1
New cards

What does ASHRAE Standard 34 classify?

Refrigerants according to toxicity and flammability.

2
New cards

What is ASHRAE Class A?

Lower toxicity.

3
New cards

What is ASHRAE Class B?

Higher toxicity.

4
New cards

What does Flammability Class 1 indicate?

No flame propagation.

5
New cards

What does Flammability Class 2L indicate?

Lower flammability with slow burning velocity.

6
New cards

What does Flammability Class 2 indicate?

Flammable.

7
New cards

What does Flammability Class 3 indicate?

Higher flammability.

8
New cards

What are examples of A1 refrigerants?

R-22, R-134a, and R-410A.

9
New cards

What are examples of A2L refrigerants?

R-32, R-454B, and R-1234yf.

10
New cards

What is an example of an A2 refrigerant?

R-152a.

11
New cards

What are examples of A3 refrigerants?

R-290 and R-600a.

12
New cards

What is an example of a B1 refrigerant?

R-123.

13
New cards

What is an example of a B2L refrigerant?

R-717 ammonia.

14
New cards

What is R-290?

Propane.

15
New cards

What is R-600a?

Isobutane.

16
New cards

What is R-717?

Ammonia.

17
New cards

What is R-744?

Carbon dioxide.

18
New cards

What is the maximum burning velocity for A2L refrigerants?

10 cm/s.

19
New cards

What is the heat of combustion criterion for A2L refrigerants?

Below 8,169 BTU/lb.

20
New cards

What does GWP stand for?

Global warming potential.

21
New cards

What does ODP stand for?

Ozone depletion potential.

22
New cards

What is the reference GWP of carbon dioxide?

1.

23
New cards

What is the GWP of R-410A?

2088.

24
New cards

What is the GWP of R-404A?

3920.

25
New cards

What is the GWP of R-32?

675.

26
New cards

What is the GWP of R-290?

3.

27
New cards

What is the GWP of R-600a?

3.

28
New cards

What is the GWP of R-1234yf?

Less than 1.

29
New cards

Which refrigerant families contain chlorine?

CFCs and HCFCs.

30
New cards

What does HFC stand for?

Hydrofluorocarbon.

31
New cards

What does HFO stand for?

Hydrofluoroolefin.

32
New cards

What do hydrocarbon refrigerants contain?

Hydrogen and carbon.

33
New cards

Does low GWP mean low flammability?

No.

34
New cards

What is the function of a compressor?

Compresses low-pressure vapor into high-pressure, high-temperature vapor.

35
New cards

What is the function of a condenser?

Rejects heat and condenses refrigerant vapor into liquid.

36
New cards

What does a metering device do?

Reduces refrigerant pressure and regulates flow into the evaporator.

37
New cards

What is the function of an evaporator?

Absorbs heat and boils liquid refrigerant into vapor.

38
New cards

What does a filter drier do?

Removes moisture and particulate contamination.

39
New cards

What is the function of a receiver?

Stores liquid refrigerant as operating load changes.

40
New cards

What does an accumulator do?

Prevents liquid refrigerant from entering the compressor.

41
New cards

Where is the accumulator located?

Suction line before the compressor.

42
New cards

What are examples of fixed metering devices?

Pistons and capillary tubes.

43
New cards

What are examples of adjustable metering devices?

TXVs, EEVs, and AEVs.

44
New cards

What is sensible heat?

Heat that changes temperature without changing state.

45
New cards

What is latent heat?

Heat associated with a change of state.

46
New cards

What is saturation?

Condition in which liquid and vapor coexist.

47
New cards

What does a pressure-temperature chart do?

Converts refrigerant pressure to its corresponding saturation temperature.

48
New cards

What is the superheat formula?

Actual vapor-line temperature minus low-side saturation temperature.

49
New cards

What is the subcooling formula?

High-side saturation temperature minus actual liquid-line temperature.

50
New cards

What is the superheat example for a 58°F line and 51°F saturation?

7°F.

51
New cards

What is the subcooling example for a 114°F saturation and 100°F line?

14°F.

52
New cards

What is an azeotropic blend?

A blend that behaves like a single-compound refrigerant.

53
New cards

What series is the azeotropic refrigerant?

500 series.

54
New cards

What is a zeotropic blend?

A refrigerant blend that can fractionate and exhibits temperature glide.

55
New cards

What series is the zeotropic refrigerant?

400 series.

56
New cards

What is a near-azeotropic blend?

A zeotropic blend with very little temperature glide.

57
New cards

What is fractionation?

Separation of blend components at different rates, changing refrigerant composition.

58
New cards

What is temperature glide?

Difference between bubble-point and dew-point temperatures at the same pressure.

59
New cards

What is the bubble point?

Saturated-liquid temperature.

60
New cards

What is the dew point?

Saturated-vapor temperature.

61
New cards

Which point is used for superheat?

Dew point.

62
New cards

Which point is used for subcooling?

Bubble point.

63
New cards

How are zeotropic blends withdrawn from a cylinder?

As liquid to prevent fractionation.

64
New cards

How may azeotropic blends be charged?

As liquid or vapor.

65
New cards

What is the temperature glide of R-410A?

Approximately 0.3°F.

66
New cards

What is a binary blend?

Contains two refrigerant components.

67
New cards

What is a ternary blend?

Contains three refrigerant components.

68
New cards

What is the evaporator midpoint formula?

(Bubble temperature × 0.40) + (Dew temperature × 0.60).

69
New cards

What is the condenser midpoint formula?

(Dew temperature + Bubble temperature) ÷ 2.

70
New cards

What is the standard comfort-cooling airflow?

400 CFM per ton.

71
New cards

What is the high-humidity airflow?

325-350 CFM per ton.

72
New cards

What is the high sensible-load airflow?

425-450 CFM per ton.

73
New cards

What is the typical supply-to-return temperature split?

16-22°F.

74
New cards

What is the typical evaporator coil temperature?

40-45°F.

75
New cards

What is the effect of a dirty condenser?

Restricts airflow and reduces heat rejection.

76
New cards

What is mitigation in refrigerant management?

Measures that reduce the likelihood of refrigerant accumulation or ignition.

77
New cards

What does an active refrigerant sensor do?

Detects refrigerant leaks and may initiate mitigation controls.

78
New cards

Why may a blower operate during an A2L leak?

To dilute the refrigerant concentration.

79
New cards

What is miscibility?

Ability of refrigerant and oil to mix.

80
New cards

What does hygroscopic mean?

Ability to absorb moisture from air.

81
New cards

What is hydrolysis?

Reaction involving water that can degrade POE oil and produce acids and sludge.

82
New cards

What is mineral oil (MO)?

Petroleum-derived oil containing wax, used mainly with CFCs and some HCFCs.

83
New cards

What is alkylbenzene oil (AB)?

Synthetic wax-free oil used in certain R-22 and retrofit applications.

84
New cards

What is polyol ester oil (POE)?

Very hygroscopic synthetic oil commonly used with HFCs and HFOs.

85
New cards

What is polyvinyl ether oil (PVE)?

Synthetic oil used in some HFC systems that does not undergo POE-type hydrolysis.

86
New cards

What is polyalkylene glycol oil (PAG)?

Extremely hygroscopic oil primarily used in automotive air conditioning.

87
New cards

What is polyalkylene glycol oil (PAG) primarily used for?

Automotive air conditioning.

88
New cards

What is the recommended oil exposure time?

Approximately 15 minutes.

89
New cards

Can evacuation remove all moisture from heavily contaminated oil?

Not necessarily; contaminated oil may require replacement.

90
New cards

What gas is used for pressure testing?

Dry nitrogen.

91
New cards

Why is dry nitrogen used for pressure testing?

It is an inert gas.

92
New cards

How is leak-test pressure determined?

Use the lowest applicable component test-pressure limit and manufacturer instructions.

93
New cards

What can a pressure drop during leak testing indicate?

A leak, after accounting for temperature changes.

94
New cards

What is the right gauge on the nitrogen regulator?

Tank pressure.

95
New cards

What is the left gauge on the nitrogen regulator?

Outlet pressure.

96
New cards

What are the four leak detection methods?

Ultrasonic detector, bubble solution, trace gas, and electronic leak detector.

97
New cards

What is the flammable refrigerant trace-gas limit?

25% of the lower flammability limit.

98
New cards

What is the response to a flammable refrigerant leak?

Vacate, safely ventilate, and verify the area is safe before service.

99
New cards

What is recovery in refrigerant handling?

Removing refrigerant from a system and storing it in an approved cylinder.

100
New cards

What is recycling in refrigerant handling?

Cleaning recovered refrigerant for permitted reuse.