1
New cards

restrictive

Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most_________shall govern.

Section R102.1

2
New cards

minimum

The purpose of this code is to establish ________ requirements to safeguard the public safety, health and general welfare.

Section R101.3

3
New cards

IRC

Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of the IRC, the provisions of the ________ shall take precedence.

Section R102.4.2

4
New cards

satisfactory intent

An alternative material or method shall be approved where the proposed design is _______ and complies with _______of the provisions of the IRC.

Section R104.11

5
New cards

200 sq ft

Other than storm shelters, a permit is not required for one story detached accessory structures, provided that the floor area does not exceed _______ square feet

Section R 105.2

6
New cards

performance

Compliance with the specific ________ -based provisions of the International Codes shall be an alternative to the specific requirements of the IRC

Section R104.11

7
New cards

7 ft

Fences not over_______ feet high do not require permits

Section R105.2

8
New cards

required

A permit is not required for the replacement of branch circuit overcurrent devices(breakers) of the ________ capacity in the same location (within a panel)

Section R105.2

9
New cards

200 sq ft 30in

Decks not exceeding ______ square feet in area, that are not more than _______ inches above grade at any point, are not attached to a dwelling, do not require a permit.

Section R105.2

10
New cards

next working (to the building official)

Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the _______ _________ business day.

Section R105.2.1

11
New cards

180 (180 days also applies to extensions)

An application for a permit for any proposed work shall be deemed to have been abandoned ___________days after the date of filing.

Section R105.3.2

12
New cards

authorized

Before issuing a permit, the building official is __________ to examine or cause to be examined buildings, structures and sites for which an application has been filed.

Section R105.9

13
New cards

REVIEWED FOR CODE COMPLIANCE

Where the building official issues a permit, the construction documents shall be approved in writing or by a stamp that states ___________ _________ _________ ___________.

Section R106.3.1

14
New cards

complete occupancy

Final inspection shall be made after the permitted work is ____________ and prior to ____________.

Section R109.1.6

15
New cards

final

If located in a flood hazard area, the documentation of elevations required in Section R322.1.10 shall be submitted to the building official prior to the ______________ inspection

Section R109.1.6.1

16
New cards

Access (to)

That which enables a device, an appliance or equipment to be reached by ready access or by a means that first requires the removal or movement of a panel, door or similar obstruction.

Section R202

17
New cards

Attic, Habitable

A finished or unfinished habitable space within a attic

Section R202

18
New cards

120*F

Hot water is water at a temperature greater than ________*F

Section R202

19
New cards

load-bearing

A wall supporting any vertical load in addition to its own weight is a ___________-_____________ wall

Section R202

20
New cards

30 pounds per square foot

What is the minimum uniformly distributed live load for habitable attics and attics served with fixed stairs?

Table R301.5

21
New cards

7/16in 8ft

Wood structural panels with a thickness of not less than __________ inch and a span of not more than _________ feet shall be permitted for opening protection in windborne debris regions.

Section R301.2.1.2

22
New cards

D0, D1 and D2

The seismic provisions of the IRC apply to detached one- and two family dwellings in Seismic Design Categories _______________.

Section R301.2.2

23
New cards

3 ft

For dwellings with fire sprinkler systems, exterior walls with a fire separation distance less than __________ feet shall have not less than a 1 hour fire-resistance rating with exposure from the outside.

Table R302.1.(2)

24
New cards

2 hr fire-resistance rated

Where an automatic sprinkler system in accordance with Section P2904 is not provided, the common wall between townhouse units shall be not less than a _________-hour_________-__________-__________wall assembly.

Section R302.2.2

25
New cards

4 ft 4 ft

For townhouse separation, a parapet is not required where the roof sheathing is fire-retardant-treated wood for a distance of ___________feet on each side of the wall or walls and there are no penetrations in the roof within ________feet of the common walls.

Section R 302.2.4

26
New cards

1 hr

Dwelling units in two-family dwellings shall be separated from each other by wall and floor assemblies having not less than a ___________- hour fire-resistance rating

Section R302.3

27
New cards

sleeping purposes

Opening from a private garage directly into a room used for ___________ _________ shall not be permitted.

Section R302.5.1

28
New cards

self-latching automatic-closing device

Doors between the garage and residence shall be ___________ ____________ and shall be equipped with a self-closing or ___________-__________ ____________.

Section R302.5.1

29
New cards

1/2in

Garages shall be separated from residences and attics by not less than ____________-inch gypsum board or equivalent applied to the garage side.

Table R302.6

30
New cards

1/2

Enclosed space under stairs that is accessed by a door or access panel shall have walls, under-stairs surface and any soffits protected on the enclosed side with__________- inch gypsum board.

Section R302.7

31
New cards

200

Wall and ceiling finishes shall have a flame spread index of not greater than ______________.

Section R302.9.1

32
New cards

stories

In combustible construction, fireblocking shall be provided to cut off both vertical and horizontal concealed draft openings and to form an effective fire barrier between ___________, and between a top story and the roof space.

Section R302.11

33
New cards

16 in

Unsafe fiberglass batt insulation used as fireblocking shall fill the entire cross section of the wall cavity to a height of not less than _________ inches measured vertically.

Section R302.11.1.2

34
New cards

1,000 sq ft

In combustible construction where there is usable space both above and below the concealed space of a floor-ceiling assembly, draftstops shall be installed so that the area of the concealed space does not exceed _________ square feet.

Section R302.12

35
New cards

1/2in 5/8in

Floor assemblies that are not required elsewhere in this code to be fire- resistance related, shall be provided with a __________- inch gypsum wallboard membrane, _________- inch wood structural panel membrane, or equivalent on the underside of the floor framing member.

Section R302.13

36
New cards

4 %

For natural ventilation for habitable rooms, the openable area to the outdoors shall be not less than _______ percent of the floor area being ventilated.

Section R303.1

37
New cards

8 %

Habitable rooms shall have an aggregate glazing area of not less than ______ percent of the floor area of such rooms.

Section R303.1

38
New cards

3 sq ft

Bathrooms, water closet compartments and other similar rooms shall be provided with aggregate glazing area in windows of not less than ______ square feet, one- half of which must be openable

Section R303.3

39
New cards

10 ft

Mechanical and gravity outdoor air intake openings shall be located not less than __________ feet from any hazardous or noxious contaminant, such as vents, chimney's, plumbing vents, streets, alleys, parking lots and loading docks.

Section R303.5.1

40
New cards

60 *F 68 *F

Where the winter design temperature in Table R301.2 is below ____________*F every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of not less than ____________*F

Section R303.10

41
New cards

70 sq ft

Habitable rooms shall have a floor are of not less than _______ square feet.

Section R304.1

42
New cards

7 ft

Habitable rooms shall be not less than ______ feet in any horizontal dimension.

Section R 304.2

43
New cards

7 ft

Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than _________ feet.

Section 305.1

44
New cards

6 ft 8 in

Bathrooms, toilet rooms and laundry rooms shall have a minimum ceiling height of __________ feet _________ inches.

R 305. 1

45
New cards

50 %

For rooms with sloped ceilings, not less than _______ percent of the required floor area shall have a ceiling height of not less than 7 feet.

Section R305.1

46
New cards

6 ft 8 In

Portions of basements that do not contain habitable space or hallways shall have a ceiling height of not less than _________ feet ___________ inches.

Section R 305.1.1

47
New cards

bathtub shower

Every dwelling unit shall be provided with a water closet, lavatory, and a __________ or ___________.

Section 306.1

48
New cards

sink

Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be provided with a _____________.

Section R 306. 2

49
New cards

hazardous location

Glazing in fixed and operable panels of swinging, sliding and bifold doors shall be considered to be a ___________ _____________.

Section R308.4.1

50
New cards

9 sq ft 18 in 36in

Glazing in an individual fixed or operable panel requires safety glazing if the pane is larger than ___________ square feet with a bottom edge less than____________ inches above the floor and a edge greater than _____________inches above the floor and a walking surface is within 36 inches of the glazing, measure horizontally.

Section R308.4.3

51
New cards

36 in

Glazing where the bottom exposed edge of the glazing is less than _____________ inches above the plane of the adjacent walking surface of stairways, landing between flights of stairs and ramps shall be safety glazing.

Section R308.4.6

52
New cards

36in 60in

Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than ________ inches above the landing and within a __________ inch horizontal arc less than 180 degrees from the bottom tread nosing shall be safety glazing.

Section 308.4.7

53
New cards

noncombustible

Garage floor surfaces shall be of approved ______________ material.

Section 309.1

54
New cards

two (2)

Carports shall be open on not less than _____________ sides.

Section 309.2

55
New cards

emergency escape rescue opening

Basements, habitable attics and every sleeping room shall have not less than one operable _____________ ____________ and ______________ ________________.

Section R310.1

56
New cards

44 in

Emergency escape and rescue openings shall have the bottom of the clear opening not greater than ______________ inches above the floor.

Section R310.2.3

57
New cards

5.7 sq ft

Emergency escape and rescue openings shall have a net clear opening of not less than _________ square feet.

Section R310.2.1

58
New cards

24 in 20 in

For emergency escape and rescue openings, the minimum net clear opening height dimension shall be ________ inches. The minimum net clear opening width dimension shall be ________ inches.

Section R310.2.2

59
New cards

9 sq ft 36in

The horizontal area of the area well serving an emergency escape and rescue opening shall be not less than _________ square feet with a horizontal projection and width of not less than _________ inches.

Section R310.4.1

60
New cards

44 in

Area wells with a vertical depth greater than _________ inches shall be equipped with an approved, permanently affixed ladder or steps.

Section R310.4.2

61
New cards

drainage

Area wells serving emergency escape and rescue opening shall be designed for proper___________.

Section R310.4.3

62
New cards

32 in

Not less than one egress door shall be provided for each dwelling unit. The egress door shall be side-hinged, and shall provide a clear width of not less than __________inches.

Section R311.2

63
New cards

36 in

There shall be a landing or floor on each side of each exterior door. Landings shall have a dimension of not less than _________ inches measured in the direction of travel.

Section R311.3

64
New cards

7 3/4 in

The landing or floor on the exterior side of the required egress floor shall be not more than ____________ inches below the top of the threshold provided that the door does not swing over the landing or floor.

Section R311.3.1

65
New cards

3 ft

The width of a hallway shall be not less than ______ feet.

Section R311.6

66
New cards

31 1/2in

The clear width of stairways at and below the handrail height, including treads and landing, shall be not less than _______ inches where a handrail is installed on one side.

Section R311.7.1

67
New cards

12 ft 7 in

A flight of stairs shall not have a vertical rise greater than __________ feet _________ inches between floor levels or landings.

Section R311.7.3

68
New cards

landing

There shall be a floor or ____________ at top and bottom of each stairway.

Section R311.7.6

69
New cards

36 in

Where the stairway has a straight run, the depth in the direction of travel shall be not less than __________ inches.

Section R311.7.6

70
New cards

1 unit 12 units

Ramps serving the egress door required by Section R 311.2 shall have a slope of not more than ___________ unit vertical in ___________units horizontal (8.3 percent slope).

Section R311.8.1

71
New cards

36 in

Stairways shall be not less than ________ inches in clear width at all points above the permitted handrail height and below the required headroom height.

Section R311.7.1

72
New cards

Yes

Is plastic composite material permitted for use as exterior stair treads?

Section R311.7.5.4

73
New cards

7 3/4 in

The riser height shall be not more than __________ inches.

Section R311.7.5.1

74
New cards

24 in

A clearance of at least ___________ inches shall be provided at the front of a shower opening.

Figure R 307.1

75
New cards

6 ft

Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than __________ feet above the floor.

Section R 307.2

76
New cards

10 in

The tread depth shall be not less than ___________ inches.

Section R311.7.5.2

77
New cards

3/8 in

The greatest riser height within any flight of stairs shall not exceed the smallest by more than __________ inch.

Section R311.7.5.1

78
New cards

3/8 in

The greatest tread depth within any flight of stairs shall not exceed the smallest by more than _________ inches.

Section R311.7.5.2

79
New cards

3/4 inch 1 1/4 in

A nosing projection not less than _________ inch and not more than __________ inches shall be provided on stairways.

Section R311.7.5.3

80
New cards

6 ft 8 in

The headroom in stairways shall be not less than _____________feet_____________ inches measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway.

Section R 311.7.2

81
New cards

26 in 24 1/2in

On spiral stairways, the minimum width shall be __________inches and the walkline radius shall be not greater than _________ inches.

Section R311.7.10.1

82
New cards

9 1/2 in 6ft 6in

On spiral stairways, treads shall be identical and the rise shall be not more than ___________inches. Headroom shall be not less than____________ feet ____________ inches.

Section R311.7.10.1

83
New cards

34 in 38 in

Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than ______________ inches and not more than ____________ inches.

Section R311.7.8.1

84
New cards

1 1/2 inch

Handrails adjacent to a wall shall have a space of not less than _________ inches between the wall and the handrails.

Section R311.7.8.3

85
New cards

1 1/4 in 2 in

Type I handrails with a circular cross section shall have an outside diameter of not less than ________ inches and not greater than _________ inches.

R 311.7.8.5

86
New cards

30 in 36 in

Guards shall be provided for those portions of open-sided walking surfaces, including floors, stairs, ramps and landings that are located more than __________inches above the floor or grade below. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than ___________inches in height.

Section R312.1 R312.1.1 R312.1.2

87
New cards

4 in

Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere_________ inches in diameter.

Section R 312.1.3

88
New cards

additions alterations

An automatic sprinkler system shall not be required where ______________ or ______________ are made to existing townhouses that do not have an automatic sprinkler system installed.

Section R 313.1

89
New cards

3 ft

Smoke alarms shall be installed not less than __________feet horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a required smoke alarm.

Section R 314.3

90
New cards

6 ft

Photoelectric smoke alarms shall not be installed less than __________ feet horizontally from a permanently installed cooking appliance.

Section R 314.3.1

91
New cards

battery

Smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and, where primary power is interrupted, shall receive power from a ____________.

Section R 314.6

92
New cards

listed wireless

Physical interconnection of smoke alarms shall not be required where ___________ ____________ alarms are installed.

Section R 314.4

93
New cards

sleeping area bedrooms

Carbon monoxide alarms shall be installed outside of each separate _____________ _____________ in the immediate vicinity of the _________________.

Section R315.3

94
New cards

75 450

Foam plastic insulation installed at 4 inches in thickness or less shall have a flame spread index of not more than ______________ and a smoke-developed index of not more than _________________.

Section R 316.3.1

95
New cards

thermal barrier 1/2 in

Foam plastic shall be separated from the interior of a building by an approved _________________ ______________of not less than _____________- inch gypsum wallboard.

Section R 316.4

96
New cards

repairs maintenance

A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purposes of ___________ or ___________.

Section R 316.5.3

97
New cards

6in

In areas where the probability of termite infestation is "very heavy" the clearance between foam plastics installed above grade and exposed earth shall be not less than __________ inches.

Section R318.4

98
New cards

1 hr

Dwelling units in two-family dwellings shall be separated from each other by wall and floor assembles having not less than a __________ - hour fire-resistance rating.

Section R 302.3

99
New cards

decay

Protection of wood and wood-based products from _______________ shall be provided in specified locations by the use of naturally durable wood or wood that is preservative-treated.

Section R317.1

100
New cards

4 in 1/2 (0.5) in

Address numbers shall be not less than _____________ inches in height with a stroke width of not less than ________________ inch.

Section R 319.1