ALARA
As Low As Reasonably Achievable
Anode
The positive electrode in the x-ray tube. It is composed of a tungsten target that is embedded in the larger copper stem.
atom
basic unit of matter
Bremsstrahlung radiation
"Braking radiation." The sudden deceleration of electrons as they interact with highly positively charged nuclei.
Cathode
The negative electrode in the x-ray tube. Consists of a tungsten filament in a focusing cup made of molybdenum. The cathode supplies the electrons necessary to generate x-rays
Central ray
x-rays at the center of the beam
contrast
differences in degrees of blackness on an image
control panel
the portion of the x-ray unit that contains the master switch, the indicator light, the selector buttons, and the exposure button.
Density
The overall darkness or blackness of an image.
Dental Radiography
the process of recording images of the teeth and adjacent structures by exposure to x-radiation.
Digital imaging
A filmless method of capturing an image and displaying it by using an image receptor, an electronic signal, and a computer to process and store the image.
distortion
Change in the size of an image caused by incorrect vertical angulation
Dose (of radiation)
The amount of energy absorbed by tissues
Dosimeter
A device used to detect and measure an accumulated dosage of radiation
Electron
a negatively charged particle in the atom
Extension Arm
Flexible arm that is attached to the x-ray tubehead
Genetic effects
Effects of radiation that are passed on to future generations through genetic cells
image
film-based or digitally produced recordings of anatomic structures.
Image receptor
A recording medium for an image, normally film, phosphor storage plate (PSP), or a digital sensor.
Intensity
the total energy of the x-ray beam.
Ion
an electrically charged particle
Ionization
Process by which electrons are removed from atoms, causing the harmful effects of radiation in humans
Ionizing
Radiation that produces ionization, resulting in harmful effects
Kilovoltage
Highest voltage of x-ray tube used during an exposure
Latent
Time between exposure to ionizing radiation and appearance of symptoms
Lead apron
Device used to protect the reproductive and blood forming tissues from scatter radiation
magnification
The proportional enlargement of an image
Master switch, indicator light, selector buttons, exposure button
components of the control panel
matter
anything that occupies space and has form or shape.
Milliampere (MA)
1/1000 of an ampere; a unit of measurement used to describe the intensity of an electrical current.
Penumbra
The blurred or indistinct area that surrounds an image
Personal radiation monitoring badge
A device that measures exposure of personnel to ionizing radiation by measuring the intensity of visible light emitted from a crystal in the detector when heated. The intensity of light emitted is dependent upon the radiation exposure.
Photon
a minute (tiny) bundle of pure energy that has no weight or mass
primary beam
The most penetrating beam produced at the target of the anode
quality (of x-ray beam)
the mean energy or penetrating ability of the x-ray beam
Radiation
Forms of waves of energy emission through space or material
quantity (of x-ray beam)
The number of x-rays produced in the dental unit; the quantity of x-rays produced is controlled by milliamperage.
Radiology
The science or study of radiation as used in medicine
Radiograph
Image produced on photosensitive film by exposing the film to radiation and then processing it
Wilhelm Conrad Roentgen (1895)
Bavarian physicist, who discovered the x-ray in 1895.
What did Roentgen use to produce cathode rays?
Crookes tube (vacuum tube)
Otto Walkhoff
made the first dental radiograph
C. Edmund Kells
credited with the first practical use of radiographs in dentistry in 1896.
William D. Coolidge
electrical engineer who developed the first hot-cathode x-ray tube, a high vacuum tube that contained a tungsten filament.
nucleus
dense core of the atom composed of particles known as protons and neutrons
Braking Radiation
The primary kind of radiation produced int eh dental x-ray tubehead.
True
Electrons remain stable in their orbit around the nucleus until the radiograph photons collide with them.
True
The shorter the wavelength of the x-ray, the greater its energy.
Scatter radiation
a form of secondary radiation that occurs when an x-ray beam has been deflected from its path by interaction with matter.
secondary radiation
x-radiation that is created when the primary beam interacts with matter
sensor
A solid-state image receptor that contains a silicon chip with an electric circuit
sharpness
A measure of how well an image reproduces the fine details or outline of an object
Somatic effects
Effects of radiation that cause illness and are responsible for poor health (such as cancer, leukemia, and cataracts) but are not passed on to offspring.
Thyroid collar
a flexible lead shield that is placed securely around the neck
Tubehead
The part of the x-ray unit that contains the x-ray tube, the high-voltage and low-voltage transformers, and insulating oil.
tungsten target
A focal spot in the anode
X-radiation
High energy ionizing electromagnetic radiation
Frequency
The number of wavelengths that pass a given point in a certain amount of time. The shorter the wavelength the higher the frequency.
Collimator
restricts the size and shape of the beam
aluminum filter
The 0.5 mm thick sheet located inside the PID in the path of the x-ray beam that filters out the nonpenetrating, longer wavelength radiographs.
X-ray Tube
heart of the x-ray generating system. Has a vacuum environment that allows electrons to flow with minimum resistance between the cathode and anode.
PID
The open-ended lead-lined cylinder that extends from the opening of the metal housing. Available in 8, 12, or 16 in. Longer cone is more effective.
focusing cup
keeps electrons suspended in an electron cloud at the cathode.
True
When the circuit button is pressed, the circuit within the tubehead is completed, and electrons rapidly cross from the cathode to strike the anode.
True
MA controls the number of electrons produced and increases the quantity of electrons available for the production of x-rays.
True
Once the exposure button is pressed the electrons in the cloud are shot across the x-ray tube to the anode. The molybdenum cup in the cathode directs the electrons to the tungsten target in the anode.
Insulating oil
absorbs heat created by the production of x-rays. Less than 1% of the energy is converted to x-rays, with 99% lost as heat.
True
Scatter radiation is dangerous to both the patient and the operator. "6 ft rule"
Radiopaque
white or light; structures that radiation does not easily pass through
enamel, denses areas of bone, and metal restorations
Radiolucent
Dark or black; structures that radiation can easily pass through.
air spaces, soft tissues, abscesses, tooth decay, and dental pulp
85 to 100 KV
produces more penetrating dental x-rays with more energy and shorter wavelengths
65 to 75 KV
Produces less penetrating dental x-rays with less energy and longer wavelengths.
True
a change in kP (kilovoltage peak) results in a change in the density of a dental radiograph.
7 to 15 mA
recommended mA setting in dental radiography
Intensity
the combination of the number of x-ray photons (quantity), and the energy of each photon (quality). Affected by kP, mA, exposure time, and distance.
kV
Higher __ produces more penetrating radiographs.
acute radiation exposure
occurs when a large dose of radiation is absorbed in a short time, such as in a nuclear accident
chronic radiation exposure
Occurs when small amounts of radiation are absorbed repeatedly over a long period
critical organs of radiation exposure
Skin, thyroid gland, lens of the eye, and bone marrow.
MPD (maximum permissible dose)
the current MPD for persons occupationally exposed to radiation is 5.0 rems/year. Non occupationally exposed persons is 0.1 rem/year.
70 kV
A setting of around _______keeps patient exposure at a minimum.
automatic processor
Machine that automates all film processing steps
Beam alignment device
assists in the positioning of the position indicator device (PID)
bitewing
Image view that shows the crowns of both arches on one film
Calcium tungstate
common type of phosphor
cassette
Contains extraoral films during exposure
cephalometric film
Shows the bony and soft tissue areas of the facial profile
charge-coupled device (CCD)
A solid-state image sensor used in intraoral digital imaging
digital image
Electronic signals captured by sensors and displayed on computer monitors
digitize
Scanning of traditional film-based radiographs into a digital image
duplicating film
Film designed for use in film duplicating machines
emulsion
a coating on the x-ray film that contains energy-sensitive crystals.
extraoral film
film designed for use in cassettes
film speed
The sensitivity of the emulsion on the film to radiation
intensifying screen
The part inside an extraoral cassette that converts x-ray energy into visible light, which in turn exposes screen film.
intraoral film
Film designed for placement in the patients mouth
label side
Colored side of the film that faces the tongue
latent image
the invisible image o the x-ray film after exposure but before processing.
occlusal
Radiographic view that shows large areas of the maxilla or mandible
panoramic film
Used in cassettes to provide a wide view of both the upper and lower jaws