1/73
Comprehensive vocabulary flashcards covering radiographic terminology, procedures, imaging physics, cellular radiobiology, and radiation safety principles.
Radiography
One of the primary diagnostic methods used to detect and diagnose disease by creating images of the patient's internal anatomic structures.
Adult Human Skeleton
The framework of the mature human body, consisting of exactly 206 bones.
Anatomical Position
The standard reference position of the human body used by radiographers as a baseline for positioning terms and descriptions.
Supine
A patient positioning term describing an individual lying flat on their back.
Prone
A patient positioning term describing an individual lying flat on their abdomen.
Radiographic Projection
The path or direction that the x-ray beam takes as it passes through the body from entrance to exit.
Anatomical Markers
Lead markers placed on the image receptor to identify the correct right and left sides of the patient on a radiograph.
Floating Table
A specialized radiographic examination table designed to move freely in all directions for easy patient centering.
External Preparation
The removal of external radiopaque items such as clothing and jewelry covering the body area through which x-rays must pass.
Internal Preparation
Preparation methods such as cleansing enemas performed before abdominal examinations to ensure structures are not obstructed by gas and fecal material.
First Digit
The anatomical designation for the thumb of the hand.
Dorsal Spine
An alternate clinical term used to describe the thoracic spine.
Chest Radiograph SID
The standard source-to-image receptor distance required for a general chest radiograph, which is 72 inches.
Abdomen Radiograph SID
The standard source-to-image receptor distance required for an abdominal radiograph, which is 40 inches.
Chest Radiograph Breathing Instructions
The respiratory instruction where the patient is asked to hold their breath upon the second full inspiration to ensure maximum lung expansion.
Extremity Radiography Rule
The standard imaging rule requiring a minimum of two projections taken at right angles (90∘) to each other due to the risk of fractures, sprains, or dislocations.
Scoliosis Series
A specialized radiographic examination of the spinal column performed to evaluate lateral curvature.
Panoramic Tomography
A radiographic imaging technique used primarily to examine the mandible and temporomandibular joints (TMJs).
Anode
The positive electrode in the x-ray tube, containing the target where high-speed electrons strike to produce x-rays.
Cathode
The negative electrode in the x-ray tube that serves as the source of electrons.
Focal Spot
The specific area of the anode target from which x-ray photons emanate.
kVp (Peak Kilovoltage)
An exposure factor that controls the quality and penetrating ability of the x-ray beam.
mAs (Milliampere-Seconds)
An exposure factor that controls the total quantity or number of x-ray photons produced in the x-ray tube.
Collimator
A box-like device attached below the x-ray tube housing equipped with adjustable lead shutters that restrict the primary x-ray beam to a defined field size.
Primary Radiation
The stream of x-ray photons that emerges directly from the port of the x-ray tube housing.
Remnant Beam
The radiation that exits the patient and reaches the image receptor, consisting of image-forming primary photons and scattered radiation.
Scatter Radiation
X-ray photons produced within the patient that change trajectory and diverge from the primary path, representing the single largest source of occupational exposure.
SID (Source-to-Image Receptor Distance)
The total linear distance measured from the focal spot on the x-ray tube anode to the surface of the image receptor.
OID (Object-to-Image Receptor Distance)
The distance between the anatomical part being radiographed and the surface of the image receptor.
Distortion
The misrepresentation of the true size or true shape of the anatomical object on the recorded radiographic image.
Contrast
The perceptible difference in brightness or optical density between adjacent anatomical areas within a radiographic image.
Image Brightness
The intensity or measurement of visible light emitted from the display monitor presenting the digital radiograph.
Artifact
Any unwanted, artificial density or foreign blemish appearing on a finished radiograph, such as jewelry, zippers, or tattoos.
Computed Radiography (CR)
A cassette-based digital imaging system that utilizes a photostimulable phosphor imaging plate to capture latent images.
Radiographic Grid
A device placed between the patient and the image receptor to absorb scattered photons before they degrade image contrast, inherently increasing patient dose.
Fluoroscopy
A dynamic, real-time radiographic modality used by radiologists to evaluate functional physiological motion inside the body.
Contrast Media
Diagnostic substances (solutions, suspensions, or gases) administered to temporarily enhance visualization and contrast between adjacent soft tissue structures.
Barium Sulfate
A chemically inert, insoluble positive contrast suspension used routinely for gastrointestinal evaluations that cannot be absorbed by the body.
Esophagram
A dynamic radiographic examination of the pharynx and esophagus performed while the patient ingests a thick barium sulfate paste.
Barium Enema
A fluoroscopic and radiographic examination of the large intestine involving retrograde rectal administration of barium sulfate, often paired with air.
Angiogram
A specialized radiographic vascular procedure that utilizes an iodinated contrast medium to evaluate arteries.
Arthrogram
A contrast study of a synovial joint cavity (frequently the shoulder or knee) often performed in conjunction with CT or MRI.
Myelography
A radiographic study of the spinal cord's subarachnoid space using contrast media, frequently paired with CT or MRI.
Hysterosalpingography
A specialized radiographic study of the uterine cavity and fallopian tubes using an iodinated contrast medium.
Mammogram
A specialized low-dose radiographic image of the breast tissue.
Excretory Urography
A diagnostic radiographic examination of the urinary tract (kidneys, ureters, and bladder) using intravenously injected iodinated contrast.
Voiding Cystourethrogram (VCUG)
A dynamic contrast evaluation of the urinary bladder and urethra performed while the patient is voiding to evaluate urination function.
ERCP (Endoscopic Retrograde Cholangiopancreatography)
A combined endoscopic and radiographic procedure utilized to diagnose conditions and anomalies of the biliary system and pancreatic ducts.
Cardinal Principles of Radiation Protection
The three core safety rules used to minimize radiation exposure: minimizing Time, maximizing Distance, and utilizing Shielding.
ALARA
The fundamental radiation protection philosophy ensuring that all occupational and medical exposures are kept 'As Low As Reasonably Achievable'.
No-Threshold Concept
The radiation protection premise postulating that any dose of ionizing radiation, no matter how small, has the potential to induce adverse biological effects.
Inverse Square Law
The physical principle establishing that radiation intensity is inversely proportional to the square of the distance from the radiation source.
Shielded Control Booth
The safest barrier location for the radiologic technologist to stand behind during exposures in a general diagnostic x-ray suite.
Portable X-Ray Exposure Cord Length
The protective requirement dictating that the exposure switch cord on a mobile radiographic unit must measure at least 6 feet.
Total Diagnostic Filtration
The radiation safety requirement mandating a minimum of 2.5 mm aluminum equivalent filtration for diagnostic units operating above 70 kVp.
Dosimetry
The scientific discipline and practice concerning the detection and quantitative measurement of absorbed radiation dose.
Personnel Dosimeters (OSL & TLD)
Highly accurate monitoring devices—such as Optically Stimulated Luminescent dosimeters and Thermoluminescent dosimeters—exchanged monthly or quarterly.
Occupational Whole Body Dose Limit
The annual effective radiation dose limit for radiation workers, established at 50 mSv per year.
Public Dose Limits (Frequent vs. Infrequent)
The established annual dose limits for the general public, set at 1 mSv for frequent exposure and 5 mSv for infrequent exposure.
Embryo-Fetus Dose Limits
The maximum permissible dose equivalent for a declared pregnant worker, established as 5.0 mSv for the entire gestation and not exceeding 0.5 mSv per month.
Air Kerma
The SI unit representing the amount of energy deposited or ionization generated per unit mass of dry air.
Gray (Gy)
The standard SI unit representing the amount of radiation energy absorbed by any irradiated matter or biological medium.
Photoelectric Effect
An interaction where an incident x-ray photon ejects an inner-shell orbital electron and transfers all of its energy, causing the incident photon to completely disappear.
Compton Scattering
An interaction where an incident x-ray photon collides with an outer-shell orbital electron, losing only part of its energy and scattering in a new direction.
Coherent Scattering
An interaction in which a low-energy incident photon changes trajectory without transferring energy or causing ionization.
Mitosis
The process of somatic cell division in which a single parent cell divides to produce two identical daughter cells.
Direct Hit Theory
The radiobiological model stating that ionizing radiation interacts directly with critical target molecules (DNA), damaging chromosomes and leading to cell death or mutation.
Law of Bergonie and Tribondeau
The radiobiological law stating that cells exhibiting high mitotic rates, rapid division, and low differentiation are the most radiosensitive.
Lymphocytes
Mature white blood cells that represent the most radiosensitive cell population in the human body.
Nerve Cells
Highly specialized, non-dividing mature cells that represent the least radiosensitive cells in the human body.
Latent Period
The time interval that elapses between the initial absorption of radiation and the initial manifestation of detectable biological damage.
Acute Radiation Syndrome (ARS)
A rapid systemic biological response caused by a very large dose of whole-body radiation delivered over a very short duration.
Erythema
Radiation-induced abnormal redness of the skin caused by high localized exposure doses.
Radioactive Half-Life
The period of time required for the initial activity of a radioactive nuclide to disintegrate to exactly one-half of its original value.