PA Hand: Image Criteria

  • Look at proximal phalanx, MC shafts and heads

  • Proximal phalanx and metacarpals are concave on the anterior aspect

  • Check for open joints

  • Abducted thumb


<ul><li><p>Look at proximal phalanx, MC shafts and heads</p></li><li><p>Proximal phalanx and metacarpals are concave on the anterior aspect</p></li><li><p>Check for open joints</p></li><li><p>Abducted thumb</p></li></ul><p></p>
2
New cards
<p>PA Hand: What is wrong here &amp; how do we fix it?</p>

PA Hand: What is wrong here & how do we fix it?

  • Unequal midshaft concavity on either side of the phalanges and MCs

    • Abduct 1st digit away from 2nd digit

  • Uneven spacing of the MC heads

  • Slight external rotation

    • Internally rotate hand until palm and fingers are flat


3
New cards
<p>PA Hand: What is wrong here &amp; how do we fix it?</p>

PA Hand: What is wrong here & how do we fix it?

  • Hands and fingers are flexed

  • IP and CM joints are closed; phalanges and MCs are foreshortened. Thumb is lateral.

    • Extend the patient’s hand and fingers; place them flat against the IR (if condition allows)


4
New cards

PA Oblique Hand: Image Criteria

  • Check the phalanx/MC shafts, spacing of the MC heads and joints

  • Slight superimposition & separation of 3-5 metacarpals

  • Open joint spaces

  • Fingers parallel with the IR


<ul><li><p>Check the phalanx/MC shafts, spacing of the MC heads and joints</p></li><li><p>Slight superimposition &amp; separation of 3-5 metacarpals</p></li><li><p>Open joint spaces</p></li><li><p>Fingers parallel with the IR</p></li></ul><p></p>
5
New cards
<p>PA Oblique Hand: What is wrong here &amp; how do we fix it?</p>

PA Oblique Hand: What is wrong here & how do we fix it?

  • Midshafts of 3rd-5th MCs superimposed

    • More than 45 degrees obliqued

  • Phalanges foreshorten, IP jts closed

    • Fingers are not parallel to IR

Internally rotate hand to a 45-degree angle and extend fingers until parallel with IR.


6
New cards

Lateral Hand (Fan): Image Criteria

  • Check MC shafts (should be stacked on each other)

  • Joint space open

  • Radius and Ulna are seen

  • Phalanges extended/separated and not superimposed


<ul><li><p>Check MC shafts (should be stacked on each other)</p></li><li><p>Joint space open</p></li><li><p>Radius and Ulna are seen</p></li><li><p>Phalanges extended/separated and not superimposed</p></li></ul><p></p>
7
New cards
<p>Lateral Hand: What is wrong here &amp; how do we fix it?</p>

Lateral Hand: What is wrong here & how do we fix it?

  • 2-5 MC midshafts are not superimposed, and the shortest (5th) MC is anterior to 3-4

  • Hand was externally rotated

Internally rotate the hand until the MCs are superimposed.


8
New cards

If the distal interpalangeal joints are closed on the PA Hand radiograph, the distal phalanges are probably going to be _________________ on the radiograph.

foreshortened

9
New cards

PA Wrist: Image Criteria

  • Check for superimposition of carpals and radioulnar joint (should have joint space)


<ul><li><p>Check for superimposition of carpals and radioulnar joint (should have joint space)</p></li></ul><p></p>
10
New cards
<p>PA Wrist: What is wrong here &amp; how do we fix it?</p>

PA Wrist: What is wrong here & how do we fix it?

  • Lateral carpals and Mcs are overly superimposed

  • Radioulnar jt is closed

  • Slight internal rotation

Rotate the wrist externally until PA (making a fist helps too).


11
New cards

Lateral Wrist: Image Criteria

  • Check scaphoid, pisiform, radius, and ulna

  • Radius and ulna should be superimposed


<ul><li><p>Check scaphoid, pisiform, radius, and ulna</p></li><li><p>Radius and ulna should be superimposed</p></li></ul><p></p>
12
New cards
<p>Lateral Wrist: What is wrong here &amp; how do we fix it?</p>

Lateral Wrist: What is wrong here & how do we fix it?

  • Anterior aspect of the distal scaphoid is anterior to the anterior aspect of the pisiform

  • Radius is anterior to the ulna

  • Wrist was internally rotated

    • Externally rotate the wrist until the wrist is in a lateral position


13
New cards

On a lateral wrist, if the ulna goes back and radius goes forward, which kind of rotation occurred?

Internal rotation

14
New cards

On a lateral wrist, if the ulna goes forward and the radius goes back, which kind of rotation occurred?

External rotation

15
New cards

AP Elbow: Image Criteria

  • Check radial heads and epicondyles

  • Epicondyles should be parallel to IR


<ul><li><p>Check radial heads and epicondyles</p></li><li><p>Epicondyles should be parallel to IR</p></li></ul><p></p>
16
New cards
<p>Is this image a Left elbow?</p>

Is this image a Left elbow?

Yes, this is a left elbow x-ray

17
New cards
<p>AP Elbow: What is wrong here &amp; how do we fix it?</p>

AP Elbow: What is wrong here & how do we fix it?

  • Humeral epicondyles are not in profile

  • About ½ the radial head is superimposed over the ulna

  • Elbow was medially rotated

Rotate elbow externally until the humeral epicondyles are parallel with IR.


18
New cards

AP Oblique Elbow (External Rotation): Image Criteria

  • Check radial head and tuberosity, joint space should be seen


<ul><li><p>Check radial head and tuberosity, joint space should be seen</p></li></ul><p></p>
19
New cards
<p>AP External Oblique Elbow: What is wrong here &amp; how do we fix it?</p>

AP External Oblique Elbow: What is wrong here & how do we fix it?

  • The radial head and tuberosity are partially superimposed over the ulna

  • < 45 degrees

Rotate externally until the humeral epicondyles are 45 degrees to IR.


20
New cards

Lateral Elbow: Image Criteria

  • Radial head superimposed with coronoid process, stacked epicondyles


<ul><li><p>Radial head superimposed with coronoid process, stacked epicondyles</p></li></ul><p></p>
21
New cards
<p>Lateral Elbow: What is wrong here &amp; how do we fix it?</p>

Lateral Elbow: What is wrong here & how do we fix it?

  • Elbow joint is closed and radial head is positioned too far posteriorly on the coronoid process

  • Should was elevated above elbow

Lower the humerus until the epicondyles are perp. to IR and the humerus is parallel with IR


22
New cards

AP Shoulder (External): Image Criteria

  • Greater tubercle visualized in profile

  • CR 1” inferior to coracoid process

  • Superior scapular angle is superimposed on clavicle

  • Glenoid cavity is angled forward


<ul><li><p>Greater tubercle visualized in profile</p></li><li><p>CR 1” inferior to coracoid process</p></li><li><p>Superior scapular angle is superimposed on clavicle</p></li><li><p>Glenoid cavity is angled forward</p></li></ul><p></p>
23
New cards
<p>AP Shoulder (External): Is this Image Good?</p>

AP Shoulder (External): Is this Image Good?

  • Superior scapular angle is demoed superior to the midclavicle

  • Scapular body longitudinally foreshortened

  • Patient was leaned forward (MCP tilted anteriorly)

    • Have patient straighten MCP


24
New cards

AP Shoulder (Internal): Image Criteria

  • Lesser tubercle visualized in full profile

  • CR 1” inferior to coracoid process

  • Superior scapular angle is superimposed on the clavicle


<ul><li><p>Lesser tubercle visualized in full profile</p></li><li><p>CR 1” inferior to coracoid process</p></li><li><p>Superior scapular angle is superimposed on the clavicle</p></li></ul><p></p>
25
New cards
<p>AP Shoulder (Internal): Is this Image Good?</p>

AP Shoulder (Internal): Is this Image Good?

  • Incorrect centering that cuts off some of proximal humerus

    • Needs to be 1” below coracoid process

  • Lesser tubercle not in profile, incorrect rotation of upper limb

    • Have patient turn arm until back of hand is on leg


26
New cards
<p>AP Shoulder (Internal): Is this Image Good?</p>

AP Shoulder (Internal): Is this Image Good?

  • Shoulder is rotated toward the affected side (toward IR)

  • Glenoid cavity is too narrow, almost in profile and is almost a Grashey

    • Rotate affected shoulder away from IR, placing patient flat/parrallel to IR


27
New cards

Shoulder Lawrence Method

  • Superimposed superior and inferior glenoid rims (straight line)

  • CR directed to joint

  • Hand supinated (lesser tubercle on top)


<ul><li><p>Superimposed superior and inferior glenoid rims (straight line)</p></li><li><p>CR directed to joint</p></li><li><p>Hand supinated (lesser tubercle on top)</p></li></ul><p></p>
28
New cards
<p>Shoulder Lawrence: Is this Image Good?</p>

Shoulder Lawrence: Is this Image Good?

  • Tubercle is good

  • Glenohumeral jt is closed, and the glenoid cavity margins are separated with inferior rim lateral to superior rim.

  • Insufficient angle between the lateral body surface and the CR

    • Increase angle between the lateral body surface and the CR to 25-30 degrees


29
New cards
<p>Shoulder Lawrence: Is this Image Good?</p>

Shoulder Lawrence: Is this Image Good?

  • Lesser tubercle is not fully in profile and anterior

    • Supinate the hand


30
New cards
<p>Shoulder Lawrence: Is this Image Good?</p>

Shoulder Lawrence: Is this Image Good?

  • Tubercle is good

  • Insufficient CR angle and IR placement (too far from neck) les to cut-off os shoulder girdle

    • Increase angle between the lateral body surface and the CR to 25-30 degrees to capture more shoulder girdle

    • Make sure IR is aligned perp. to the CR

  • Too much scatter, decreased contrast (too grayed out)

    • Use a grid and increase mAs


31
New cards

Scapular Y Shoulder: Image Criteria

  • Coracoid is close to ribs/skimming it

  • Glenoid cavity/fossa is on end


<ul><li><p>Coracoid is close to ribs/skimming it</p></li><li><p>Glenoid cavity/fossa is on end</p></li></ul><p></p>
32
New cards
<p>Scap Y Shoulder: Is this Image Good?</p>

Scap Y Shoulder: Is this Image Good?

  • Medial and lateral borders of scapula are not superimposed (medial border in ribs)

  • Coracoid process is far away from ribs

  • Humeral head not superimposed directly over glenoid cavity, shifted lateral

  • Under-rotation of affected shoulder

    • Increase rotation of the affected shoulder away from IR


33
New cards
<p>Scap Y Shoulder: Is this Image Good?</p>

Scap Y Shoulder: Is this Image Good?

  • Medial and lateral borders of scapulas are not superimposed (lateral border in ribs)

  • Coracoid process is lost inside the ribs

  • Humeral head not superimposed directly over glenoid cavity, humerus too far anterior

  • Over-rotation of affected shoulder

    • Decrease rotation of the affected shoulder back toward IR