Wavelength
Distance between two successive peaks, expressed in nanometers (nm).
Frequency
Number of vibrations of wave motion per second.
Planck's Formula
Describes the inverse relationship between wavelength, frequency, and energy (E).
Visible Spectrum
The region of the electromagnetic spectrum spanning 400 to 700 nm.
Ultraviolet Region (UV)
The region of the electromagnetic spectrum with wavelengths less than 400 nm.
Infrared Region
The region of the electromagnetic spectrum with wavelengths greater than 700 nm.
Spectrophotometry
Measurement of light transmitted by a solution to determine the concentration of light-absorbing substances.
Single-beam Spectrophotometer
Simplest type of spectrophotometer designed to make one measurement at a time at one specified wavelength.
Double-beam in Space
Spectrophotometer design that splits light and uses two photodetectors to measure sample and reference simultaneously.
Double-beam in Time
Spectrophotometer design that splits light but uses only one photodetector with a chopper to measure over time.
Continuum Source
Light source that emits radiation that changes continuously in intensity (e.g., tungsten, deuterium, xenon).
Tungsten Light Bulb
Most commonly used light source for visible and near-infrared spectrophotometry.
Deuterium Lamp
Light source routinely used to provide UV radiation down to 165 nm.
Xenon Discharge Lamp
Light source that covers both UV and visible light spectra.
Line Source
Light source emitting limited radiation and wavelength, such as a hollow cathode lamp or laser.
Entrance Slit
Component that minimizes unwanted stray light and prevents scattered light from entering the monochromator.
Stray Light
Wavelengths outside the transmitted band that do not originate from the light source and cause absorbance errors.
Diffraction Gratings
Most commonly used monochromator, made by cutting grooves or slits into an aluminized flat piece of crown glass.
Exit Slit
Controls the width of the light beam (bandpass), allowing only a narrow fraction of the spectrum to reach the cuvette.
Bandpass
The total range of wavelengths transmitted by the exit slit of a monochromator.
Alumina Silica Glass Cuvette
Most commonly used cuvette type, suitable for wavelengths from 350 nm to 2000 nm.
Quartz / Plastic Cuvette
Cuvette type required for solutions measured in the ultraviolet spectrum.
Photodetector
Component that detects transmitted light and converts it into photoelectric energy.
Photomultiplier Tube (PMT)
The most sensitive photodetector type, which amplifies the initial electronic signal.
Photodiode
Photodetector that is not as sensitive as PMT but features excellent measurement linearity.
Didymium / Holmium Oxide Filter
Filter used to monitor and check the wavelength accuracy of a spectrophotometer.
Neutral Density Filter / Dichromate
Used to verify the photometric linearity of a spectrophotometer.
Beer's Law
Concentration of an unknown is directly proportional to absorbed light and inversely proportional to transmitted light.
Reagent Blank
Blanking technique that subtracts the inherent color of the reagents from each unknown reading.
Sample Blank
Blanking technique that corrects for optical interferences by measuring sample and reagent without the end product.
Flame Emission Photometry
Measures light emitted by excited electrons returning to ground state using a flame as both source and cuvette.
Indirect Internal Standard Method
Flame photometry method utilizing lithium or cesium as internal standards to minimize variations.
Atomic Absorption Spectrophotometry
Measures light absorbed by ground-state, unexcited atoms dissociated from chemical bonds by heat.
Hollow-cathode Lamp
The specialized light source used in atomic absorption spectrophotometry.
Turbidimetry
Determines the amount of light blocked by particulate matter suspended in a turbid solution.
Nephelometry
Determines the amount of scattered light (at an angle) by particulate matter in a turbid solution.
Fluorometry
Measures light emitted by a molecule after excitation over a zero background, using primary and secondary filters.
Chemiluminescence
Chemical reaction yielding an electronically excited compound that emits light as it returns to its ground state.
Freezing Point Depression Osmometry
Measures osmolality by supercooling a solution and detecting the stable temperature depression caused by solute particles.
Thermistor
The temperature-sensing device used in osmometry to detect the exact freezing point of the sample.
Electrophoresis
Migration and separation of charged particles (such as proteins) in an electric field based on charge densities.
Cellulose Acetate
Electrophoretic support medium that separates proteins primarily by molecular size.
Agarose Gel
Electrophoretic support medium separating by electrical charge that does not bind protein.
Polyacrylamide Gel
Electrophoretic medium separating by charge and size, dividing proteins into 20 fractions; used to study isoenzymes.
Densitometry
Measures the absorbance of electrophoresis stains to scan and quantitate individual protein bands.
Isoelectric Focusing
Separates molecules by migrating them through a pH gradient until they reach their neutral charge point.
Capillary Electrophoresis
Separation of molecules inside a fused silica capillary driven by electro-osmotic flow.
Potentiometry
Electrochemistry measuring electrical potential differences (voltage) between a reference and measuring electrode.
Nernst Equation
Mathematical equation used in potentiometry to calculate ion concentration from measured potential difference.
Saturated Calomel Electrode
Reference electrode consisting of mercury in contact with a solution saturated with mercurous chloride.
Silver-silver Chloride Electrode
Reference electrode ideal for high temperatures above 60 degrees Celsius.
Severinghaus Electrode
Modified pH electrode contained in a sodium bicarbonate jacket with a gas-permeable membrane to measure pCO2.
Direct ISE
Ion-selective electrode assay performing measurements directly on undiluted patient serum.
Indirect ISE
Ion-selective electrode assay requiring dilution of patient serum (usually 1:16 to 1:34) before measurement.
Coulometry
Electrochemistry measuring the quantity of electricity at a fixed potential, following Faraday's Law.
Amperometry
Electrochemistry measuring current flow produced by an oxidation-reduction reaction at a constant voltage.
Clark Electrode
Amperometric polarographic electrode used to measure partial pressure of oxygen (pO2).
Voltametry
Measures current after applying potential, allowing sample preconcentration to detect minimal analyte levels.
Chromatography
Separation of soluble components using physical-chemical differences between a mobile and stationary phase.
Retention Time
The time required for an analyte to travel through a chromatographic column, used for qualitative identification.
Area Under the Peak
The chromatographic metric used to measure and quantitate the concentration of an analyte.
Gas Chromatography (GC)
Separation of volatile compounds using inert carrier gases (helium, nitrogen, hydrogen, argon) as the mobile phase.
Reversed-Phase HPLC
Liquid chromatography style with a nonpolar stationary phase (C-18) and a polar mobile phase.
Size Exclusion Chromatography
Separates molecules based on size and shape, where larger molecules elute rapidly from the column first.
Mass Spectrometry (MS)
Fragments and ionizes molecules, plotting components by mass-to-charge (m/z) ratio and relative abundance.
Proteomics
Study of proteins to identify potential disease biomarkers for clinical diagnosis.
Metabolomics
Study measuring the concentration of very small metabolites using separation and mass-to-charge ratios.
MALDI-TOF MS
Separates ionized samples through a time-of-flight tube to measure travel time to the detector.
Point-of-Care Testing (POCT)
Near-patient, bedside, or decentralized clinical testing performed outside the lab, typically by non-laboratorians.
Continuous Flow Analyzer
Automated system pumping liquids through continuous tubing, running sequential panels on all samples sharing a pathway.
Centrifugal Analyzer
Automated system using centrifugal force to spin specimens and reagents into separate matched perimeter cuvettes.
Discrete Analyzer
Most popular and versatile automated system, using random access to run only requested tests one-at-a-time per sample.
Open Reagent System
Automated analyzer allowing the use of reagents from third-party manufacturers.
Closed Reagent System
Automated analyzer restricting the operator to use only the manufacturer's proprietary reagents.
Master Lot
Calibration information embedded in barcoded reagent labels, containing curves, expectancies, and tolerances.
Middleware
Central software hub consolidating data and interactions from all instruments onto a single technologist display.
Physical Workcell
A cluster of clinical laboratory devices physically connected by a track with a single sample loading area.
Virtual Workcell
A cluster of clinical laboratory devices connected digitally via middleware instead of fingerprints physically by a track.