1/58
Looks like no tags are added yet.
capabilities and limitations of duplex upper extremities
localize stenosis/occlusion/aneurysm & hemodialysis access graft surveillance
connection between artery and vein. allows for greater volume flow as needed with hemodialysis
hemodialysis access graft/ surgical AVF (fistula graft)
types of AVFs
autologous & synthetic
— = brescia-cimino. radial a to cephalic v = self
autologous AVF
— = straight or looped. (ie- brach a to ax v) = isn’t your own vessel
synthetic AVF
upper extremity eval technique
7-9 MHz linear array transducer
arm extended laterally and 45 deg to body = pledge position
check for thrill if evaluating for hemo access
a vibration felt under skin due to high velocity, turbulent flow
thrill
when evaluating for a hemodialysis access graft you also need to evaluate
inflow artery
arterial anastomosis
graft body
venous anastomosis
outflow vein
normal interpretation of an upper extremity navite arteries
normal high resistance = triphasic or biphasic
stenosis interpretation of an upper extremity arteries
no velocity criteria! qualitative only
only basis for criteria is — and knowldge of normal vs obstructive waveform contours
stenosis profile
focally elevated vel and PST =
stenosis
normal hemodialysis prox art (inflow) waveform =
low resistance / inc EDV
normal hemodialysis dis art =
back to normal high resistance (triphasic)
normal hemodialysis fistula =
low resistance / high PSV & high EDV
normal hemodialysis prox vein (outflow) =
pulsatile
normal flow in graft =
high velocity & turbulent

normal hemodialysis waveforms
thumping high resistance in prox artery or graft =
graft occlusion
low velocity dampened, continuous =
proximal inflow problem
abnormal findings for fistula graft: focal elevated velocity =
graft stenosis
most common location of focal elevated velocity/graft stenosis =
outflow vein
abnormal findings for fistula graft: perigraft fluid =
infection (clinical: warm, red, tender)
— = reversal of flow in the distal artery
steal syndrome
capabilities and limitations of duplex of the lower extremities
eval location and severity of stenosis vs occlusion / %DR / aneurysm & bypass graft and stent surveillance
connect artery to artery to reroute blood flow in the presence of significant arterial obstruction
bypass graft
if there is a bypass graft, important areas to be eval
inflow artery, prox anastomosis, graft body, distal anastomosis, outflow artery
all successfull bypasses must
start above disease (patent inflow), have a conduit (graft), and end after any disease (patent outflow)
types of arterial bypass grafts
synthetic, in situ saphenous vein graft (autologous), reversed saphenous vein graft (autologous)
synthetic = —
PTFE
— = vein is kept in place, removed from venous and connected to arterial. branches must be ligated and valves removed
in situ saphenous vein graft (autologous)
what do you need to eval for in a synthetic arterial bypass graft
anastomosis sites for possible leakage
what do you need to eval for in an in situ saphenous vein graft
body due to risk of AVF from branches or stenosis from residual valves
the tool that removes the vein valves for in situ saphenous vein bypass graft
valvutome
— = vein is removed and flipped upside down. branches ligated. valves kept in place since now allow for blood to move in right direction
reveresed saphenous vein graft
what do you need to eval for in a reversed saphenous vein graft
prox anastomosis due to small size
stenosis velocity criteria -
prestenotic to stenotic ratio
prestenotic to stenotic ratio is the —
proximal PSV compared to highest stenostic PSV
2:1 prestenotic to stenotic ratio means
greater or equal to a 50% diameter reduction (PSV doubles at stenosis)
4:1 prestenotic to stenotic ratio means —
a greater than or equal to 75% diameter reduction (PSV quadruples at stenosis)
any velocity > 400cm/s (for only the L.E) =
greater than or equal to 75% diameter reduction
the prestenotic to stenotic ratio criteria applies to —
both native arteries and bypasses
additional bypass surveillance criteria
look for following chnages from past study
decrease of 30cm/s in the same graft segment from one study to next
change or deterioration
decrease in ABI >0.15
retrograde flow in native artery at distal anastomosis is —
normal
flow moves into — of native artery
lower pressure
additional findings of lower extremities
aneurysm, pseudoanerysm
l.e ameurysm:
increase in diameter >50%. peripherally most likely seen in pop
l.e pseudoaneurysm:
post procedure. connecting channel or neck must be documented. to and dro flow (bidirectional)
intraoperative US of l.e: (12-15MHz)
main focus is check patency of anastomosis, intimal flaps, platelet aggregation
based on type of bypass, attention focused in following areas:
synthetic: anastomosis
reversed: proximal connection (small prox site)
in situ: residual valves and branches
what vessel is most likely to have disease if the right subclavian artery demonstrates a monophasic, dampened low velocity waveform
brachiocephalic artery
what is most common reason for failure of hemodialysis access graft
outflow vein stenosis
the proximal SFA PSV is 80cm/s and the following segment has a peak of 260cm/s. how is this interpreted
greater than or equal 50% DR
which of the following requires removal of venous valves?
in situ saphenous vein graft
what is the significance of an acceleration time of 114msec at both CFA’s
aortoiliac disease
the most common location for arterial obstruction in the lower extremitise
distal SFA
what is the expected flow pattern in artery proximal to the brescia-cimino fistula
low resistance
what is the significance of retrograde flow in the native vessel at the distal anastomosis of an in situ vein graft
normal
what would indicate a total occlusion of the hemodialysis access graft
little or no diastolic flow in the proximal artery