1/29
Looks like no tags are added yet.
garb items
low lint
gown or coveralls w/ sleeves snug around wrists & enclosed at neck
disposable shoe & head covers
disposable facial hair cover
face mask
sterile powder-free gloves
sample garbing procedure
IN ORDER
on dirty side of ante room
Head and facial hair covers
Face masks/eye shields
Shoe covers while stepping over line of demarcation to clean side
on clean side of ante room
Wash hands w/ proper technique
Don non-shedding gown
upon entering buffer area
. Perform hand sanitizing procedure
Don sterile, powder-free gloves
What is media-fill testing?
a test used to evaluate whether a person can properly perform aseptic (sterile) compounding.
mandatory for everyone who compound
media filling test according to USP <797>
for testing procedures, use the most difficult and challenging
compounding procedures and processing conditions encountered by the person
during a work shift (e.g., the most manipulations, most complex flow of materials,
longest time to compound), replacing all the components used in the CSP’s with
microbial growth medium.
compouding facilities
must minimize risk of contamination of CSPs
air quality must be met with PECs & SECs
ante-room & buffer room must meet air quality
engineering controls
Primary Engineering Controls
Secondary Engineering Controls
Primary Engineering Controls
device or zone that provides an ISO Class 5 air quality environment for sterile compounding (eg Laminar Airflow Workbench
secondary Engineering Controls
The area where the PEC is placed (eg cleanroom)
air quality requirements
ante-room minimum
ISO Class 8 (if have positive pressure buffer room)
ISO Class 7 (if have negative pressure buffer room)
Buffer room minimum
ISO Class 7
PEC
ISO Class 5 or better if compounding Category 1, Category 2, and Category 3 CSPs
If compounding only Category 1 CSPs, the PEC may be placed in an unclassified segregated compounding area
other clean room suite requirements
Temperature 20 degrees Celsius
Humidity <60%
Pressure differential monitoring system
The ante-room must have a line of demarcation to separate the clean side from the dirty side
The ante-room is entered through the dirty side/room, and the clean side/ room is the area closest to
the buffer room.
Air sampling every 6 months
Surface sampling monthly
Interior of PEC and equipment in PEC, areas near the PEC, frequently touched surfaces
Cleaning and disinfecting requirements as outlined in USP797
SCA
unclassified area, w/o am ante-room or buffer room
only cat 1 csps can be compounded here
where SCA should and should not be placed
should:
away from unsealed windows, doors that connect to outdoors, traffic flow
should not:
environmental control challenges (e.g., restrooms, warehouses, or food preparation
areas) could negatively affect the air quality of the PEC within the SCA
visible perimeter must establish the boundaries of the SCA.
primary engineering controls
LAFW (Laminar Airflow Workbench)
BSC (Biological Safety Cabinet)
CAI (Compounding Aseptic Isolator)
CACI (Compounding Aseptic Containment Isolator)
laminar airflow system
system provides ISO class 5 or better conditions
undirectional airflow, horizontal or vertical
how to filter room air
via a HEPA filter
remove particles, dust, bacteria
filters 99.97% of particles 0.3microns in size or larger
directional air flow will blow out contamination as it enters the hood (up to a point)
horizontal LAFW
maintain a direct, open path btw HepA filter & area inside work station
avoid blocking critical sites from direction of “first air”
small items close to HEPA filter & larger to opening of work station
nonsterile items downstream from sterile ones
hand movements should not disturb airflow pattern
work area should be 3 inches from back of LAFW & 6 inches inside of front of workstation
swab all surfaces w/ alcohol
spray gloves w/ 70% IPA
first air
air released from the HEPA filter
how to sanitize w/ 70% alcohol
wipe in direction away from filter
back to front across vial stopper
Vertical LAFW
Place larger containers toward the back of the work area
Do not block the airflow from above
Do not have hands going over the top of objects in hood
vials: procedure
do not block “first air”
hold vial so you can see needle in vial
how should items be wired down
w. sporicidal agent, disinfectant, or sterile 70% IPA before entering cleanroom suite and SCA’s
Again with 70% IPA before placing in PEC (hood)
can cardboard be in cleanroom
NOOO
sterile testing required for
not for category 1 CSPs
may be required for Category 2 (depending on BUD assigned)
required for Category 3 CSPs
Bacterial endotoxin testing
Required if sterility testing done or if one or more nonsterile ingredient used
Must not exceed limits listed in USP<85>
introducing items into sec & pec
. Transitioning into the Ante Room (ISO 8)
Action: items from (dirty side) across the demarcation line —> the clean side of the ante room.
Sanitization: wipe items w/ germicide, sporicidal agent, or 70% IPA wipe
2. Transitioning into the Clean Room (ISO 7)
Action: items from the ante room- —> SEC cleanroom.
Sanitization: disinfect items w. sterile 70% IPA wipe
3. Transitioning into the PEC (ISO 5)
Action: Introducing items directly into the Primary Engineering Control (such as a laminar airflow workbench [LAFW], biological safety cabinet [BSC], or compounding aseptic isolator [CAI]).
Sanitization: wipe w/ sterile 70% IPA wipe right as items are placed into the ISO 5 zone
do not disrupt unidirectional airflow or introduce contaminants into the direct compounding area (DCA).
sec & pec
SEC (Secondary Engineering Control): The cleanroom suite, comprising the cleanroom (ISO 7) and ante room (ISO 8).
PEC (Primary Engineering Control): The ISO 5 device or zone (e.g., LAFW, BSC, CAI, CACI) that provides an ultra-clean environment for actual compounding activities.
require sanitizing at every step
sterile 70% isopropyl alc or other disinfectant to sanitize materials at each step to higher ISO level
a drug vial will be wiped 2 times from out to into the hood
antetoom —> hood
iso 8 (ante-room) —> iso 7 (clean room) —> iso 5 ( hood)
master formulation record for compounded sterile products
Name, strength or activity, and dosage form
ingredients and amounts of each
characteristics of components (e.g. particle size, solubility, etc.)
Type and size of container-closure system
Complete instructions for preparation, including:
Equipment, supplies, steps, special precautions
Physical description of compound
BUD and storage requirements
Reference used to determine stability
Quality control procedures
Any info needed to describe process and ensure repeatability
labeling
Assigned internal id number (e.g. prescription #)
Active ingredients and amounts, or concentrations
Storage conditions (if other than room temp)
BUD
Dosage form
Total amount of volume
If single dose container or multiple dose container, label as such
Route of administration, special handling instructions, warning statements
Contact information of compounding facility, if sent out
Label stating that product is compounded