Standard Solutions, Measurement Errors, and Titration

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/12

flashcard set

Earn XP

Description and Tags

Vocabulary flashcards covering the preparation of standard solutions, experimental measurement errors, resolution, and laboratory titration techniques.

13 Terms

1
New cards

Weigh by difference

A method to accurately determine mass by weighing the weighing boat before adding solid, weighing it with the solid, and weighing it again after the solid has been transferred.

2
New cards

Standard solution steps

  1. Weigh mass (weigh by difference / washings)

  2. Transfer to beaker + add distilled water

  3. Transfer to volumetric flask with funnel , rinse stirring rod, beaker, funnel distilled water, make solution up to mark with distilled water

  4. Shake + invert


3
New cards

Washings

Distilled water sprayed onto equipment (such as the weighing boat, stirring rod, funnel, and beaker) to rinse and transfer all residual solid or solution into the volumetric flask.

4
New cards

Inverting a volumetric flask

Placing a thumb on the stopper or lid and turning the flask upside down repeatedly to eliminate concentration gradients and ensure a homogenous concentration.

5
New cards

Error in reading

An error occurring from a single reading (1×1\times error), equal to ±12\text{±}\frac{1}{2} the smallest increment on manual equipment or ±\text{±} the smallest increment on electronic equipment (e.g., mass).

6
New cards

Error in measurement

An error resulting from taking two readings (e.g., at the start and end, giving 2×2\times error), calculated as 2×±122 \times \text{±}\frac{1}{2} smallest increment for manual equipment or 2×±2 \times \text{±} smallest increment for digital equipment (e.g., weigh by difference, titre, temperature change).

7
New cards

Equipment range

The span of values that a piece of equipment can measure (e.g., a beaker with a total capacity of 150150 whose scale only reads up to 120120, giving a range of 0−120 ml0 - 120\text{ ml}).

8
New cards

Resolution

The smallest change in measurement that an instrument can detect.

9
New cards

Rough titration

The initial titration performed to find approximately how much titrant is needed, stopped upon reaching the peach/orange endpoint colour.

10
New cards

Concordant results

Titre readings that are within 0.1 cm30.1\text{ }cm^3 of each other, used to calculate the mean titre.

11
New cards

White tile

A tile placed directly underneath the conical flask during a titration to ensure the true colour of the solution and endpoint is clearly seen.

12
New cards

Titration instructions

  1. Rinse glass pipette with NaOH, put in conical flask on white tile

  2. Rinse biuret acid, fill up to eye level , open to release air bubble

  3. Add HCl, until endpoint rough

  4. Repeat then when get close do drop by drop, rinse tip biuret with distilled water + sides conical flask after each drop


13
New cards

Removing air bubble in burette

Opening the tap once filled above the 00 mark to allow acid to flow down until the meniscus rests exactly on the 00 line, expelling any trapped air bubbles.