsewhere in this code to be fire- resistance related, shall be provided with a __________- inch gypsum wallboard membrane, _________- inch wood structural panel membrane, or equivalent on the underside of the floor framing member.
Section R302.13
4 %
For natural ventilation for habitable rooms, the openable area to the outdoors shall be not less than _______ percent of the floor area being ventilated.
Section R303.1
8 %
Habitable rooms shall have an aggregate glazing area of not less than ______ percent of the floor area of such rooms.
Section R303.1
3 sq ft
Bathrooms, water closet compartments and other similar rooms shall be provided with aggregate glazing area in windows of not less than ______ square feet, one- half of which must be openable
Section R303.3
10 ft
Mechanical and gravity outdoor air intake openings shall be located not less than __________ feet from any hazardous or noxious contaminant, such as vents, chimney's, plumbing vents, streets, alleys, parking lots and loading docks.
Section R303.5.1
60 *F 68 *F
Where the winter design temperature in Table R301.2 is below ____________*F every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of not less than ____________*F
Section R303.10
70 sq ft
Habitable rooms shall have a floor are of not less than _______ square feet.
Section R304.1
7 ft
Habitable rooms shall be not less than ______ feet in any horizontal dimension.
Section R 304.2
7 ft
Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than _________ feet.
Section 305.1
6 ft 8 in
Bathrooms, toilet rooms and laundry rooms shall have a minimum ceiling height of __________ feet _________ inches.
R 305. 1
50 %
For rooms with sloped ceilings, not less than _______ percent of the required floor area shall have a ceiling height of not less than 7 feet.
Section R305.1
6 ft 8 In
Portions of basements that do not contain habitable space or hallways shall have a ceiling height of not less than _________ feet ___________ inches.
Section R 305.1.1
bathtub shower
Every dwelling unit shall be provided with a water closet, lavatory, and a __________ or ___________.
Section 306.1
sink
Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be provided with a _____________.
Section R 306. 2
hazardous location
Glazing in fixed and operable panels of swinging, sliding and bifold doors shall be considered to be a ___________ _____________.
Section R308.4.1
9 sq ft 18 in 36in
Glazing in an individual fixed or operable panel requires safety glazing if the pane is larger than ___________ square feet with a bottom edge less than____________ inches above the floor and a edge greater than _____________inches above the floor and a walking surface is within 36 inches of the glazing, measure horizontally.
Section R308.4.3
36 in
Glazing where the bottom exposed edge of the glazing is less than _____________ inches above the plane of the adjacent walking surface of stairways, landing between flights of stairs and ramps shall be safety glazing.
Section R308.4.6
36in 60in
Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than ________ inches above the landing and within a __________ inch horizontal arc less than 180 degrees from the bottom tread nosing shall be safety glazing.
Section 308.4.7
noncombustible
Garage floor surfaces shall be of approved ______________ material.
Section 309.1
two (2)
Carports shall be open on not less than _____________ sides.
Section 309.2
emergency escape rescue opening
Basements, habitable attics and every sleeping room shall have not less than one operable _____________ ____________ and ______________ ________________.
Section R310.1
44 in
Emergency escape and rescue openings shall have the bottom of the clear opening not greater than ______________ inches above the floor.
Section R310.2.3
5.7 sq ft
Emergency escape and rescue openings shall have a net clear opening of not less than _________ square feet.
Section R310.2.1
24 in 20 in
For emergency escape and rescue openings, the minimum net clear opening height dimension shall be ________ inches. The minimum net clear opening width dimension shall be ________ inches.
Section R310.2.2
9 sq ft 36in
The horizontal area of the area well serving an emergency escape and rescue opening shall be not less than _________ square feet with a horizontal projection and width of not less than _________ inches.
Section R310.4.1
44 in
Area wells with a vertical depth greater than _________ inches shall be equipped with an approved, permanently affixed ladder or steps.
Section R310.4.2
drainage
Area wells serving emergency escape and rescue opening shall be designed for proper___________.
Section R310.4.3
32 in
Not less than one egress door shall be provided for each dwelling unit. The egress door shall be side-hinged, and shall provide a clear width of not less than __________inches.
Section R311.2
36 in
There shall be a landing or floor on each side of each exterior door. Landings shall have a dimension of not less than _________ inches measured in the direction of travel.
Section R311.3
7 3/4 in
The landing or floor on the exterior side of the required egress floor shall be not more than ____________ inches below the top of the threshold provided that the door does not swing over the landing or floor.
Section R311.3.1
3 ft
The width of a hallway shall be not less than ______ feet.
Section R311.6
31 1/2in
The clear width of stairways at and below the handrail height, including treads and landing, shall be not less than _______ inches where a handrail is installed on one side.
Section R311.7.1
12 ft 7 in
A flight of stairs shall not have a vertical rise greater than __________ feet _________ inches between floor levels or landings.
Section R311.7.3
landing
There shall be a floor or ____________ at top and bottom of each stairway.
Section R311.7.6
36 in
Where the stairway has a straight run, the depth in the direction of travel shall be not less than __________ inches.
Section R311.7.6
1 unit 12 units
Ramps serving the egress door required by Section R 311.2 shall have a slope of not more than ___________ unit vertical in ___________units horizontal (8.3 percent slope).
Section R311.8.1
36 in
Stairways shall be not less than ________ inches in clear width at all points above the permitted handrail height and below the required headroom height.
Section R311.7.1
Yes
Is plastic composite material permitted for use as exterior stair treads?
Section R311.7.5.4
7 3/4 in
The riser height shall be not more than __________ inches.
Section R311.7.5.1
24 in
A clearance of at least ___________ inches shall be provided at the front of a shower opening.
Figure R 307.1
6 ft
Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than __________ feet above the floor.
Section R 307.2
10 in
The tread depth shall be not less than ___________ inches.
Section R311.7.5.2
3/8 in
The greatest riser height within any flight of stairs shall not exceed the smallest by more than __________ inch.
Section R311.7.5.1
3/8 in
The greatest tread depth within any flight of stairs shall not exceed the smallest by more than _________ inches.
Section R311.7.5.2
3/4 inch 1 1/4 in
A nosing projection not less than _________ inch and not more than __________ inches shall be provided on stairways.
Section R311.7.5.3
6 ft 8 in
The headroom in stairways shall be not less than _____________feet_____________ inches measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway.
Section R 311.7.2
26 in 24 1/2in
On spiral stairways, the minimum width shall be __________inches and the walkline radius shall be not greater than _________ inches.
Section R311.7.10.1
9 1/2 in 6ft 6in
On spiral stairways, treads shall be identical and the rise shall be not more than ___________inches. Headroom shall be not less than____________ feet ____________ inches.
Section R311.7.10.1
34 in 38 in
Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than ______________ inches and not more than ____________ inches.
Section R311.7.8.1
1 1/2 inch
Handrails adjacent to a wall shall have a space of not less than _________ inches between the wall and the handrails.
Section R311.7.8.3
1 1/4 in 2 in
Type I handrails with a circular cross section shall have an outside diameter of not less than ________ inches and not greater than _________ inches.
R 311.7.8.5
30 in 36 in
Guards shall be provided for those portions of open-sided walking surfaces, including floors, stairs, ramps and landings that are located more than __________inches above the floor or grade below. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than ___________inches in height.
Section R312.1 R312.1.1 R312.1.2
4 in
Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere_________ inches in diameter.
Section R 312.1.3
additions alterations
An automatic sprinkler system shall not be required where ______________ or ______________ are made to existing townhouses that do not have an automatic sprinkler system installed.
Section R 313.1
3 ft
Smoke alarms shall be installed not less than __________feet horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a required smoke alarm.
Section R 314.3
6 ft
Photoelectric smoke alarms shall not be installed less than __________ feet horizontally from a permanently installed cooking appliance.
Section R 314.3.1
battery
Smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and, where primary power is interrupted, shall receive power from a ____________.
Section R 314.6
listed wireless
Physical interconnection of smoke alarms shall not be required where ___________ ____________ alarms are installed.
Section R 314.4
sleeping area bedrooms
Carbon monoxide alarms shall be installed outside of each separate _____________ _____________ in the immediate vicinity of the _________________.
Section R315.3
75 450
Foam plastic insulation installed at 4 inches in thickness or less shall have a flame spread index of not more than ______________ and a smoke-developed index of not more than _________________.
Section R 316.3.1
thermal barrier 1/2 in
Foam plastic shall be separated from the interior of a building by an approved _________________ ______________of not less than _____________- inch gypsum wallboard.
Section R 316.4
repairs maintenance
A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purposes of ___________ or ___________.
Section R 316.5.3
6in
In areas where the probability of termite infestation is "very heavy" the clearance between foam plastics installed above grade and exposed earth shall be not less than __________ inches.
Section R318.4
1 hr
Dwelling units in two-family dwellings shall be separated from each other by wall and floor assembles having not less than a __________ - hour fire-resistance rating.
Section R 302.3
decay
Protection of wood and wood-based products from _______________ shall be provided in specified locations by the use of naturally durable wood or wood that is preservative-treated.
Section R317.1
4 in 1/2 (0.5) in
Address numbers shall be not less than _____________ inches in height with a stroke width of not less than ________________ inch.
Section R 319.1