PLAX - Diastole
Measurements must be perpendicular to chamber walls
End-diastole: onset of the QRS, first frame after MV closure or frame in which the cardiac chamber is largest
All valves closed
Taken at the MV leaflet tips
**If there is a sigmoidal septum, move towards apex to avoid it
**Do not include RV in IVS
IVSd
LVIDd
LVPWd

PLAX - Systole
Measurements must be perpendicular to chamber walls
End-systole: frame after AV closure or the time in when cardiac chamber is smallest, around the T wave
All valves closed
Taken at the MV leaflet tips
LVIDs

Zoomed AV
Measurements must be perpendicular to LVOT walls taken inner edge to inner edge
Mid-systole: AV open
LVOT: should be taken 5-10 mm proximal to the annulus
AoV open
LVOT
Aortic Annulus

Zoomed Aortic Root
Normal Aortic size in the adult:
Ao root < 4.0 cm
Ascending Ao < 3.7 cm
Descending Aorta < 2.8 cm
***These values can vary considerably depending on age, gender, and body habitus***
Measurements must be perpendicular to aorta walls taken leading edge to leading edge
End-diastole: onset of the QRS or frame before AV opens
Right before AV opens
Aortic Sinus/Sinus of Valsalva
STJ
Ascending Aorta

High PLAX Asc Aorta
Measurements must be perpendicular to aorta walls taken leading edge to leading edge
End-diastole: onset of the QRS or frame before AV opens
Ascending Aorta

Ao measurements

IVC Diameter
Measurement must be perpendicular to IVC walls and taken inner edge to inner edge
~1-2 cm proximal to IVC/RA junction
Measured when IVC is at its maximum/biggest dimension
IVC normal size is < 2.1 cm

A4CH RV Focused TAPSE (tricuspid annular planar systolic excursion) Measurement
M-mode cursor should be aligned along the RV free wall as perpendicular to the lateral tricuspid annulus as possible (and as parallel as possible to movement of the TV annulus)
Measure leading edge of TV annulus from end-diastole toward the apex at end-systole
Normal TAPSE value >1.7 cm otherwise systolic dysfunction

IVC Sniff Test
M-mode cursor is placed through the IVC ~1-2 cm distal from the hepatic vein, then have the patient perform a sniff maneuver
IVC diameter should be ≤ 2.1cm

Protocol
PLAX
IVSd
LVIDd
LVPWd
LVIDs
PLAX (m-mode)
LV (@MV tips)
MV (@MV tips)
AV (@AV tips)
Zoomed AV
LVOT diameter
Ao Annulus
Ao Sinus
Ao STJ
Asc Ao
A4C
TAPSE
SUBX
IVC diameter
IVC m-mode sniff
bonus
LV M-Mode (at MV leaflet tips)
IVSd
LVIDd
LVPWd
LVIDs
AV M-Mode (aortic leaflet tips)
Aortic diameter (QRS, leading to leading)
LA diameter (just after T wave, biggest LA, leading to leading)