Construction Materials Exam 2

0.0(0)
Studied by 2 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/112

encourage image

There's no tags or description

Looks like no tags are added yet.

113 Terms

1
New cards

Endogeneous

Inward growth (palm trees)

2
New cards

Most commonly used tree growth type for building

Exogeneous

3
New cards

Exogeneous

Outward growth in rings

4
New cards

Deciduous

Broadleaf, hardwood

5
New cards

Coniferous

Cone bearing (evergreen), softwood

6
New cards

Deciduous examples

Oak, ash, maple, walnut

7
New cards

Coniferous examples

Douglas fir, pine, spruce, cedar

8
New cards

Spring ring growth

Light ring, fast with thin hollow walls

9
New cards

Summer ring growth

Dark ring, thick strong wall growth

10
New cards

Wider annual rings indicate:

Fast growth rate

11
New cards

Pith

Center stem

12
New cards

Heartwood

Second layer, provides structural support

13
New cards

Sapwood

Third layer, carries sap

14
New cards

Cambium

Fourth layer, growth area, very thin

15
New cards

Inner/outer bark

Outer layers of tree

16
New cards

Radial axis

Perpendicular to growth

17
New cards

Tangential axis

Parallel to growth, weakest

18
New cards

Longitudinal axis

Parallel to grain, strongest

19
New cards

Cellulose

50% of wood, a strand-forming polymer

20
New cards

Fibrils

Strands formed by cellulose

21
New cards

Wood fibers

Cell walls made up of fibrils

22
New cards

Lignin

“Glue” that binds tubes together

23
New cards

% of lignin in softwood?

23-33%

24
New cards

% of lignin in hardwood?

16-25%

25
New cards

Fiber Saturation Point

MC when wood cells are saturated but no free water exists

26
New cards

MC>FSP

Changes in MC only affect density and wet weight of wood

27
New cards

MC<FSP

Typical after mill, small changes lead to great effects in all properties of wood

28
New cards

Ratio of % shrinkage to % MC

1% shrinkage per 5% MC

29
New cards

Dimensional Lumber

Light framing: studs, joists, beams, rafters, trusses, decking. 2×4, 2×6

30
New cards

Heavy Timber

Heavy framing: railroad ties, landscaping. 4×6, 6×6, 8×8

31
New cards

Flat Sawing

Lowest quality, grain is <45 deg. from flat side of saw

32
New cards

Rift Sawing

Grain is 45-80 deg. from flat side of saw

33
New cards

Quarter/Edge Sawing

Highest quality, grain is 80-90 deg. from flat side of saw

34
New cards

Seasoning step of lumber production

Drying of wood

35
New cards

Uneven shrinkage

What part of the seasoning process can cause defects?

36
New cards

Method of seasoning wood

Combo of:

Air drying (cheap and slow)

Kiln drying (expensive and fast)

37
New cards

MC of wood after cut

30-200%

38
New cards

MC of wood after mill

15%

39
New cards

Surfacing step of lumber production

Planing, taking 1/4”+ from each side

40
New cards

What are the real dimensions of a 2×4 and why?

1.5×3.5, because the dimensions are based on the size before the surfacing step

41
New cards

A “dressed” piece of wood

Surfaced on all four sides

42
New cards

Causes of lumber defects

Natural growth, seasoning, disease, insects, faulty processing

43
New cards

Knot

Most common defect, the site of where a branch grew

44
New cards

Shake

Separation between annual rings

45
New cards

Wane

Weak bark or soft wood left on edge

46
New cards

Sap Streak

Line of sap left in wood

47
New cards

Pitch Pocket

Resin filled openings in rings

48
New cards

Check (Split)

Rupture across rings

49
New cards

Warping

Caused by uneven drying or shrinkage

50
New cards

Bowing

Curvature along the length

51
New cards

Crooking

Curvature along the face

52
New cards

Cupping

Edges roll up

53
New cards

Twisting

Corner lifts

54
New cards

Specific Gravity of cell walls

~1.5

55
New cards

Dry density of wood

~20-45 lb/ft³

56
New cards

Thermal Conductivity of wood

Better than metal, worse than insulation

57
New cards

Modulus of Elasticity of wood

~1×10^6 psi - 2×10^6 psi, depends on species, MC, SG, grain direction

58
New cards

Plywood

Panel made from plies glued together. Expensive, used structurally

59
New cards

Oriented Strand Board (OSB)

Panel, used for floors

60
New cards

I-Joist

Two 2×4s or 2×6s + an OSB web

61
New cards

Glue Laminated Beam (GLULAM)

Parallel grain glued together, used decoratively

62
New cards

Dead Load

Weight of the structure itself

63
New cards

Live Load

Occupants: furniture, people, removable items

64
New cards

PSF to PLF

Multiply the psf load by the tributary width

65
New cards

Tributary Width

Portion of floor supported by one beam: half of beam spacing on each side of the beam

66
New cards

Bending moment equation

M=((distributed load)*(span of beam)²)/8

67
New cards

Allowable bending stress

Found by table and adjusted by factors (fb,allow)

68
New cards

Actual bending stress

fb=Mc/I or M/S,

M is the bending moment

S is from the chosen beam size

69
New cards

Relationship between allowable and actual bending stress

Actual<allowable, this will determine the size of beam used

70
New cards

Mortar makeup

Water, aggregate, cement

71
New cards

Mortar uses

Goes inbetween units

  • bonds units

  • creates a bed layer and level surface

  • aesthetic


72
New cards

Grout makeup

High slump concrete, aggregate, water, cement

73
New cards

Grout uses

Goes inside units

  • bonds units

  • bonds reinforcements to units

  • fills voids in CMUs

  • increases bearing area

  • increases fire resistance and overturning resistance


74
New cards

Mortar types from strongest to weakest

M, S, N, O

75
New cards

Type M Mortar lime and sand makeup

¼ part lime, 3.5 parts sand

76
New cards

Type M Mortar properties

Brittle, strongest, used for reinforcement

77
New cards

Type S Mortar lime and sand makeup

½ part lime, 4.5 parts sand

78
New cards

Type S Mortar properties

Typical mortar

79
New cards

Type N Mortar lime and sand makeup

1 part lime, 6 parts sand

80
New cards

Type N Mortar properties

Typical mortar

81
New cards

Type O Mortar properties

Fluid, weakest

82
New cards

Type O Mortar lime and sand makeup

2 parts lime, 9 parts sand

83
New cards

CMU

Concrete masonry unit

84
New cards

Types of CMUs

Solid, hollow, light, medium, heavy, load bearing, non load bearing

85
New cards

Properties of lightweight CMU

Higher thermal and sound resistance

86
New cards

Solid CMU area

XS area>75% total area

87
New cards

Hollow CMU area

XS area<75% total area

88
New cards

Specified dimension

Size of unit

89
New cards

Nominal dimension

Size of unit + half of mortar joint on each side

90
New cards

Prism test

Tests bricks by stacking with mortar, placing in bag, curing, and compression+tensile strength testing

91
New cards

IRA

Initial rate of absorption, measures how quickly a brick removes water from mortar

92
New cards

Unit Strength test

Brick strength is calculated with tables, is usually a lower value than prism test results

93
New cards

Course

Horizonal layer of masonry units

94
New cards

Wythe

Vertical layers of courses (a 1 brick deep wall)

95
New cards

Stretcher

Normal brick position

96
New cards

Rowlock

Stretcher turned on its side (perpendicular to stretcher)

97
New cards

Header

Rowlock flipped onto the thicker side (head facing front)

98
New cards

Soldier

Standing brick (vertical stretcher)

99
New cards

Bed Joint

Horizontal layer where bricks are laid

100
New cards

Head joint

Vertical layer between bricks