208 Terms

1
New cards

equipment and other soiled inanimate objects, called ____ will serve as reservoirs, particularly if they contain blood, urine, or other body fluids.

FOMITES

2
New cards

The host ingests a contaminated substance eg. food, water specimen

vehicle

3
New cards

Host INHALES DRIED AEROSOLS

Host INHALES AEROSOL DROPLETS

Airborne

Droplets

4
New cards

Methos to break the chain of infection

Hand sanitizing ang adhering to standard precautions

5
New cards

In clinical laboratory the most direct contact with a source of infection is through

Contact with patient samples

6
New cards

HICPAC

Health Infection Control Practices Advisory Committee

7
New cards

Combined the major guidelines of UP and BSI called Standard Precautions

CDC and HICPAC Health Infection Control Practices Advisory Committee

8
New cards

Delayed hypersensitivity reactions resembling posion ivy that appear 24 to 48 hours after exposure

Allergy to latex gloves

9
New cards

When specimens are received in containers contaminated exteriors, the exterior should

must be disinfected or if necessary, a new specimen may be requested

10
New cards

Sodium hypochlorite dilutions stored in PLASTIC BOTTLES are effective for

1 month if protected from light

11
New cards

EMPTY URINE CONTAINERS can be discarded in

NONBIOLOGICALLY hazardous waste

12
New cards

Requires that all employees have a ___ about all chemical hazards present in their workplace

RIGHT TO KNOW

13
New cards

All electrical equipment must be grounded with

THREE-PRONGED PLUGS

14
New cards

requires that all health care facilities post evacuation routes and detailed plans to follow in the event of fire

The Joint Commission TJC

15
New cards

Organic peroxides are under

flame sign and exploding bombs

16
New cards

Overall process of guaranteeing quality patient care and it is regulated through the TOTAL TESTING SYSTEM.

Quality Management

17
New cards

All of the laboratory’s policies, process, procedures, and resources needed to achieve quality testing. includes not only test ing controls, referred to as quality control (QC), but also encompasses preexamination (preanalytical) variables (e.g., specimen collection, handling, and storage), examination (an alytical) variables (e.g., reagent and test performance, instru ment calibration and maintenance, personnel requirements, and technical competence),postexamination (postanalytical) variables (e.g., reporting of results and interpretation), and documentation that the program is being followed meticu lously.

Quality management system

18
New cards

provides the guidelines for writing these procedures and policies

Clinical and Laboratory Standards Institute (CLSI)

19
New cards

urine specimens should be examined

within 2 hours.

20
New cards

used as a tool to document a problem at the point of discovery, describing what happened and the immediate corrective action taken.

internal laboratory quality improvement form

21
New cards

This enables the laboratory director to capture the information to determine the root cause analysis (RCA) and develop a preventive or corrective action plan.

internal laboratory quality improvement form

22
New cards

Calibration of centrifuges and accuracy of timers are customarily per formed every:

every 3 months, and there should be a record of the appropriate relative centrifugal force for each setting.

23
New cards

External Quality Assessment aka

Proficiency Testing

24
New cards

testing of unknown specimens received from an outside agency and provides unbiased validation of the quality of patient test results.

External Quality Assessment

25
New cards

mandates comparison testing for laboratory accreditation.

Clinical Laboratory Improvement Amendments (CLIA)

26
New cards

an alternative CLIA QC option that provides equivalent quality testing to meet the CLIA regulations for moderate- and high complexity tests and provider-performed microscopy procedures (PPMP) tests.

Individualized Quality Control Plan

27
New cards

With this option, the laboratory can deter mine the frequency of QC testing based on information about the test, the risk assessment, and the accreditation agencies’ requirements.

Individualized Quality Control Plan

28
New cards

requires risk assessment (RA), a quality control plan (QCP), and quality assessment (QA)

Individualized Quality Control Plan

29
New cards

identifies and evaluates potential problems that may occur in the entire testing process from preexamination through the examination and post examination processes.

risk assessment (RA),

30
New cards

establishes control procedures to reduce the possibility of reporting an inaccurate patient test result. It must include the number, type, and frequency of testing, as well as criteria for acceptable results of the QCs

quality control plan (QCP)

31
New cards

now the most common method for reporting results.

Electronic transmission/Electronic Result

32
New cards

an automated comparison of patient results with predetermined preapproved criteria, programmed into them

autoverification

33
New cards

(the lowest level of an analyte that a test can detect)

sensitivity

34
New cards

(the likelihood of measuring the analyte desired)

Specificity

35
New cards

Reporting Critical Results In Urinalysis

Time of telephone call

Initials of the person making the call

Name of the person receiving the telephone call

36
New cards

international effort to standardize both the classification of hazardous chemicals and the symbols used to communicate these hazards on labels and in SDS documentation

Globally Harmonized System (GHS)

37
New cards

Globally Harmonized System (GHS) standard label elements include

GHS hazard pictograms

signal words\

GHS hazard statement

38
New cards

Two levels of commercial controls are available for

osmometer, urine reagent strip tests, and human chorionic gonadotropin (hCG) kit tests

39
New cards

Temperatures of refrigerators and water baths should be taken

daily and recorded.

40
New cards

Calibration of centrifuges and accuracy of timers are customarily per formed every

3 months, and there should be a record of the appropriate relative centrifugal force for each setting.

41
New cards

Disinfection of centrifuges should be done routinely on a

weekly basis or after spills

42
New cards

Microscopes should be kept clean at all times and have an

annual professional cleaning

43
New cards

Automatic pipettes are ____ and ____ checked for accuracy and reproducibility.

initially and periodically

44
New cards

Deionized water used for reagent preparation is quality controlled by checking

pH and purity meter resistance on a weekly basis, bacterial count on a monthly schedule.

45
New cards

verify the accuracy (ability to obtain the expected result) and precision (ability to obtain the same result on the same specimen) of a test, and they are exposed to the same conditions as the patient specimens.

External Quality Control

46
New cards

ability to maintain both precision and accuracy

Reliability

47
New cards

Documentation of QC includes:

dating and initialing the material when it is first opened and recording the manufacturer’s lot number and the expiration date each time a control is tested and the test result is obtained.

48
New cards

Personnel assessment includes

education and training, continuing education, competency assessment, and performance appraisals. Each new employee must have documentation of training during orientation to the laboratory. This is a check list of procedures and must include the date and initials of the person doing the training and of the employee being trained. Up-to-date reference materials and atlases should be readily available, and documentation of continuing education must be maintained.

49
New cards

References to the study of urine can be found in the drawings of cavemen and in Egyptian hieroglyphics, such as the

Edwin Smith Surgical Papyrus

50
New cards

wrote a book on “uroscopy.”

Hippocrates

51
New cards

albuminuria by boiling urine

Frederik Dekkers’s

52
New cards

These charlatans, called “pisse prophets,” became the subject of a book published by

Thomas Bryant

53
New cards

examination of urinary sediment and to the development by

Thomas Addis of methods

54
New cards

introduced the concept of urinalysis

Richard Bright

55
New cards

nephron by the following renal functions:

Renal blood flow

Glomerular filtration

Tubular reabsorption

Tubular secretion

56
New cards

nephrons in Each kidney contains approximately

approximately 1 to 1.5 million functional units

57
New cards

human kidney contains two types of nephrons.

Cortical nephrons

Juxtamedullary nephrons

58
New cards

responsible primarily for removal of waste products and reabsorption of nutrients.

Cortical nephrons

59
New cards

primary function is concentration of the urine.

Juxtamedullary nephrons

60
New cards

have longer loops of Henle that extend deep into the medulla of the kidney

Juxtamedullary nephrons

61
New cards

supplies blood to the kidney

renal artery

62
New cards

human kidneys receive____ of the blood pumped through the heart at all times.

approximately 25%

63
New cards

located adjacent to the ascending and descending loops of Henle in juxtamedullary nephrons.

vasa recta

64
New cards

major exchanges of water and salts take place between the blood and the medullary interstitium. This exchange main tains the osmotic gradient (salt concentration) in the medulla, which is necessary for renal concentration.

vasa recta

65
New cards

total renal blood flow is approximately

1200 mL/min,

66
New cards

total renal plasma flow ranges from

600 to 700 mL/min.

67
New cards

several factors influence the actual filtration process.

cellular structure of the capillary walls and Bowman capsule,

hydrostatic pressure and oncotic pressure

feedback mechanisms of the renin–angiotensin–aldosterone system (RAAS).

68
New cards

glomerulus is located within

Bowman capsule,which forms the beginning of the renal tubule.

69
New cards

nonselective filter of plasma substances with molecular weights less than 70,000,

glomerulus

70
New cards

glomerulus consists of a coil of approximately

eight capillary lobes, the walls of which are referred to as the glomerular filtration barrier.

71
New cards

enzyme produced by the juxtaglomerular cells, is secreted and reacts with the bloodborne substrate angiotensinogen to produce the inert hormone angiotensin I

Renin

72
New cards

As angiotensin I passes through the alveoli of the lungs, what enzyme is used to convert it to angiotensin II

angiotensin-converting enzyme (ACE) changes it to the active form angiotensin II.

73
New cards

Angiotensin II corrects renal blood flow in the following ways:

  1. Dilates the afferent arteriole and constricts the efferent arteriole

2. Stimulates sodium reabsorption in the proximal convoluted tubule

3. Triggers the adrenal cortex to release the sodium-retaining hor mone aldosterone to cause sodium reabsorption and potassium excretion in the distal convoluted tubule and collecting duct

4. Triggers the hypothalamus to release antidiuretic hormone to stimulate water reabsorption in the collecting duct

74
New cards

As a result of the glomerular mechanisms, every minute, approximately

2 to 3 million glomeruli filter approximately 120 mL of water-containing low-molecular-weight substances.

75
New cards

Because this filtration is nonselective, the only difference between the compositions of the filtrate and the plasma is the

absence of plasma protein, any protein-bound substances, and cells.

76
New cards

Analysis of the fluid as it leaves the glomerulus shows the filtrate to have a specific gravity of

1.010 and confirms that it is chemically an ultrafiltrate of plasma.

77
New cards

2 to 3 million glomeruli filter

approximately 120 mL of water-containing low-molecular-weight substances.

78
New cards

Active transport

Glucose, amino acids, salts Chloride, Sodium

79
New cards

Passive transport

Water Urea Sodium

80
New cards

Glucose, amino acids, salts

Proximal convo luted tubule

81
New cards

Chloride

Ascending loop of Henle

82
New cards

Sodium

Proximal and distal convoluted tubules

83
New cards

Water

Proximal convo luted tubule

Descending loop of Henle

Collecting duct

84
New cards

Urea

Proximal convo luted tubule

Ascending loop of Henle

85
New cards

Sodium

Ascending loop of Henle

86
New cards

Movement of molecules across a membrane as a result of differences in their concentration or electrical potential on opposite sides of the membrane. These physical differences are called gradients.

Passive transport

87
New cards

Influenced by the concentration of the substance being transported. When the plasma concentration of a substance that is normally completely reabsorbed reaches a level that is abnormally high, the filtrate concentration exceeds the

maximal reabsorptive capacity (Tm) of the tubules, substance begins appearing ing in the urine.

88
New cards

plasma concentration at which active transport stops is termed the

renal threshold

89
New cards

Glucose appearing in the urine of a person with a normal blood glucose level is the result

tubular damage and not diabetes mellitus

90
New cards

major site for removal of these nonfiltered substances

proximal convoluted tubule.

91
New cards

creatinine, beta2-microglobulin (B2M), cystatin C, and, possibly, radioisotopes

primary substances used in clearance tests.

92
New cards

earliest glomerular filtration tests measured urea because of its presence in all urine specimens, as well as the existence of routinely used methods of chemical analysis.

Urea Clearance

93
New cards

a polymer of fructose, is an extremely stable sub stance that is neither reabsorbed nor secreted by the tubules. It is not a normal body constituent, however, and must be infused by IV at a constant rate throughout the testing period. Therefore, although inulin was the original reference method for clearance tests, current methods are available that are endogenous and can provide accurate GFR results.

Inulin Clearance

94
New cards

A test that requires an infused substance is termed an exogenous procedure and is seldom the method of choice if a suitable test substance is already present in the body (endogenous procedure)

Inulin Clearance

95
New cards

a waste product of muscle metabolism that is produced enzymatically by creatine phosphokinase from creatine, which links with adenosine triphosphate (ATP) to produce adenosine diphosphate (ADP) and energy. Because creatinine is normally found at a relatively constant level in the blood, it provides the laboratory with an endogenous procedure for evaluating glomerular function.

Creatinine Clearance

96
New cards

shown to be a good procedure for screening and monitoring GFR.

cystatin C

97
New cards

small protein (molecular weight 13,359) produced at a constant rate by all nucleated cells.

cystatin C

98
New cards

It is filtered readily by the glomerulus and reabsorbed and broken down by the renal tubular cells.

cystatin C. therefore, no cystatin C is secreted by the tubules, and the serum concentration can be related directly to the GFR.

99
New cards

recommended for pediatric patients, people with diabetes, the elderly, and patients who are critically ill.6 An advantage is that it is independent of muscle mass.

cystatin C

100
New cards

dissociates from human leukocyte antigens at a constant rate and is removed rapidly from the plasma by glomerular filtration.

Beta2-Microglobulin