What does the bleeding time measure
Platelet function and Vascular integrity
How is the time measured (bleeding time)
Blotting blood from an incision made on the arm, every 30 seconds
What does the sphygmomanometer need to be set on when performing a bleeding time
40 mmHg
Patients should not have bleeding times if their platelet counts are below what
50,000 cells/uL
Bleeding times should be performed directly over a vein. True/False
False
How is the patient's arm prepped for the bleeding time test?
With an alcohol prep pad and allow to air dry
How far below the bend of the arm is the incision for a bleeding time to be made
5 cm
What is used to collect the specimen
Filter Paper
What is the expected result of a normal patient (bleeding time)
2-7 minutes
Patients on Aspirin could have falsely increased results (bleeding time)
True
What is the additive in the tube used to ensure clotting (FDP)
Thrombin
What additive prevents clot lysis in the sample tube (FDP)
Soy bean trypsin
What type of test is being performed for this lab procedure (FDP)
Latex agglutination
We should be testing on a pure serum sample; no red cells should be present. True/False. (FDP)
True
How many minutes is the card to be rocked to mix the specimen (FDP)
3 minutes
What two dilutions should be made for testing (FDP)
1:10, 1:40
What reaction indicates a positive response (FDP)
clumping
Positive FDP results are seen in the following conditions except:
DIC
Primary Fibrin(ogeno)lysis
Post thrombotic therapy
A cold virus
A cold virus
Any disorder that has excessive clotting will have an increased FDP level. True/False
True
What is the unit of measurement for the fibrinogen assay?
Mg/dl
What is being converted from the result you obtain from testing (Quanitative Fibrinogen Determination)
seconds to concentration
The relationship between your test result and the conversion is inversely proportional. True/False. (Quanitative Fibrinogen Determination)
True
The reagent used in this procedure is? (Quanitative Fibrinogen Determination)
Thrombin
The specimen should be serum to be tested. True/False. (Quanitative Fibrinogen Determination)
False
What is the max time testing must be performed in? (Quanitative Fibrinogen Determination)
2 hours
What dilutions should be with the patient sample for testing (Quanitative Fibrinogen Determination)
1:10
What is the expected range for fibrinogen
(Quanitative Fibrinogen Determination)
170-410 mg/dl
What factor converts fibrinogen to fibrin
Thrombin
Fibrinogen is a negatively charged molecule. True/False
True
What tube type is required for coagulation testing
Sodium Citrate
What is the difference between plasma and serum
serum does not have clotting factors and plasma does
Protime is a test that measure which pathway
Extrinsic
Which of the following factors is not measured by the Protime test:
VIII
X
V
I
VIII
What impedance does a Fibrometer use
electrical
What impedance does a KC1 Delta use
mechanical
What medication is monitored by the PT test
Coumadin-Warfarin
The activity of which factors are measured by Protime
X, VII, V, II, I
The reagent includes tissue thromboplastin which is the in vitro equivalent to what in vivo component
TF3
Calcium is included in the reagent. True/False. (PT)
True
How long should the reagent and patient sample be warmed in the warmer of the Fibrometer?
3 minutes
The ISI value included in the package insert for thromboplastin reagent is specific to each lot. True/False
True
The INR value is the ratio calculated using the ISI in the package insert; to normalize the result regardless of instrumentation used to analyze the specimen. True/False
True
The purpose of this test is to determine if an abnormal PT/APTT result is caused by a factor deficiency or circulating inhibitor. True/False. (mixing)
True
What product can be added to correct a deficiency problem in a patient
Pooled Normal Plasma
What is the mixture used in this procedure? (mixing)
50:50
The reagents used for PT and APTT are still used in this procedure. True/False. (mixing)
True
Which procedure uses its own bottle of calcium chloride
APTT
It is okay to perform correction testing with both a PT and APTT. True/False
False
If the original specimen result was abnormal and the rerun with PNP normalizes the result, you can assume it is corrected. True/False
False
APTT is a test that measure which pathway
Intrinsic
What factors are not measured by the APTT test
VII and XIII
Which medication is monitored by the APTT
Heparin
This reagent comes paired with a bottle of CaCl2 which must be changed together. True/False
True
On the KC1 Delta, how many seconds will the sample and reagent need to incubate together before CaCl2 is added
180 seconds
What factor does Heparin bind to and inactivate
IIa
What factor needs to be activated to start the coagulation cascade
XII
Which substance found in APTT reagents, is used to initiate the clotting process
Kaolin
APTT testing on the Fibrometer requires using stir sticks to mix the patient and the reagent together, where it is not required on the KC1 Delta because it is mixed as the cup rotates. True/False
True
CaCl2 is added to start the clotting process for APTT. True/False
True