Pathogen Identification

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/11

encourage image

There's no tags or description

Looks like no tags are added yet.

12 Terms

1
New cards
What are the three main categories of diagnostic tests used to identify microbial pathogens in clinical samples?
When a physician suspects an infectious disease, likely infection sites (blood, urine, feces, sputum, cerebrospinal fluid, or pus) are sampled and tested using one or more of three assay types (Figure 29.4): (1) Microbiological tests (growth-dependent enrichment, selective/differential media, isolation of pure culture), (2) Immunological tests (detecting antibodies or microbial/viral antigens via agglutination, immunofluorescence, enzyme immunoassay [EIA], rapid tests, immunoblots), and (3) Nucleic acid tests (molecular assays searching for pathogen DNA/RNA genes by amplification/hybridization).
2
New cards
Define Specificity and Sensitivity in diagnostic testing, and explain what each minimizes.
Specificity is the ability of a test to recognize ONLY the target pathogen, thereby minimizing false positives. Sensitivity is the minimum amount of a pathogen required for detection (ability to detect true cases), thereby minimizing false negatives.
3
New cards
Using the COVID-19 rapid antigen test vs. Gold Standard PCR comparison table, give the formulas and values for Sensitivity and Specificity.
Data: 92 True Positives (TP), 49 False Negatives (FN), 1 False Positive (FP), 1,323 True Negatives (TN). Sensitivity = TP / (TP + FN) = 92 / (92 + 49) = 92 / 141 ≈ 0.65 (65%). Specificity = TN / (FP + TN) = 1323 / (1 + 1323) = 1323 / 1324 ≈ 0.999 (99.9%).
4
New cards
How is Neisseria gonorrhoeae diagnosed by culture, and what four antimicrobial agents are included in Thayer-Martin selective agar?
N. gonorrhoeae is diagnosed by culture on Thayer-Martin agar, a selective medium that supplies essential nutrients for N. gonorrhoeae growth while inhibiting normal commensals using four drugs: (1) Vancomycin (inhibits Gram-positive bacteria), (2) Colistin (inhibits Gram-negative bacilli), (3) Nystatin (inhibits fungi), and (4) Trimethoprim (inhibits swarming Proteus species).
5
New cards
Compare Selective Media vs. Differential Media.
Selective media allow some organisms to grow while inhibiting others (e.g., via toxic dyes or antibiotics). Differential media allow identification and distinction of organisms based on their growth characteristics and colony appearance (e.g., color changes from metabolic reactions) on the medium.
6
New cards
Explain why Eosin-Methylene Blue (EMB) agar is both selective and differential.
EMB agar is selective because its dyes are toxic to Gram-positive bacteria, inhibiting their growth while allowing Gram-negative bacteria to grow. It is differential because it distinguishes lactose fermenters (like E. coli) from non-lactose fermenters (like P. aeruginosa): lactose fermentation produces acid, lowering the pH and causing the dyes to precipitate into dark, purplish or blue-black colonies.
7
New cards
What are Immunological Assays (Immunoassays), and what six types are listed in Lecture 32?
Immunoassays use antibodies specific for pathogens or their products for in vitro tests designed to detect specific infectious agents. Six types listed: Precipitation, Agglutination, Immunofluorescence, Enzyme Immunoassays (EIAs/ELISAs), Rapid Tests, and Immunoblots (with Immunofluorescence, EIAs, and Rapid Tests covered in detail).
8
New cards
Compare Direct Immunofluorescence vs. Indirect Immunofluorescence (Figure 29.17).
Direct immunofluorescence: A fluorescent dye is covalently linked directly to the primary antibacterial antibody that binds the bacterial cell antigen. Indirect immunofluorescence: An unlabeled primary antibody (e.g., made in a rabbit) binds the bacterial antigen, and then a fluorescently labeled secondary antibody (e.g., anti-rabbit antibody) binds to the primary antibody for detection.
9
New cards
How do Enzyme Immunoassays (EIAs / ELISAs) work, and what is the difference between Direct EIA and Indirect EIA?
EIAs use kit-supplied antibodies or antigens linked to an enzyme (E) that catalyzes a color-developing reaction proportional to the target bound on a solid-phase support; they are very sensitive and widely used. Direct EIA detects microbial/viral antigen from a patient sample (captured between kit antibodies, with enzyme-linked antibody producing color). Indirect EIA detects patient antibodies against a pathogen (patient antibodies bind kit-supplied antigen on the solid support, and enzyme-linked anti-human antibody produces color).
10
New cards
How do lateral-flow Rapid Tests (e.g., BinaxNOW RSV, Strep A, SARS-CoV-2 antigen tests) work, and what do the Test line and Control line contain?
Similar to EIA but delivering results within minutes (though generally less sensitive): the patient specimen flows from the sample well through a matrix containing antibodies conjugated to a colored molecule (chromophore). The Test line consists of immobilized antibodies that capture the target antigen (forming a colored sandwich if positive). The Control line consists of immobilized antibodies that bind the chromophore-conjugated antibodies directly to confirm the test strip worked properly.
11
New cards
What do Nucleic Acid-Based Assays detect, and what are the four types listed in Lecture 32?
Nucleic acid-based assays detect specific DNA or RNA sequences unique to pathogens. Four types: (1) Nucleic acid hybridization, (2) Reverse transcriptase PCR (RT-PCR, which reverse-transcribes viral/pathogen RNA into complementary DNA before performing PCR), (3) Quantitative real-time PCR (qPCR), and (4) Qualitative PCR.
12
New cards
How does Quantitative Real-Time PCR (qPCR) work, and how do amplification curves (Sample A vs. Sample B in Figure 29.24) reflect starting pathogen load?
In qPCR, PCR products increase exponentially with each amplification cycle (detected via relative fluorescence intensity) until reagents (primers and nucleotides) run out and the curve plateaus. Samples with MORE starting pathogen genomes (Sample A, e.g., 64 -> 128) cross the detectable fluorescence threshold in FEWER cycles (~10–15 cycles) than samples with FEWER starting genomes (Sample B, e.g., 8 -> 16 -> 32 -> 64 -> 128, crossing around ~20 cycles).