CM 313: Construction Methods & Materials - Waterproofing, Enclosures, Openings & Masonry

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/64

flashcard set

Earn XP

Description and Tags

Comprehensive vocabulary flashcards covering subgrade waterproofing, joint sealants, firestopping, commercial roofing systems, door assemblies, exterior glazing systems, and masonry construction based on the CM 313 Quiz #2 study guide.

65 Terms

1
New cards

Waterproofing Pre-applied

Waterproofing membrane that is installed prior to the construction of the foundation wall, against which concrete is subsequently placed.

2
New cards

Waterproofing Post-applied

Waterproofing membrane applied directly to a previously constructed and properly cured foundation system.

3
New cards

Positive Side Waterproofing

a) Protects concrete foundation wall from water and corrosive elements in

soil/groundwater.

b) Not influenced by hydrostatic pressure.

c) Not accessible for repair/inspection

d) Membrane Types

4
New cards

Waterproofing Membrane Types - Sheet Based

• Post-applied - 1.5mm thick rubberized asphalt sheet laminated to high

density polyethylene film. “Peel and stick” installation method.

• Pre-applied – A flexible thermoplastic sheet that is either coated with

reactive adhesive that is activated by the heat of hydration or embedded

with expansive clay (bentonite) which swells when in contact with

water, both of which will permanently bond to the concrete.

5
New cards

Pre-applied Sheet Waterproofing Membrane

A flexible thermoplastic sheet that permanently bonds to concrete, coated either with a reactive adhesive activated by the heat of hydration or embedded with expansive clay (bentonite) that swells upon water contact.

6
New cards

Waterproofing Membrane Types - Fluid Applied

ii. Fluid Applied

• Installation methods

o Sprayed

o Brushed

o Rolled

• Monolithic membrane without seams

• Easily applied to geometrically complex and/or small areas

• Less detail work, thus reduced difficulty waterproofing intricate

conditions

• Less dependent upon substrate conditions. Greater ability to

waterproof areas with surface irregularities.

• Thickness is dependent upon installer. Multiple coats/passes may be

required. Difficult to determine proper film thickness is achieved on

rough substrate.

7
New cards

Negative Side - Waterproofing

a) Concrete foundation wall is exposed to water and corrosive elements in

soil/groundwater.

b) Must resist hydrostatic pressure through cracks in concrete.

c) Visible and accessible for repair/inspection.

d) System types

8
New cards

System Types - Waterproofing

Crystalline Compound

Injectable chemical grout

9
New cards

Crystalline Compound

Brush applied to extensive areas, the compound combines with water and the byproducts of cement hydration to form non-soluble crystalline structure that fill the voids in the concrete, thus rendering it impenetrable by water.

10
New cards

Injectable Chemical Grout

A non-viscous hydrophobic material that can be injected into cracks. Upon reacting with water, the grout expands and forms a seal within the crack.

11
New cards

Bathtub Configuration

a) Not reliant on mechanical systems to keep building dry.

b) Water is not allowed to enter structure.

c) Weight of building/tie-downs must resist uplift force of hydrostatic pressure.

d) Mat foundation system is expensive.

12
New cards

Drained/Pumped Configuration

a) Dependent on permanent pumping system.

b) Exposure to sewage discharge fees.

c) Water is brought into building, directed to sumps and pump discharged.

d) Efficient foundation system.

13
New cards

Waterstop - Waterproofing Accessories

applied at concrete cold joints

a) Bentonite: rectangular cross section, post applied

b) PVC: Dumbbell cross section, cast-in-place

c) Reinjectable: Tube cast-in-place used to inject and reinject chemical grout

14
New cards

Drainboard - Waterproofing Accessories

High density polyethylene sheet heat molded to have dimpled protrusions, with a non-woven filter fabric bonded to the face.

a) Provides a drainage path to relieve substrate from hydrostatic pressure.

b) Provides physical protection of waterproofing membrane from both

abrasion/impact damage and UV degradation.

15
New cards

Drain Tile Pipe - Waterproofing Accessories

Rigid or flexible perforated plastic pipe which relieves hydrostatic pressure by providing a pathway to drain groundwater away from structure. Also provides a path for subsoil drainage to pumped discharge location.

16
New cards

Materials - Joint Sealants

1) Silicone – UV resistant often used within window and glazing systems and between window systems and adjacent façade materials.

2) Polyurethane – Durable and highly elastic used within masonry, cast-in-place concrete, and exterior site improvements (sidewalks, concrete paving, pavers, etc.) capable of withstanding significant movement.

3) Acrylic Latex – Paintable indoor and general purpose exterior locations

17
New cards

Polyurethane Sealant

A durable, highly elastic joint sealant capable of accommodating significant movement, used within masonry, cast-in-place concrete, and exterior site improvements such as sidewalks and concrete paving.

18
New cards

Acrylic Latex Sealant

A paintable joint sealant formulated for indoor applications and general-purpose exterior locations.

19
New cards

Firestopping

Fire resistant materials that seal openings between slab edges and façade, penetrations in fire rate walls and floors for pipe, duct and cable.

20
New cards

Mineral Wool - Firestopping Materials

1) Mineral Wool – high temperature resistant insulation formed by spinning molten mineral or rock materials such as slag and ceramics.

a. Non-combustible

b. Moisture resistant

c. Typically used to fill larger openings in fire rated assemblies

d. Often used in conjunction with fire rated sealant or smoke seal

21
New cards

Intumescent Sealant - Firestopping Materials

Intumescent Sealant – caulk and putty that rapidly expands when exposed to heat, sealing voids in openings in fire rated floors and walls.

a) Non-combustible

b) Rapid response to heat @ 400oF – 500oF

c) Expands to 5-10 times original volume

22
New cards

Membrane - Roofing

Membrane – Single ply sheet goods seamed with heat or solvent based adhesive

1) System Characteristics

a) Relatively thin and without redundancy; therefore, easily damaged with a likely resultant leak.

b) Insulation is located below the membrane and above the substrate.

c) Seams are potential weak spots.

23
New cards

Installation Method - Membrane Roofing

2) Installation Method

a) Fully Adhered: Adhesive uniformly applied to substrate in a manner that completely attaches the membrane. Consistent application and timing of reaction/curing of adhesive are critical quality control aspects of installation procedure

b) Mechanically Fastened: Membrane is attached at edges to substrate with screws and washers. Subsequent sheets are lapped at the edges to cover the fasteners and then heat welded or chemically adhered together.

c) Ballasted: Loose laid sheets heat welded or chemically adhered together and held down with stone ballast and/or concrete pavers.

24
New cards

Fully Adhered

Fully Adhered: Adhesive uniformly applied to substrate in a manner that completely attaches the membrane. Consistent application and timing of reaction/curing of adhesive are critical quality control aspects of installation procedure

25
New cards

Mechanically Fastened

Mechanically Fastened: Membrane is attached at edges to substrate with screws and washers. Subsequent sheets are lapped at the edges to cover the fasteners and then heat welded or chemically adhered together.

26
New cards

Ballasted

Ballasted: Loose laid sheets heat welded or chemically adhered together and held down with stone ballast and/or concrete pavers.

27
New cards

Hot Applied Modified Bituminous - Roofing

Rubberized asphalt installed hot with a fiberglass reinforcing membrane embedded between layers, and topped by an asphalt coated protection sheet.

1) System characteristics

a) Fully bonded to substrate.

b) Monolithic membrane without exposure of seams

c) Dependent upon installer for proper thickness.

d) Insulation is above membrane and anchored by ballast

28
New cards

Built-up Bituminous - Roofing

Modified hot asphalt, layered with bituminous reinforcing sheets (roofing felts).

1) System characteristics

a) Fully adhered system.

b) Plies (reinforcing layers) provides redundancy and resistance to abrasion or other physical damage.

c) Insulation is below roofing system and is mechanically attached to substrate.

29
New cards

Hollow Metal - Openings: Doors, frames & hardware; Interior glass & glazing

Hollow Metal: Steel sheets cut and bent into doors and door frames commonly used in Commercial, Institutional & Industrial buildings


1) Frames

a) Welded

i. Jambs and Head welded together and shipped as a complete unit with a spreader @ the sill for temporary bracing.

ii. Installed before masonry wall or during wall stud framing

iii. Seamless corners


b) Knock down (KD)

i. Jambs and head shipped as individual units

ii. Installed after wall completed

iii. Noticeable seam @ corners

iv. Retrofit new openings in existing walls

30
New cards

Doors - Hollow Metal Openings: Doors, frames & hardware; Interior glass & glazing

Hollow Metal: Steel sheets cut and bent into doors and door frames commonly used in Commercial, Institutional & Industrial buildings

2) Doors

a) Characteristics

i. Durable

ii. Easily repaired and painted

31
New cards

Wood - Openings: Doors, frames & hardware; Interior glass & glazing

1) Doors

2) Characteristics

a) Available in wide range of species and color

b) Repairs are difficult with stain grade – easier with paint grade

32
New cards

Borrowed Lites

Interior non-operable glazed openings associated with a door opening

1) Door – an opening in the door leaf

2) Sidelite – opening adjacent to door frame jamb

3) Transom – opening above the door frame head

33
New cards

Sidelite

Sidelite – opening adjacent to door frame jamb

34
New cards

Transom

Transom – opening above the door frame head

35
New cards

Punched Windows - Exterior Windows System Types

a) A window located within a single opening in a solid surface façade systems.

b) A single unit window, wherein the sash can be fixed or operable.

36
New cards

Strip (ribbon) Windows - Exterior Windows System Types

a) Window units placed side by side to form a continuous horizontal band

b) Typically sashes are fixed, although an operable sash can be incorporated into the series of units.

37
New cards

Window Wall - Exterior Windows System Types

a) Located between adjacent floor slabs and supported by bearing on the slabs.

b) Often used in residential applications as they allow for more flexibility for configuration of operable windows and balcony doors.

c) More susceptible to performance failure (leaks) than curtainwall due to increased number of flashing details at multitude of window system to slab interface.

38
New cards

Store Front - Exterior Windows System Types

a) Typically a window wall system located on the ground floor (or street level) of a building, and including doors to accommodate retail use and/or the building entrances/egress.

39
New cards

Curtainwall - Exterior Windows System Types

A window system located outside the plane of the structure and supported by the slab edges.


b) Stick built

i. Vertical and horizontal mullions are delivered as individual fabricated

members.

ii. Vertical mullions are attached to the building, spanning from slab edge to slab edge.

iii. Horizontal mullions are then attached to the vertical members.

iv. Glass is field glazed into assembled mullions.


c) Unitized

i. Shop assembled and glazed units that span vertically one or two floors.

ii. Unit stacks on top of unit below with interfacing horizontal member being a split mullion.

iii. Unit horizontally adjoins adjacent unit with interfacing vertical member being a split mullion.

40
New cards

Storefront

A ground-floor or street-level window wall system incorporating entrance doors to accommodate retail use and building ingress/egress.

41
New cards

Curtainwall

An exterior window system positioned completely outside the plane of the structural frame and supported structurally by slab edges.

42
New cards

Stick Built Curtainwall

A curtainwall system where vertical and horizontal mullions are delivered as individual fabricated components, attached slab-to-slab on-site, and field glazed.

43
New cards

Unitized Curtainwall

A curtainwall system consisting of shop-assembled and shop-glazed panels spanning one or two stories that interlock on-site with split mullions at horizontal and vertical interfaces.

44
New cards

Float Glass - Exterior Windows

Ordinary glass that has been annealed to relieve internal stresses.

45
New cards

Heat Strengthened Glass - Exterior Windows

Thermally strengthened to be twice as strong as annealed float

glass. Not considered safety glass.

46
New cards

Tempered Glass - Exterior Windows

Strengthened to 4-5 times that of float by thermal or chemical process. Fractures into small relatively harmless pieces. Prone to spontaneous breakage

47
New cards

Laminated Glass - Exterior Windows

Two or more glass layers bonded together with a plastic interlayer. Breaks

in a spiderweb pattern held together by the interlayer.

48
New cards

Spandrel Glass - Exterior Windows

Opaque glass system typically placed on the portion of the façade that

fronts floor slabs, ceiling and floor plenums, and other structure.

49
New cards

Concrete Masonry Unit (CMU) - Masonry & Architectural Precast Concrete

Manufactured kiln dried cast concrete modular units

a) Common size: 8” high X 16” long.

b) Common widths: 4”, 6”, 8” & 12”.

c) Common finishes

i. Gray – As cast finish

ii. Split Face – Cast in pairs and then split into two units

iii. Ground Face – Gray block with exposed surfaces ground and polished

iv. Glazed – Gray block faced with a thin ceramic section

d) Structural Reinforcing

i. Vertical – Rebar installed in grouted cells at specified spacing

ii. Horizontal – Wire ladders in bed joints at specified coursing

50
New cards

Gray

Gray – As cast finish

51
New cards

Split Face

Split Face – Cast in pairs and then split into two units

52
New cards

Ground Face

Ground Face – Gray block with exposed surfaces ground and polished

53
New cards

Glazed

Glazed – Gray block faced with a thin ceramic section

54
New cards

Split Face CMU - Masonry & Architectural Precast Concrete

Brick – manufactured kiln dried shaped clay modular units

a) Range of available sizes

b) Wide range of available colors and surface finishes

c) Special shapes

i. Corners – other than 90o

ii. Curved – non-segmented radius

iii. Lipped – conceal horizontal leg(s) of lintel

d) Installation Patterns

i. Running

ii. Stack

iii. Flemish


55
New cards

Stone - Masonry & Architectural Precast Concrete

Quarried natural material cut into modular units

a) Extensive Range of Colors

b) Range of available surface finishes

i. Honed – Smooth matte surface with little to no sheen

ii. Sandblasted – Textured finish without sheen

iii. Bush Hammered – Heavily textured flat surface

iv. Polished – Smooth glossy, highly reflective surface

c) Available sizes constrained only by quarry limitations

d) Installed in a range of patterns

56
New cards

Honed

Honed – Smooth matte surface with little to no sheen

57
New cards

Sandblasted

Sandblasted – Textured finish without sheen

58
New cards

Bush Hammered

Bush Hammered – Heavily textured flat surface

59
New cards

Polished

Polished – Smooth glossy, highly reflective surface

60
New cards
term image

Running

61
New cards
term image

Stack

62
New cards
term image

Flemish

63
New cards

Vertical - Structural Reinforcing

Rebar installed in grouted cells at specified spacing

64
New cards

Horizontal - Structural Reinforcing

Wire ladders in bed joints at specified coursing

65
New cards

Difference between window wall and curtain wall

Curtain wall - supported by the slab edges, not sitting on it, but supported by the outside of it; at the very bottom has a seal, no seal and joint, all outside the building

Window Wall - shorter from deck to deck, seal and joint at the top and bottom, more elements so more likely to leak