V1 and V2
Septal view of the heart
V3 and V4
Anterior view of the heart
V5 and V6
Lateral view of the heart
Lead I
lateral view
lead II and III
inferior view
aVL
lateral view
aVF
inferior view
Standard limb leads
Bipolar
Leads I, II and III
Form Einhoven’s triangle
Augmented limb leads
Unipolar
aVR, aVL and aVF
Chest leads
V1-6
unipolar
Methods for calculating HR
R-R interval —> for regular rhythm
QRS complexes —> for irregular rhythm
R-R interval method
count number of large squares within one R-R interval
divide 300 by this number
QRS complex method
count number of QRS complexes in 10 secs
multiply by 6
Normal cardiac axis
represents the overall direction of electrical spread within the heart
In a normal person it is expected to lie between -30 (aVL) and 90 (aVF) degrees
positive deflection in lead I and II - indicates normal cardiac axis
(most positive in lead II - most closely aligned to overall electrical activity of the heart)
negative reflection in AVR (looks at heart in opposite direction)
Right axis deviation
depolarisation distorted to the right (90 to 180 degrees)
most commonly seen in RV hypertrophy eg. PHTN
or normal finding in tall individuals
lead I negative deflection and lead III more positive
Left axis deviation
depolarisation distorted to the left (-30 to -90)
normally due to LVH or conduction abnormalities
lead I = positive
lead II and III = negative deflection
Determining the cardiac axis
estimate using lead I and aVF
Lead I and aVF positive
normal cardiac axis (0 to 90 degrees)
lead I positive aVF negative
left axis deviation
lead I negative aVF positive
right axis deviation
lead I and aVF negative
extreme axis deviation
‘northwest axis’
atrial flutter
sawtooth baseline
atrial fibrillation
chaotic baseline
PR interval
should be between 120 and 200ms
prolonged PR interval suggests presence of AV delay/AV block
shortened PR suggests accessory pathway
Wolf-parkinson-white syndrome (WPW)
an accessory pathway leads to stimulation of the ventricles
allows electrical impulses to bypass the AV node
results in premature excitation of the proximal ventricles
coupled with normal conduction results in double excitation of the ventricles
shortened PR interval, widened QRS, delta wave
QRS complexes
normal <0.12s
broad complex = ventricular ectopic, BBB
Bundle branch blocks
unaffected ventricle contracts first
then electrical impulses move through the myocardium to the other side
results in slow and delayed depolarisation of the affected ventricle
loss in ventricle synchrony
therefore broader QRS
Right BBB
septal depolarisation from left to right
V1 - tall often notched R wave (rabbit ear pattern)
V6 - wide S wave
Left BBB
septal depolarisation right to left
V1 - deep S wave with little to no R wave
V6 - broad notched M-shaped R wave
distorted ST segment
ST segment
should be an isoelectric line
abnormalities indicate ischaemia or infarction
STEMI
significant when ST elevation >1mm in 2 or more contiguous limb leads
or >2mm in 2 or more chest leads
caused by acute full thickness MI
NSTEMI
ST depression
significant when equal to or more than 0.5mm in 2 or more continuous leads
ischaemia without complete artery blockage
can also see ST depression as a mirror image opposite territory with ST elevation
inferior wall
leads II, III and aVF
lateral wall
leads I, aVL, V5 and V6
anterior and septal wall
leads V1-4
Posterior wall
not directly seen on a standard 12 lead
requires additional leads V7, V8 and V9
Tall T waves
indicate hyperkalaemia or hyper acute STEMI
T wave inversion
normal variation (aVR, V1, III, V2 and V3)
new T wave inversion should be considered abnormal
non specific sign in pathological illness or specific for MI or myocarditis
U wave
not a common finding
>0.5mm deflection after the T wave
may indicate electrolyte abnormalities, hypothermia and anti-arrhythmia therapy
Things to think about when looking at ECG
rate
rhythm
axis
intervals
waveform
morphology
ST segments
ECG artifacts
muscle tremor (typically seen in limb leads not chest)
wandering baseline (breathing or poor electrode contact)
electrical interference (fuzzy baseline)