Power supply for EBOP
121X
Power supply for TGOP
136Y-3
Power supply for MSP
136Y-3 and 132A-1
Power supply for AOP
131A
Power supply for Vapor extractor
131A-2
Power supply for Conditioner transfer pump
131A-2
Power supply for Conditioner circulating pump
132B-1
CRD Hydralics
Provides injection flow to the RR seals to keep them cool and clean
RBCCW
Provides water to the RR system to provide cooling for: motor windings, bearings, seals
Containment Ventilation
Cooling to the RR motor
Reactor Protection systems
RPS logic feeds trip signals to EOC-RPT
Drywell Equipment Drain Pump
Input from seal staging line RR pump seals
Reactor recirculation flow control
Provides hydraulic positioning and signals for the RR Flow control valves