1/19
Looks like no tags are added yet.
As the distance increases, the beam quantity reaching a specific area
Decreases
X-rays are produced by
characteristic and bremsstrahlung interactions
The primary source of radiation exposure to the radiographer who is in the room during an exposure is
from scatter from the patient.
Which of the following is the primary factor controlling quantity?
mAs
Photoelectric interactions
contribute significantly to patient dose.
A filament electron removes a K shell electron and an M shell electron fills the vacancy. The K shell binding energy is 69.5 keV and the M shell binding energy is 2.8 keV. What is the energy of the K-characteristic photon produced?
66.7 keV
The fog seen on the radiographic image is the result of
Compton interactions.
Secondary photons produced during a Compton interaction
contribute to patient dose
Bremsstrahlung means
Braking radiation
To minimize occupational exposure, the technologist should
wear protective apparel (lead aprons, gloves, etc.) when in the room during imaging.
Classical interactions are also known as
Thomson and coherent scattering.
Radiation interacting with air is more likely to be _____________, resulting in that area of the image being darker.
transmitted
When filament electrons enter the anode target, they interact with
outer shell electrons of tungsten atoms.
When it does interact with the image receptor, the Compton scatter photon contributes no useful information bec
it has changed direction
The energy of the brems photon depends on
all of these.
With Compton scattering, the incident photon
loses up to one third of its energy
When a filament electron knocks out a K shell electron from the tungsten atom, it leads to
a characteristic x-ray photon.
The majority of the x-ray photons produced are
brems photons.
Coherent scattering involves
an x-ray photon with low energy.
The energy of the characteristic x-ray photon depends on
all of these