Which method is used for hemoglobin concentration according to the PowerPoint?
A. Electrical impedance
B. Cyanmethemoglobin
C. Fluorescence only
D. Light microscopy
B. Cyanmethemoglobin
Rationale: The PowerPoint identifies the cyanmethemoglobin method for hemoglobin concentration
Electrical impedance is used for:
A. Cell counting and sizing
B. DNA sequencing
C. Antibody identification
D. Gram staining
A. Cell counting and sizing
Rationale: Impedance provides the number of cells and measures cell volume.
As a cell passes through the aperture, there is an:
A. Increase in electrical resistance
B. Decrease in electrical resistance
C. Increase in temperature
D. Decrease in voltage only
A. Increase in electrical resistance
Rationale: The cell causes an increase in resistance to the electrical current.
The increase in electrical resistance is proportional to:
A. Cell color
B. Cell volume
C. Cell age
D. Hemoglobin type
B. Cell volume
Rationale: In impedance technology, the change in resistance corresponds to cell volume.
Electrical resistance is measured as:
A. Small voltage pulses
B. Large electrical waves
C. Light beams
D. Sound waves
A. Small voltage pulses
Rationale: The analyzer measures resistance as small voltage pulses.
To be counted, a cell must measure:
A. Outside the threshold range
B. Within the threshold range
C. Above the threshold only
D. Below the threshold only
B. Within the threshold range
Rationale: Pulses are compared with threshold values, and cells must fall within the appropriate range to be counted.
RBCs and platelets are:
A. Counted at different times only
B. Sized and counted at the same time
C. Never counted by impedance
D. Counted only manually
B. Sized and counted at the same time
The WBC differential uses a focused:
A. UV lamp
B. Laser beam
C. X-ray beam
D. Infrared beam
B. Laser beam
Rationale: The flow cell uses a focused laser beam to count all five WBC types in a single pass.
Beckman Coulter WBC differential analysis uses:
A. Cell volume and electrical impedance
B. Only microscopy
C. Only fluorescence
D. Only absorption
A. Cell volume and electrical impedance
Rationale: Beckman Coulter uses cell volume and electrical impedance for WBC differential analysis.
Conductivity is used to:
A. Differentiate WBC populations
B. Measure only RBC count
C. Stain platelets
D. Measure urine specific gravity
A. Differentiate WBC populations
Light scatter provides information about:
A. Cell structure and shape
B. Patient age
C. Blood type
D. Specimen volume
A. Cell structure and shape
According to the PowerPoint, opacity measurements help determine the:
A. RBC count
B. Nuclear/cytoplasm ratio
C. Platelet count
D. Hematocrit
B. Nuclear/cytoplasm ratio
Rationale: Opacity measurements are helpful in distinguishing normal from abnormal lymphocytes by evaluating the nuclear/cytoplasm ratio.
The Sysmex X Series uses direct current with hydrodynamic focusing for:
A. RBCs and platelets
B. WBCs only
C. Hemoglobin only
D. Reticulocytes only
A. RBCs and platelets
Sysmex uses fluorescent flow cytometry and light scatter for:
A. WBCs and differentials
B. Only RBCs
C. Only hemoglobin
D. Only platelets
A. WBCs and differentials
Rationale: These methods are used for WBCs, differentials, NRBCs, and reticulocyte counts.
Which analyzer technology can distinguish blasts from other immature WBCs?
A. Sysmex X Series
B. Manual hematocrit
C. Microhematocrit centrifuge
D. Urinalysis analyzer
A. Sysmex X Series
Rationale: The PowerPoint states that the Sysmex X Series can distinguish blasts from other immature WBCs.
The Abbott Cell-Dyn series uses:
A. MAPS
B. RACE
C. PASS
D. RAAS
A. MAPS
Rationale: MAPS stands for Multiple Angle Polarized Scatter.
The Abbott Cell-Dyn series uses which combination of technologies?
A. Optical scatter, fluorescent technology, impedance, and absorption
B. Only impedance
C. Only microscopy
D. Only conductivity
A. Optical scatter, fluorescent technology, impedance, and absorption
Rationale: The PowerPoint lists all four technologies for CBC and reticulocyte counts.
. The WBC histogram lymphocyte range is:
A. 2–20 fL
B. 35–90 fL
C. 90–160 fL
D. 160–450 fL
B. 35–90 fL
The WBC histogram mononuclear cell range is:
A. 2–20 fL
B. 35–90 fL
C. 90–160 fL
D. 160–450 fL
C. 90–160 fL
The WBC histogram granulocyte range is:
A. 2–20 fL
B. 35–90 fL
C. 90–160 fL
D. 160–450 fL
D. 160–450 fL
The platelet histogram threshold range is:
A. 2–20 fL
B. 35–90 fL
C. 90–160 fL
D. 160–450 fL
A. 2–20 fL
A 5-part differential includes:
A. RBCs, platelets, reticulocytes, NRBCs, and blasts
B. Segs, lymphs, monos, eos, and basos
C. Neutrophils, RBCs, monocytes, platelets, and eosinophils
D. Only granulocytes
B. Segs, lymphs, monos, eos, and basos
Rationale: A 5-part differential consists of segmented neutrophils, lymphocytes, monocytes, eosinophils, and basophils
Hematology analyzer QC is performed:
A. Only once a year
B. Daily, weekly, monthly, and after maintenance procedures
C. Only when results look abnormal
D. Only after calibration
B. Daily, weekly, monthly, and after maintenance procedures
Rationale: The PowerPoint lists QC at these intervals and following instrument maintenance.
Stabilized controls are used to evaluate instrument:
A. Color
B. Precision
C. Patient diagnosis
D. Blood type
B. Precision
Rationale: Instrument precision is evaluated using stabilized controls, with control values required to remain within established ranges.
When a CBC analyte is flagged, the first action according to the PowerPoint is to:
A. Immediately report the result
B. Retest it on the hematology analyzer
C. Discard the specimen
D. Change the patient's diagnosis
B. Retest it on the hematology analyzer
Rationale: Any flagged CBC analyte should be retested on the hematology analyzer.
Which organization/program sends proficiency testing materials to laboratories?
A. CAP
B. CDC only
C. OSHA
D. FDA only
A. CAP
Rationale: The College of American Pathologists (CAP) provides survey/proficiency testing materials, and laboratories must successfully participate