1/27
Vocabulary practice flashcards covering radiation characteristics, x-ray tube components, physics concepts, and image resolution principles.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Radiation
Energy in transit in the form of high-speed particles and electromagnetic waves.
Non-Ionizing Radiation
Radiation that does not possess enough energy to separate molecules or remove electrons from atoms (e.g., microwaves, ultraviolet [UV] light).
Ionizing Radiation
Radiation with sufficient energy to remove tightly bound electrons during interaction with an atom; characterized by very short wavelengths (e.g., gamma rays, x-rays).
X-rays
Electromagnetic waves or photons not emitted from the atomic nucleus, but normally produced by energy changes in electron orbital shells or when electrons decelerate.
Gamma Ray and X-ray Origin Difference
Gamma rays are emitted directly from the atomic nucleus and possess higher energy, whereas x-rays are emitted outside the nucleus from energy changes in electrons.
Photon
A single x-ray or particle of light that transports energy across space in discrete packets or units.
Wavelength
The linear distance measured from crest to crest (peak to peak) of a wave.
Frequency
The number of complete wave cycles that occur per second (cycles/sec).
Speed of X-rays
The constant velocity at which x-rays travel, equal to the speed of light (186,000miles per second).
Heterogeneous Beam
An x-ray beam composed of photons possessing varying, non-uniform energy levels.
Cathode
The negatively charged electrode inside the x-ray tube that serves as the source of electrons, typically composed of tungsten due to its high melting point.
Focusing Cup
A structure housing dual filaments in the cathode that prevents electrons from spreading and streamlines them into a focused beam toward the anode target.
Space Charge
The electron cloud that accumulates around the cathode filament when heated to incandescence.
Thermionic Emission
The liberation of electrons from a filament surface caused by thermal energy and heating.
Milliamperage (mA)
The tube current parameter that regulates filament temperature, heat, and the total quantity of electrons released.
Tube Current
The stream of free electrons traveling from the cathode to the positive anode, measured in milliamperes (1mA=10001amp).
Bremsstrahlung
The braking process that produces x-ray photons when rapidly moving electrons suddenly slow down upon striking the anode target.
Anode Plate Composition
Target materials consisting primarily of tungsten, molybdenum, and rhenium, selected for their high melting points, high atomic numbers, and thermal conductivity.
Prepare Stage
The preparatory tube phase during which the anode accelerates to 4,000revolutions per minute to dissipate heat and the cathode filament heats based on the selected mA.
Expose Stage
The phase that applies high kilovoltage to accelerate the liberated electrons across the vacuum gap toward the rotating target.
Kilovoltage (kV)
The electrical potential stepped up in the tube circuitry (1kilovolt=1,000volts) that determines electron speed, photon penetrating power, and beam quality.
Focal Spot
The specific area along the rotating anode track struck by the electron beam, which uniquely determines radiographic resolution and sharpness.
Actual Focal Spot
The physical area on the anode target struck by the electron beam, which dictates thermal and electrical load capacity.
Effective Focal Spot
The projected area of the focal spot directed downward toward the patient and image receptor.
Line Focus Principle
The geometric principle using an angled anode target so the actual focal spot remains large for heat dissipation while creating a smaller effective focal spot for sharper resolution.
General Radiography Target Angle
An anode angle range of 12∘ to 17∘, balancing photon bounceback prevention against self-absorption within the target material.
Blooming
The enlargement of the electron cloud and focal spot beyond normal dimensions at high mA settings, which can cause thermal stress cracks on the anode over time.
Resolution
The total amount of useful diagnostic information on an image, defined as the ability to differentiate two adjacent structures as separate and distinct.