1/50
Vocabulary flashcards covering target volumes (ICRU Reports 50 & 62), external beam equipment, treatment planning modes, and ASTRO clinical staffing recommendations based on the lecture notes.
Gross Tumor Volume (GTV)
The gross demonstrable extent and location of the malignant growth (visible, palpable, or demonstrable through imaging), which may also substitute a tumor bed.
Clinical Target Volume (CTV)
The tissue volume containing a demonstrable GTV and/or subclinical microscopic malignant disease, representing the true extent and location of the tumor.
Internal Margin (IM)
A margin added to the CTV to compensate for internal physiologic movements and variations in size, shape, and position of the CTV.
Internal Target Volume (ITV)
The volume defined as CTV+IM, designed to compensate for internal physiologic movements and positional variations of the CTV.
Setup Margin (SM)
A margin added to account for patient movement and uncertainties in treatment setup positioning.
Planning Target Volume (PTV)
The geometrical concept used for treatment planning, calculated as CTV+combined IM and SM (or ITV+SM), to ensure the prescribed dose is absorbed by the target.
Organ at Risk (OR)
An organ or sensitive normal tissue whose sensitivity to radiation may significantly influence treatment planning and/or prescribed dose.
Planning Organ at Risk Volume (PRV)
A volume defined around an Organ at Risk (OR) that incorporates margins for internal movements and setup uncertainties for treatment-planning purposes.
Treated Volume
The volume of tissue enclosed by the isodose line that covers the Planning Target Volume (PTV).
Irradiated Volume
The volume of tissue receiving a significant dose relative to tissue tolerance, defined as 50% of the dose.
ICRU
International Commission on Radiation Units and Measurements, which provides standard definitions for treatment volumes and radiation dose reporting in reports such as Report 50 and Report 62.
Charged Particle Beams
External radiation modalities including electrons (6-20MeV) and protons, characterized by delivering practically no exit dose and less integral dose.
Electronic Portal Imaging Device (EPID)
An accelerator-mounted localization system incorporating a kVp source for radiographic verification, online fluoroscopic mode, and cone-beam CT (CBCT).
Inverse Planning
A treatment planning method where the planner specifies desired dose distribution limits, and the computer algorithm (e.g., Pinnacle, Eclipse, RayStation) generates the plan.
Radiation Oncologist
A physician responsible for formulating the overall treatment plan and dose prescription, with a minimum required staffing of one per facility.
Medical Physicist
A specialist responsible for applying radiation science to ensure treatment plans are accurate and scientifically valid, requiring at least one per facility.
Medical Dosimetrist
A professional who assists the physicist with treatment planning and quality assurance, with a recommended staffing ratio of approximately one per 250 patients treated annually.
Radiation Therapist
A team member responsible for delivering the daily radiation treatment, with a recommended staffing ratio of approximately one per 90 patients treated annually.
Proximal vs distal
Proximal refers to a position closer to the point of attachment or to the trunk of the body, while distal refers to a position farther away from that point.
loss of sight happens at a cumulative dose to the optic chiasm at ___ and a single dose of ___
>50 gy, >10gy
functional alteration of the salivary glands is called
xerostomia
function of the epiglottis
flap of tissue that covers the air passage to the lungs and channels food to the esophagus
pharyngeal constrictors are what
swallowing muscles
dose constraint for hippocampal avoidance
hippocampus - v10<50, max dose is less than 16gy
max dose for optic chiasm and nerve
54gy
dose to cochlea
less than or equal to 45, for srs less than or equal to 14
Sup to inf for pharynx, larynx, glottis
naso, oro, hypo, larynx (supraglottis, glottis, subglottis)
which volume represents the true extent and location of the tumor
ctv
epid
electronic portal imaging device
HU for air, water, bone
-1000,0,up to 1000
most common types of mri scans
t1 and t2
contrast for mri
gadolineum
purpose of a pet scan
staging extent of disease, cancer detection, defining the target volume
MU
measure of output for linacs
dmax
depth at which electron equilibrium occurs for photon beams, the point where dose reaches its max value
dmax co60
0.5 cm
dmax 6mv
1.5 cm
dmax 15mv
3 cm
SAD
source to axis distance, source of photons to the isocenter
Example: a 10 x10cm field size is set on the collimator, the
square treatment field measures ___ at the
isocenter
10cm x 10cm
composite plan
a plan which includes all tx courses, primary + boost
co-axial beams
share the same CA
coplanar
beam central axis enters on the same plane as cax cross section
Integral dose (ID)
volume integral of the dose deposited in a pt and is equal to the mean dose times the volume irradiated to any dose
the 105% line is renormalized to 100% . What would the 100% ISL become?
100/1.05=95.3
SSD OR SAD, which is usually normalized to isocenter
sad
brain dose dmax
less than 60
brain stem doses, dmax for whole organ and srs
dmax less than 54gy, srs less than 12.5 gy
optic nerve/chiasm doses
dmax less than 55, srs dmax less than 12
parotid doses, bilateral, unilateral
mean dose less than 25.20
spinal cord doses
dmax 50, srs dmax 13