What links photon energy, wavelength and frequency?
E = hν = hc/λ. Shorter wavelength means higher frequency and higher energy. So UV photons carry more energy than visible, and visible more than IR.
Why does UV-Vis light cause electronic transitions?
Photon energies at 200-760 nm (roughly 50-1000 kJ/mol) match the energy gaps between electronic states. A photon is only absorbed if its energy equals the gap.
How do you calculate the energy of one mole of photons?
E = hc/λ per photon, with λ converted from nm to m (×10⁻⁹). Multiply by NA (6.022×10²³) for J/mol, then divide by 1000 for kJ/mol.
What is an electronic transition?
Promotion of an electron from a lower-energy occupied molecular orbital (HOMO) to a higher-energy unoccupied orbital (LUMO).
Why are UV-Vis peaks broad bands rather than sharp lines?
Each electronic state has its own vibrational levels. The transition starts in the lowest vibrational level of the ground state and can end in many vibrational levels of the excited state. These closely spaced transitions, broadened further by the solvent, merge into one band.
Why are transitions drawn as vertical arrows on the potential-energy diagram?
Electrons move far faster than nuclei, so the nuclei do not move during the transition and the interatomic distance stays constant.
Why is the excited-state curve shifted to a longer bond length?
The electron has been promoted into a higher orbital that is less bonding, so the bond is weaker and longer in the excited state.
What is plotted in an absorption spectrum, and what does a peak mean?
Absorbance against wavelength. A peak is a wavelength whose photon energy matches an electronic transition in the molecule.
Why does a compound have colour?
It absorbs some visible wavelengths (400-760 nm). The rest are transmitted or reflected to your eye, and your brain reads that mixture as the colour.
When is a compound colourless?
When it has no significant absorption from about 400 to 700 nm. All visible light passes through. Any absorption it does have is in the UV, which the eye cannot detect.
Does UV absorption affect the colour you see?
No. Colour is decided only by the visible region. A compound can absorb strongly in the UV and still be colourless.
What does colourless actually mean?
No absorption in the visible range. It does not mean no absorption at all, because a spectrophotometer can still detect UV absorption.
When does a compound look black, and when white or clear?
Black: it absorbs all visible wavelengths, so no visible light returns. Clear or white: it absorbs none of them.
How do you predict colour from an absorption spectrum?
Check 400-700 nm. If nothing absorbs there, it is colourless. Otherwise find which colours are absorbed. The colour seen is what is left, roughly the complementary colour.
What is the complementary colour rule?
Absorbs violet (400-430) and looks yellow-green. Blue (430-490) looks yellow-orange. Green (490-560) looks magenta. Yellow (560-590) looks violet-blue. Orange (590-620) looks blue. Red (620-750) looks cyan.
A spectrum has one peak at the blue end and one at the red end. What colour is the compound?
Green. Blue and red are removed, so the middle (green, yellow) is transmitted or reflected. The colour you see is the gap between the peaks. This is why chlorophyll-containing leaves look green.
Is the leftover light "emitted"?
No. For ordinary colour it is transmitted or reflected. Emission only applies to fluorescence, where the molecule gives off new light at a longer wavelength.
Why is chlorophyll green?
Chlorophyll a and b absorb strongly in the blue (about 430-470 nm) and red (about 640-680 nm) and barely absorb green. Green is therefore transmitted or reflected.
What is a chromophore?
The part of a molecule responsible for absorbing a UV or visible photon, for example C=O, C=C, a benzene ring or a conjugated polyene. The strongest absorbers contain conjugated systems.
Why does conjugation move absorption to longer wavelength?
In a conjugated system (alternating double and single bonds) the π electrons delocalise over the whole system. This shrinks the HOMO-LUMO gap, so less energy (a longer wavelength) is needed for the transition.
What does more conjugation do to λmax and ε?
λmax shifts to longer wavelength (roughly +30-40 nm per extra C=C) and ε increases. A longer conjugated chain means a smaller gap and a stronger absorber.
How many conjugated C=C bonds are needed to absorb visible light?
Roughly 8 or more for a simple polyene. Short conjugated systems, isolated C=C or C=O groups and benzene all absorb only in the UV.
How do you decide which of several compounds has the longest λmax?
Find the one with the longest conjugated system. It has the smallest HOMO-LUMO gap and therefore the longest λmax.
Two isomers: one absorbs at ~223 nm and the other below 200 nm. How do you tell which is which?
The isomer with alternating C=C-C=C (conjugated) absorbs at 223 nm. In the other, an sp³ CH₂ sits between the double bonds and breaks conjugation, so each C=C behaves like an isolated alkene and absorbs below 200 nm.
How can UV-Vis detect an impurity with a shorter conjugated system?
Removing one conjugated C=C increases the HOMO-LUMO gap, so the impurity absorbs at a shorter wavelength than the product. It shows up as an extra shoulder or peak at lower wavelength that the pure reference lacks.
Why is UV-Vis alone poor for identifying an unknown compound?
The spectrum has few, broad bands that reflect almost only the chromophore. Compounds with similar chromophores give near-identical spectra. UV-Vis is good for quantification and detecting changes in conjugation, but structure determination also needs IR, NMR and MS.
What does the size of ε tell you?
ε above about 10,000 means a strongly allowed transition, typical of conjugated systems. ε below about 100 means a weakly allowed transition, such as a simple C=O.
Same concentration and path length, but A(X) is 10× A(Y). What can you conclude?
ε(X) is 10× ε(Y), because A is proportional to ε when c and l are equal. X is a stronger absorber with a more probable transition. It says nothing about λmax.
Define absorbance.
A = log₁₀(I₀/Iₜ). It is a log scale: A = 1 means 10% of the light is transmitted, and A = 2 means 1%.
State the Beer-Lambert law and its units.
A = ε × c × l. ε is the molar absorption coefficient (dm³ mol⁻¹ cm⁻¹ or L mol⁻¹ cm⁻¹), c is concentration (mol dm⁻³) and l is path length (cm). A has no units.
Why do we measure absorbance rather than transmission?
A is directly proportional to concentration, which gives a straight-line calibration graph. Transmission falls exponentially with concentration.
Why measure at λmax?
ε is largest there, so the sensitivity is greatest and a small error in wavelength changes A the least. ε is also quoted at λmax.
Why does the Beer-Lambert plot curve at high concentration?
Above A of about 1.5 the law no longer holds. Very little light reaches the detector, so stray light and noise dominate, and solution effects add to the deviation. A stops being proportional to c, and the true concentration is underestimated.
What absorbance range gives reliable quantitative results?
About 0.1-1.0 (the linear range, up to about 1.5 at most). Below about 0.05 the signal is too noisy, and above about 1.5 the response is non-linear.
Why dilute a sample with A = 1.9 when the standards only cover 0.05-0.80?
A = 1.9 is outside the calibrated range, so using it means extrapolating, and Beer-Lambert is non-linear up there. Dilute by a known factor, re-measure within the range, read off c, then multiply by the dilution factor.
Why interpolate, never extrapolate, on a calibration line?
Your standards only prove the line is straight within the range they cover. Beyond it you have no evidence of linearity.
What does blanking the instrument do?
Zeroing with a cuvette of solvent or reagent (no analyte) removes absorbance from the solvent, reagent and cuvette, so only the analyte's absorbance is measured.
List the good practices for a UV-Vis concentration measurement.
Standards that bracket the sample. A between about 0.1 and 1.0. Blank with solvent or reagent. Measure at λmax. Use the same cuvette path length for standards and samples. Never extrapolate.
What happens to A if you change the path length?
A is proportional to l. A 0.20 cm cuvette gives 0.20× the absorbance of a 1.00 cm one. Doubling c while halving l leaves A unchanged.
How do you get ε from a calibration graph?
Plot A against c. The gradient equals ε × l, so ε = gradient / l. To find an unknown, c = A / gradient (or A / εl).
How do you read an unknown concentration from a calibration curve?
Use the line, not just a visual guess. Divide the unknown's absorbance by the gradient (c = A / gradient), and check the result is inside the range of the standards.
What are the three stages of fluorescence?
1) Absorption: a photon promotes an electron to an excited state. 2) Vibrational relaxation: energy is lost as heat and the electron drops to the lowest vibrational level of the excited state. 3) Emission: a lower-energy photon is released as the electron returns to the ground state.
Why does a fluorophore emit at a longer wavelength than it absorbs?
Energy is lost as heat in vibrational relaxation before emission, so E(emitted) < E(absorbed). Since E = hc/λ, lower energy means longer wavelength.
What is the Stokes shift?
The difference between the absorption maximum and the emission maximum. It is caused by the energy lost in vibrational relaxation.
Why is the Stokes shift essential for fluorescence imaging?
The excitation light is far more intense than the weak emission, so the two must be separated. Filters block the excitation wavelengths and pass the emission, giving a bright signal on a dark background. Heavy overlap makes this impossible without losing signal.
How is the colour of fluorescence different from ordinary colour?
Ordinary colour is the complement of what was absorbed. Fluorescence is the emission peak, at a slightly longer wavelength than the absorption peak, with a spectrum that is roughly a mirror image of the absorption.
How do you choose the emission filter for a fluorophore?
Pick a band-pass filter that covers most of the emission band and blocks the excitation wavelength. For example, with excitation at 488 nm and emission centred near 525 nm, use about 510-560 nm.
Two dyes are equally bright. Which is easier to image with simple filters?
The one with the larger Stokes shift (emission well separated from absorption), because the excitation can be blocked without losing much emission.
What is the difference between fluorescence and phosphorescence?
In fluorescence the electron returns directly from an excited singlet state, which is fast. In phosphorescence the molecule first crosses to a triplet state, so emission is slower and at even lower energy.
Why does fluorescence give good contrast?
You detect only emitted light against a dark background. The signal is specific to the molecule, so you are artificially "engineering a signal".